Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter
Authors:
A. Apponi,
M. G. Betti,
M. Borghesi,
A. Boscá,
F. Calle,
N. Canci,
G. Cavoto,
C. Chang,
W. Chung,
A. G. Cocco,
A. P. Colijn,
N. D'Ambrosio,
N. de Groot,
M. Faverzani,
A. Ferella,
E. Ferri,
L. Ficcadenti,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
Y. Hochberg,
Y. Kahn
, et al. (31 additional authors not shown)
Abstract:
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the s…
▽ More
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.
△ Less
Submitted 24 January, 2022; v1 submitted 23 August, 2021;
originally announced August 2021.
-
Carbon nanotubes as anisotropic target for dark matter
Authors:
G Cavoto,
M G Betti,
C Mariani,
F Pandolfi,
A D Polosa,
I Rago,
A Ruocco
Abstract:
Directional detection of Dark Matter (DM) particles could be accomplished by studying either ion or electron recoils in large arrays of parallel carbon nanotubes. For instance, a MeV mass DM particle could scatter off a lattice electron, resulting in the transfer of sufficient energy to eject the electron from the nanotube surface. The electron can eventually be detected whenever an external elect…
▽ More
Directional detection of Dark Matter (DM) particles could be accomplished by studying either ion or electron recoils in large arrays of parallel carbon nanotubes. For instance, a MeV mass DM particle could scatter off a lattice electron, resulting in the transfer of sufficient energy to eject the electron from the nanotube surface. The electron can eventually be detected whenever an external electric field is added to drive it from the open ends of the array. This detection scheme would offer an anisotropic response and could be used to select an orientation of the target with respect to the DM wind. A compact sensor, in which the cathode element is substituted with a dense array of parallel carbon nanotubes, could serve as the basic detection unit which - if adequately replicated - would allow to explore a significant region of light DM mass and cross-section. A similar detection scheme could be used to detect DM particles with mass in the GeV range scattering off the surface of a CNT and ejecting a carbon ion. We report about the Monte Carlo simulations of such a system and the R&D towards a detector prototype.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.
-
A Design for an Electromagnetic Filter for Precision Energy Measurements at the Tritium Endpoint
Authors:
M. G. Betti,
M. Biasotti,
A. Bosca,
F. Calle,
J. Carabe-Lopez,
G. Cavoto,
C. Chang,
W. Chung,
A. G. Cocco,
A. P. Colijn,
J. Conrad,
N. D'Ambrosio,
P. F. de Salas,
M. Faverzani,
A. Ferella,
E. Ferri,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
J. Gudmundsson,
Y. Hochberg,
Y. Kahn
, et al. (26 additional authors not shown)
Abstract:
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential alon…
▽ More
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential along the mid-plane of the filter. As a function of drift distance along the length of the filter, the filter zooms in with exponentially increasing precision on the transverse velocity component of the electron kinetic energy. This yields a linear dimension for the total filter length that is exceptionally compact compared to previous techniques for electromagnetic filtering. The parallel velocity component of the electron kinetic energy oscillates in an electrostatic harmonic trap as the electron drifts along the length of the filter. An analysis of the phase-space volume conservation validates the expected behavior of the filter from the adiabatic invariance of the orbital magnetic moment and energy conservation following Liouville's theorem for Hamiltonian systems.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.
-
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and Directional Detection of MeV Dark Matter
Authors:
E. Baracchini,
M. G. Betti,
M. Biasotti,
A. Bosca,
F. Calle,
J. Carabe-Lopez,
G. Cavoto,
C. Chang,
A. G. Cocco,
A. P. Colijn,
J. Conrad,
N. D'Ambrosio,
P. F. de Salas,
M. Faverzani,
A. Ferella,
E. Ferri,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
J. Gudmundsson,
Y. Hochberg,
Y. Kahn
, et al. (26 additional authors not shown)
Abstract:
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphen…
▽ More
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphene technology for a tritium target and the demonstration of TES microcalorimetry with an energy resolution of better than 0.05 eV for low energy electrons. These technologies will be evaluated using the PTOLEMY prototype, proposed for underground installation, using precision HV controls to step down the kinematic energy of endpoint electrons to match the calorimeter dynamic range and rate capabilities. The second phase will produce a novel implementation of the EM filter that is scalable to the full target size and which demonstrates intrinsic triggering capability for selecting endpoint electrons. Concurrent with the CNB program, we plan to exploit and develop the unique properties of graphene to implement an intermediate program for direct directional detection of MeV dark matter [3,4]. This program will evaluate the radio-purity and scalability of the graphene fabrication process with the goal of using recently identified ultra-high radio-purity CO2 sources. The direct detection of the CNB is a snapshot of early universe dynamics recorded by the thermal relic neutrino yield taken at a time that predates the epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to have a central role in the evolution of the Universe and a direct measurement with PTOLEMY will unequivocally establish the extent to which these predictions match present-day neutrino densities.
△ Less
Submitted 6 August, 2018;
originally announced August 2018.