-
Intercomparison of micro- and nanodosimetry Monte Carlo simulations: an approach to assess the influence of different cross-sections for low-energy electrons on the dispersion of results
Authors:
Carmen Villagrasa,
Hans Rabus,
Giorgio Baiocco,
Yann Perrot,
Alessio Parisi,
Lara Struelens,
Rui Qiu,
Michael Beuve,
Floriane Poignant,
Marcin Pietrzak,
Heidi Nettelbeck
Abstract:
An intercomparison of microdosimetric and nanodosimetric quantities simulated Monte Carlo codes is in progress with the goal of assessing the uncertainty contribution to simulated results due to the uncertainties of the electron interaction cross-sections used in the codes. In the first stage of the intercomparison, significant discrepancies were found for nanodosimetric quantities as well as for…
▽ More
An intercomparison of microdosimetric and nanodosimetric quantities simulated Monte Carlo codes is in progress with the goal of assessing the uncertainty contribution to simulated results due to the uncertainties of the electron interaction cross-sections used in the codes. In the first stage of the intercomparison, significant discrepancies were found for nanodosimetric quantities as well as for microdosimetric simulations of a radiation source placed at the surface of a spherical water scoring volume. This paper reports insight gained from further analysis, including additional results for the microdosimetry case where the observed discrepancies in the simulated distributions could be traced back to the difference between track-structure and condensed-history approaches. Furthermore, detailed investigations into the sensitivity of nanodosimetric distributions to alterations in inelastic electron scattering cross-sections are presented which were conducted in the lead up to the definition of an approach to be used in the second stage of the intercomparison to come. The suitability of simulation results for assessing the sought uncertainty contributions from cross-sections is discussed and a proposed framework is described.
△ Less
Submitted 25 October, 2021; v1 submitted 18 August, 2021;
originally announced August 2021.
-
Consistency checks of results from a Monte Carlo code intercomparison for emitted electron spectra and energy deposition around a single gold nanoparticle irradiated by X-rays
Authors:
H. Rabus,
W. B. Li,
H. Nettelbeck,
J. Schuemann,
C. Villagrasa,
M. Beuve,
S. Di Maria,
B. Heide,
A. P. Klapproth,
F. Poignant,
R. Qiu,
B. Rudek
Abstract:
Organized by the European Radiation Dosimetry Group (EURADOS), a Monte Carlo code intercomparison exercise was conducted where participants simulated the emitted electron spectra and energy deposition around a single gold nanoparticle (GNP) irradiated by X-rays. In the exercise, the participants scored energy imparted in concentric spherical shells around a spherical volume filled with gold or wat…
▽ More
Organized by the European Radiation Dosimetry Group (EURADOS), a Monte Carlo code intercomparison exercise was conducted where participants simulated the emitted electron spectra and energy deposition around a single gold nanoparticle (GNP) irradiated by X-rays. In the exercise, the participants scored energy imparted in concentric spherical shells around a spherical volume filled with gold or water as well as the spectral distribution of electrons leaving the GNP. Initially, only the ratio of energy deposition with and without GNP was to be reported. During the evaluation of the exercise, however, the data for energy deposition in the presence and absence of the GNP were also requested. A GNP size of 50 nm and 100 nm diameter was considered as well as two different X-ray spectra (50 kVp and 100kVp). This introduced a redundancy that can be used to cross-validate the internal consistency of the simulation results. In this work, evaluation of the reported results is presented in terms of integral quantities that can be benchmarked against values obtained from physical properties of the radiation spectra and materials involved. The impact of different interaction cross-section datasets and their implementation in the different Monte Carlo codes is also discussed.
△ Less
Submitted 23 November, 2021; v1 submitted 15 May, 2021;
originally announced May 2021.
-
Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: assessing the uncertainty and correct methodology for extended beams
Authors:
H. Rabus,
W. B. Li,
C. Villagrasa,
J. Schuemann,
P. A. Hepperle,
L. de la Fuente Rosales,
M. Beuve,
S. Di Maria,
A. P. Klapproth,
C. Y. Li,
F. Poignant,
B. Rudek,
H. Nettelbeck
Abstract:
Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in th…
▽ More
Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in the order of several tens of micrometers from the GNP surface. As it has come to our attention that the figures in our paper have given rise to misinterpretation as showing 'the' DERs of GNPs under diagnostic X-ray irradiation, this article presents estimates of the DERs that would have been obtained with realistic radiation field extensions and presence of secondary particle equilibrium (SPE). These DER values are much smaller than those for a narrow-beam irradiation shown in our paper, and significant dose enhancement is only found within a few hundred nanometers around the GNP. The approach used to obtain these estimates required the development of a methodology to identify and, where possible, correct results from simulations whose implementation deviated from the initial exercise definition. Based on this methodology, literature on Monte Carlo simulated DERs has been critically assessed.
△ Less
Submitted 19 July, 2021; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Radiolysis of water confined in porous silica: A simulation study of the physicochemical yields
Authors:
H. Ouerdane,
B. Gervais,
H. Zhou,
M. Beuve,
J. -Ph. Renault
Abstract:
We investigate the radiolysis of liquid water confined in a porous silica matrix by means of an event-by-event Monte Carlo simulation of electron penetration in this composite system. We focus on the physical and physicochemical effects that take place in the picosecond range, before the radicals start to diffuse and react. We determine the radiolytic yields of the primary species for a system mad…
▽ More
We investigate the radiolysis of liquid water confined in a porous silica matrix by means of an event-by-event Monte Carlo simulation of electron penetration in this composite system. We focus on the physical and physicochemical effects that take place in the picosecond range, before the radicals start to diffuse and react. We determine the radiolytic yields of the primary species for a system made of cylindrical pores filled with water over a wide range of pore radii $R_{\rm C}$. We show that the relative position of the conduction band edge $V_0$ in both materials plays a major role in the radiolysis of composite systems. Due to its lower $V_0$ as compared to that of silica, water acts as a collector of low-energy electrons, which leads to a huge enhancement of the solvated electron yields for $R_{\rm C} \leq$ 100 nm. The confinement has also a marked effect on the spatial distribution of the radicals, which become isolated in a very large number of pores as $R_{\rm C}$ decreases.
△ Less
Submitted 27 December, 2016;
originally announced December 2016.
-
Statistical effects of dose deposition in track-structure modelling of radiobiology efficiency
Authors:
M. Beuve,
A. Colliaux,
D. Dabli,
D. Dauvergne,
B. Gervais,
G. Montarou,
E. Testa
Abstract:
Ion-induced cell killing has been reported to depend on the irradiation dose but also on the projectile parameters. In this paper we focus on two approaches developed and extensively used to predict cell survival in response to ion irradiation: the Local Effect Model and the Katz Model. These models are based on a track-structure description summarized in the concept of radial dose. This latter…
▽ More
Ion-induced cell killing has been reported to depend on the irradiation dose but also on the projectile parameters. In this paper we focus on two approaches developed and extensively used to predict cell survival in response to ion irradiation: the Local Effect Model and the Katz Model. These models are based on a track-structure description summarized in the concept of radial dose. This latter is sensitive to ion characteristics parameters and gives to both models the ability to predict some important radiobiological features for ion irradiations. Radial dose is however an average quantity, which does not include stochastic effects. These radiation-intrinsic effects are investigated by means of a Monte-Carlo simulation of dose deposition. We show that both models are not fully consistent with the nanometric and microscopic dose deposition statistics.
△ Less
Submitted 25 February, 2009;
originally announced February 2009.