-
Low-loss liquid metal interconnects for superconducting quantum circuits
Authors:
Zhancheng Yao,
Martin Sandberg,
David W. Abraham,
David J. Bishop
Abstract:
Building a modular architecture with superconducting quantum computing chips is one of the means to achieve qubit scalability, allowing the screening, selection, replacement, and integration of individual qubit modules into large quantum systems. However, the nondestructive replacement of modules within a compact architecture remains a challenge. Liquid metals, specifically gallium alloys, can be…
▽ More
Building a modular architecture with superconducting quantum computing chips is one of the means to achieve qubit scalability, allowing the screening, selection, replacement, and integration of individual qubit modules into large quantum systems. However, the nondestructive replacement of modules within a compact architecture remains a challenge. Liquid metals, specifically gallium alloys, can be alternatives to solid-state galvanic interconnects. This is motivated by their self-healing, self-aligning, and other desirable fluidic properties, potentially enabling the nondestructive replacement of modules at room temperatures, even after operating the entire system at millikelvin regimes. In this study, we present coplanar waveguide resonators (CPWRs) interconnected by gallium alloy droplets, achieving high internal quality factors up to nearly one million and demonstrating performance on par with the continuous solid-state CPWRs. Leveraging the desirable fluidic properties of gallium alloys at room temperature and their compact design, we envision a modular quantum system enabled by liquid metals.
△ Less
Submitted 27 June, 2024; v1 submitted 31 March, 2024;
originally announced April 2024.
-
Zeptonewton and Attotesla per Centimeter Metrology With Coupled Oscillators
Authors:
Ian Bouche,
Josh Javor,
Abhishek Som,
David K. Campbell,
David J. Bishop
Abstract:
We present the coupled oscillator: a new mechanism for signal amplification with widespread application in metrology. We introduce the mechanical theory of this framework, and support it by way of simulations. We present a particular implementation of coupled oscillators: a microelectromechanical system (MEMS) that uses one large (~100mm) N52 magnet coupled magnetically to a small (~0.25mm), oscil…
▽ More
We present the coupled oscillator: a new mechanism for signal amplification with widespread application in metrology. We introduce the mechanical theory of this framework, and support it by way of simulations. We present a particular implementation of coupled oscillators: a microelectromechanical system (MEMS) that uses one large (~100mm) N52 magnet coupled magnetically to a small (~0.25mm), oscillating N52 magnet, providing a force resolution of 200zN measured over 1s in a noiseless environment. We show that the same system is able to resolve magnetic gradients of 130aT/cm at a single point (within 500um). This technology therefore has the potential to revolutionize force and magnetic gradient sensing, including high-impact areas such cardiac and brain imaging.
△ Less
Submitted 22 May, 2024; v1 submitted 22 February, 2024;
originally announced February 2024.
-
Tuning the pH Response of Monolayer Hexagonal Boron Nitride/Graphene Field-Effect Transistors
Authors:
Nicholas E. Fuhr,
Mohamed Azize,
David J. Bishop
Abstract:
The chemical activity of ionized hydrogen describes the potency of protons in solution and is used to define the pH with wide-ranging applications in biological and materials sciences. Measuring pH with graphene field-effect transistors (FETs) has been described in the past but has yet to be characterized with a monolayer hexagonal boron nitride (hBN) cap** layer. hBN cap** is hypothesized to…
▽ More
The chemical activity of ionized hydrogen describes the potency of protons in solution and is used to define the pH with wide-ranging applications in biological and materials sciences. Measuring pH with graphene field-effect transistors (FETs) has been described in the past but has yet to be characterized with a monolayer hexagonal boron nitride (hBN) cap** layer. hBN cap** is hypothesized to lower the chemical affinity of protons to oxidized defects in the graphene crystal and lower the standard deviation of pH measurement via screening charge density. First, the electronic properties of commercial, monolayer graphene and monolayer hBN/graphene, both on four-inch 90 nm SiO2/p-type Si, were contrasted as a function of solutal pH in 10 mM phosphate buffered solution. The two-dimensional (2D) FETs were fabricated with photoresistless metallization followed by microcentrifuge tube-masking and reactive ion etching to define a quasi-pure 2D sensing mesa for pH sensing. Thereafter, the devices were exposed to phosphate buffer of varying pH and the resistance and liquid-transfer characteristics measured. The hBN/graphene/SiO2 FETs had higher linearity, and both lower standard deviation and range of Dirac voltage shifting than monolayer graphene/SiO2. Then, before microcentrifuge tube-masking, freshly metallized devices were coated with 9 nm of Al2O3 by electron beam deposition. The Al2O3/graphene/SiO2 and Al2O3/hBN/graphene/SiO2 devices showed an altered response to the pH of the phosphate buffered solutions before and after basic etching of the Al2O3 with NaOH (pH = 12). This prompted studying the pH-dependencies of the 2D devices as a function of the thickness of Al2O3 via atomic layer deposition. These results show that modifying the surface of monolayer graphene with nanoscale dielectrics enables tuning of the pH-dependent electronic properties of graphene pH sensors.
△ Less
Submitted 25 October, 2022;
originally announced October 2022.
-
Analysis of a Casimir-driven Parametric Amplifier with Resilience to Casimir Pull-in for MEMS Single-Point Magnetic Gradiometry
Authors:
Josh Javor,
Zhancheng Yao,
Matthias Imboden,
David K. Campbell,
David J. Bishop
Abstract:
The Casimir Force, a quantum mechanical effect, has been observed in several microelectromechanical systems (MEMS) platforms. Due to its extreme sensitivity to the separation of two objects, the Casimir Force has been proposed as an excellent avenue for quantum metrology. Practical application, however, is challenging due to attractive forces leading to stiction and failure of the device, called C…
▽ More
The Casimir Force, a quantum mechanical effect, has been observed in several microelectromechanical systems (MEMS) platforms. Due to its extreme sensitivity to the separation of two objects, the Casimir Force has been proposed as an excellent avenue for quantum metrology. Practical application, however, is challenging due to attractive forces leading to stiction and failure of the device, called Casimir pull-in. In this work, we design and simulate a Casimir-driven metrology platform, where a time-delay based parametric amplification technique is developed to achieve a steady state and avoid pull-in. We apply the design to the detection of weak, low frequency, gradient magnetic fields, similar to those emanating from ionic currents in the heart and brain. Simulation parameters are selected from recent experimental platforms developed for Casimir metrology and magnetic gradiometry, both on MEMS platforms. While MEMS offer many advantages to such an application, the detected signal must typically be at the resonant frequency of the device, with diminished sensitivity in the low frequency regime of biomagnetic fields. Using a Casimir-drive parametric amplifier, we report a 10,000 fold improvement in the best-case resolution of MEMS single-point gradiometers, with a maximum sensitivity of 6 Hz/(pT/cm) at 1 Hz. The development of the proposed design has the potential to revolutionize metrology, and specifically may enable unshielded monitoring of biomagnetic fields in ambient conditions.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Probing Subcellular Nanostructure of Engineered Human Cardiomyocytes in 3D Tissue
Authors:
Josh Javor,
Jourdan K. Ewoldt,
Paige E. Cloonan,
Anant Chopra,
Rebeccah J. Luu,
Guillaume Freychet,
Mikhail Zhernenkov,
Karl Ludwig,
Jonathan G. Seidman,
Christine E. Seidman,
Christopher S. Chen,
David J. Bishop
Abstract:
The structural and functional maturation of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is essential for application to pharmaceutical testing, disease modeling, and ultimately therapeutic use. Multicellular 3D-tissue platforms have improved functional maturation of hiPSC-CMs, but probing cardiac contractile properties remains challenging in a 3D environment, especially…
▽ More
The structural and functional maturation of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is essential for application to pharmaceutical testing, disease modeling, and ultimately therapeutic use. Multicellular 3D-tissue platforms have improved functional maturation of hiPSC-CMs, but probing cardiac contractile properties remains challenging in a 3D environment, especially at depth and in live tissues. Using small angle X-ray scattering (SAXS) images, we show that hiPSC-CMs, matured and examined in a 3D environment, exhibit periodic spatial arrangement of the myofilament lattice, which has not been previously detected in hiPSC-CMs. Contractile force is found to correlate with both scattering intensity (R2=0.44) and lattice spacing (R2=0.46). Scattering intensity also correlates with lattice spacing (R2=0.81), suggestive of lower noise in our structural measurement relative to the functional measurement. Notably, we observe decreased myofilament ordering in tissues with a myofilament mutation known to lead to hypertrophic cardiomyopathy (HCM). Our results highlight the progress of human cardiac tissue engineering and enable unprecedented study of structural maturation in hiPSC-CMs.
△ Less
Submitted 15 January, 2021;
originally announced January 2021.
-
Searching for the Casimir Energy
Authors:
Diego Pérez-Morelo,
Alexander Stange,
Richard W. Lally,
Lawrence K. Barrett,
Matthias Imboden,
David K. Campbell,
Vladimir A. Aksyuk,
David J. Bishop
Abstract:
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between…
▽ More
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between the two surfaces. In this new set of experiments, we aim to directly detect shifts in the Casimir $\textit{energy}$ in the vacuum due to the presence of metallic parallel plates, one of which is a superconductor. A change in the Casimir energy of this configuration is predicted to shift the superconducting transition temperature (T$_\textrm{c}$) because of an interaction between it and the superconducting condensation energy. The experiment we discuss consists of taking a superconducting film, carefully measuring its transition temperature, bringing a conducting plate close to the film, creating a Casimir cavity, and then measuring the transition temperature again. The expected shifts will be small, comparable to the normal shifts one sees in cycling superconducting films to cryogenic temperatures and so using a NEMS resonator and doing this in situ is the only practical way to obtain accurate, reproducible data. Using a thin Pb film and opposing Au surface, we observe no shift in T$_\textrm{c}$ greater than 12 $μ$K down to a minimum spacing of approximately 70 nm.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
100pTcm Sensitive MEMS Resonant Magnetometer from a Commercial Accelerometer
Authors:
Josh Javor,
Alexander Stange,
Corey Pollock,
Nicholas Fuhr,
David J. Bishop
Abstract:
Magnetic sensing is present in our everyday interactions with consumer electronics, and also demonstrates potential for measurement of extremely weak biomagnetic fields, such as those of the heart and brain. In this work, we leverage the many benefits of the micro-electromechanical systems (MEMS) devices to fabricate a small, low power, inexpensive sensor whose resolution is in the range of weak b…
▽ More
Magnetic sensing is present in our everyday interactions with consumer electronics, and also demonstrates potential for measurement of extremely weak biomagnetic fields, such as those of the heart and brain. In this work, we leverage the many benefits of the micro-electromechanical systems (MEMS) devices to fabricate a small, low power, inexpensive sensor whose resolution is in the range of weak biomagnetic fields. The sensor works at room temperature, and is suitable for consumer electronics integration. At present, such biomagnetic fields can only be measured by expensive mechanisms such as optical pum** and superconducting quantum interference devices (SQUIDs). Thus, our sensor suggests the opening of a large phase space for medical and consumer applications. The prototype fabrication is achieved by assembling micro-objects, including a permanent micromagnet, onto a post-release commercial MEMS accelerometer. With this system, we demonstrate a room temperature MEMS magnetometer, whose design is only sensitive to gradient magnetic fields and is generally insensitive to the Earth's uniform field. In air, the sensor's response is linear with a resolution of 1.1 nT cm-1 and spans over 3 decades of dynamic range to 4.6 μT cm-1. In 1 mTorr vacuum with 20 dB magnetic shielding, the sensor achieved 100 pT cm-1 resolution at resonance. The theoretical floor of this design is 110 fT cm-1 Hz-1/2 with a resolution of 13 fT cm-1, thus these devices hold promise for both magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
△ Less
Submitted 22 November, 2019;
originally announced November 2019.
-
Modeling and Thermal Metrology of Thermally Isolated MEMS Electrothermal Actuators for Strain Engineering of 2D Materials
Authors:
Mounika Vutukuru,
Jason W. Christopher,
Corey Pollock,
David J. Bishop,
Anna K. Swan
Abstract:
We present electrothermal microelectromechanical (MEMS) actuators as a practical platform for straining 2D materials. The advantages of the electrothermal actuator is its high output force and displacement for low input voltage, but its drawback is that it is actuated by generating high amounts of heat. It is crucial to mitigate the high temperatures generated during actuation for reliable 2D mate…
▽ More
We present electrothermal microelectromechanical (MEMS) actuators as a practical platform for straining 2D materials. The advantages of the electrothermal actuator is its high output force and displacement for low input voltage, but its drawback is that it is actuated by generating high amounts of heat. It is crucial to mitigate the high temperatures generated during actuation for reliable 2D material strain device implementation. Here, we implement a chevron actuator design that incorporates a thermal isolation stage in order to avoid heating the 2D material from the high temperatures generated during the actuation. By comparing experiment and simulation, we ensure our design does not compromise output displacement, while kee** the 2D material strain device stage cool. We also provide a simple analytical model useful for quickly evaluating different thermal isolation stage designs.
△ Less
Submitted 13 November, 2018;
originally announced November 2018.
-
Building a Casimir Metrology Platform with a Commercial MEMS Accelerometer
Authors:
Alexander Stange,
Matthias Imboden,
Josh Javor,
Lawrence K. Barrett,
David J. Bishop
Abstract:
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charg…
▽ More
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charged. In this paper we observe the Casimir Effect in ambient conditions using a modified capacitive MEMS accelerometer. Using a feedback assisted pick-and-place assembly process we are able to attach various micro-structures onto the post-release MEMS, converting it from an inertial force sensor to a direct force measurement platform with pN resolution. With this system we are able to directly measure the Casimir force between a silver-coated microsphere and gold-coated silicon plate. This device is a step towards leveraging the Casimir Effect for cheap, sensitive, room temperature quantum metrology.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
High Performance, Continuously Tunable Microwave Filters using MEMS Devices with Very Large, Controlled, Out-of-Plane Actuation
Authors:
Jackson Chang,
Michael Holyoak,
George Kannell,
Marc Beacken,
Matthias Imboden,
David J. Bishop
Abstract:
Software defined radios (SDR) in the microwave X and K bands offer the promise of low cost, programmable operation with real-time frequency agility. However, the real world in which such radios operate requires them to be able to detect nanowatt signals in the vicinity of 100 kW transmitters. This imposes the need for selective RF filters on the front end of the receiver to block the large, out of…
▽ More
Software defined radios (SDR) in the microwave X and K bands offer the promise of low cost, programmable operation with real-time frequency agility. However, the real world in which such radios operate requires them to be able to detect nanowatt signals in the vicinity of 100 kW transmitters. This imposes the need for selective RF filters on the front end of the receiver to block the large, out of band RF signals so that the finite dynamic range of the SDR is not overwhelmed and the desired nanowatt signals can be detected and digitally processed. This is currently typically done with a number of narrow band filters that are switched in and out under program control. What is needed is a small, fast, wide tuning range, high Q, low loss filter that can continuously tune over large regions of the microwave spectrum. In this paper we show how extreme throw MEMS actuators can be used to build such filters operating up to 15 GHz and beyond. The key enabling attribute of our MEMS actuators is that they have large, controllable, out-of-plane actuation ranges of a millimeter or more. In a capacitance-post loaded cavity filter geometry, this gives sufficient precisely controllable motion to produce widely tunable devices in the 4-15 GHz regime.
△ Less
Submitted 13 May, 2018; v1 submitted 23 April, 2018;
originally announced April 2018.
-
High speed control of electro-mechanical transduction Advanced Drive Techniques for Optimized Step-and-Settle Response of MEMS Micromirrors
Authors:
Matthias Imboden,
Jackson Chang,
Corey Pollock,
Evan Lowell,
Mehmet Akbulut,
Jessica Morrison,
Thomas Stark,
Thomas G. Bifano,
David J. Bishop
Abstract:
Micro/Nano Electro Mechanical Systems (MEMS/NEMS) provide the engineer with a powerful set of solutions to a wide variety of technical challenges. However, because they are mechanical systems, response times can be a limitation. In some situations, advanced engineered drive techniques can improve response times by as much as a thousand, significantly opening up the application space for MEMS/NEMS…
▽ More
Micro/Nano Electro Mechanical Systems (MEMS/NEMS) provide the engineer with a powerful set of solutions to a wide variety of technical challenges. However, because they are mechanical systems, response times can be a limitation. In some situations, advanced engineered drive techniques can improve response times by as much as a thousand, significantly opening up the application space for MEMS/NEMS solutions.
△ Less
Submitted 24 May, 2016; v1 submitted 15 December, 2015;
originally announced December 2015.
-
Design of a Casimir-driven parametric amplifier
Authors:
M. Imboden,
J. Morrison,
D. K. Campbell,
D. J. Bishop
Abstract:
In this paper, we discuss a design for a MEMS parametric amplifier modulated by the Casimir force. We present the theory for such a device and show that it allows for the implementation of a very sensitive voltage measuring technique, where the amplitude of a high quality factor resonator includes a tenth power dependency on an applied DC voltage. This approach opens up a new and powerful measurin…
▽ More
In this paper, we discuss a design for a MEMS parametric amplifier modulated by the Casimir force. We present the theory for such a device and show that it allows for the implementation of a very sensitive voltage measuring technique, where the amplitude of a high quality factor resonator includes a tenth power dependency on an applied DC voltage. This approach opens up a new and powerful measuring modality, applicable to other measurement types.
△ Less
Submitted 4 September, 2014; v1 submitted 12 April, 2014;
originally announced April 2014.