Validation of the VUV-reflective coating for next-generation liquid xenon detectors
Authors:
D. Bajpai,
A. Best,
I. Ostrovskiy,
D. Poitras,
W. Wang
Abstract:
Coating detector materials with films highly reflective in the ultraviolet region improves sensitivity of the rare-event detectors that use liquid xenon. In this work, we investigate the MgF$_2$-Al-MgF$_2$ coating designed to achieve high reflectance at 175 nm, the mean wavelength of liquid xenon (LXe) scintillation. The coating was applied to an unpolished, passivated copper substrate mimicking a…
▽ More
Coating detector materials with films highly reflective in the ultraviolet region improves sensitivity of the rare-event detectors that use liquid xenon. In this work, we investigate the MgF$_2$-Al-MgF$_2$ coating designed to achieve high reflectance at 175 nm, the mean wavelength of liquid xenon (LXe) scintillation. The coating was applied to an unpolished, passivated copper substrate mimicking a realistic detector component of the proposed nEXO experiment, as well as to two unpassivated substrates with "high" and "average" levels of polishing. After confirming the composition and morphology of the thin-film coating using TEM and EDS, the samples underwent reflectance measurements in LXe and gaseous nitrogen (GN2). Measurements in LXe exposed the coated samples to -100 $°$C for several hours. No peeling of the coatings was observed after several thermal cycles. Polishing is found to strongly correlate with the measured specular reflectance ($R_{\mathrm{spec}}$). In particular, 5.8(5)% specular spike reflectance in LXe was measured for the realistic sample at 20$°$ of incidence, while the values for similar angles of incidence on the high and average polish samples are 62.3(1.3)% and 27.4(7)%, respectively. At large angles (66°--75$°$), the $R_{\mathrm{spec}}$ in LXe for the three samples increases to 23(5)%, 80(8)%, and 84(18)%, respectively. The $R_{\mathrm{spec}}$ at around 45$°$ was measured in both GN2 and LXe for average polish sample and shows a reasonable agreement. Importantly, the total reflectance of the samples is comparable and estimated to be 92(8)%, 85(8)%, and 83(8)% in GN2 for the realistic, average, and high polish samples, respectively. This is considered satisfactory for the next-generation LXe experiments that could benefit from using reflective films, such as nEXO and DARWIN, thus validating the design of the coating.
△ Less
Submitted 14 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Comparing intervention measures in a model of a disease outbreak on a university campus
Authors:
Alex Best,
Prerna Singh
Abstract:
A number of theoretical models have been developed in recent years modelling epidemic spread in educational settings such as universities to help inform re-opening strategies during the Covid-19 pandemic. However, these studies have had differing conclusions as to the most effective non-pharmaceutical interventions. They also largely assumed permanent acquired immunity, meaning we have less unders…
▽ More
A number of theoretical models have been developed in recent years modelling epidemic spread in educational settings such as universities to help inform re-opening strategies during the Covid-19 pandemic. However, these studies have had differing conclusions as to the most effective non-pharmaceutical interventions. They also largely assumed permanent acquired immunity, meaning we have less understanding of how disease dynamics will play out when immunity wanes. Here we complement these studies by develo** and analysing a stochastic simulation model of disease spread on a university campus where we allow immunity to wane, expoloring the effectiveness of different interventions. We find that the two most effective interventions to limit the severity of a disease outbreak are reducing extra-household mixing and surveillance testing backed-up by a moderate isolation period. We find that contact tracing only has a limited effect, while reducing class sizes only has much effect if extra-household mixing is already low. We identify a range of measures that can not only limit an outbreak but prevent it entirely, and also comment on the variation in measures of severity that emerge from our stochastic simulations. We hope that our model may help in designing effective strategies for universities in future disease outbreaks.
△ Less
Submitted 16 June, 2023;
originally announced June 2023.
-
A Comparison of Proton Stop** Power Measured with Proton CT and x-ray CT in Fresh Post-Mortem Porcine Structures
Authors:
Don F. DeJongh,
Ethan A. DeJongh,
Victor Rykalin,
Greg DeFillippo,
Mark Pankuch,
Andrew W. Best,
George Coutrakon,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Christina Sarosiek,
Reinhard W. Schulte,
John R. Winans,
Alec M. Block,
Courtney L. Hentz,
James S. Welsh
Abstract:
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stop** power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stop** power. We aim to demonstr…
▽ More
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stop** power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stop** power. We aim to demonstrate proton CT imaging with complex porcine samples, to analyze in detail three-dimensional regions of interest, and to compare proton stop** powers directly measured by proton CT to those determined from x-ray CT scans.
Methods: We have used a prototype proton imaging system with single proton tracking to acquire proton radiography and proton CT images of a sample of porcine pectoral girdle and ribs, and a pig's head. We also acquired close in time x-ray CT scans of the same samples, and compared proton stop** power measurements from the two modalities. In the case of the pig's head, we obtained x-ray CT scans from two different scanners, and compared results from high-dose and low-dose settings.
Results: Comparing our reconstructed proton CT images with images derived from x-ray CT scans, we find agreement within 1% to 2% for soft tissues, and discrepancies of up to 6% for compact bone. We also observed large discrepancies, up to 40%, for cavitated regions with mixed content of air, soft tissue, and bone, such as sinus cavities or tympanic bullae.
Conclusions: Our images and findings from a clinically realistic proton CT scanner demonstrate the potential for proton CT to be used for low-dose treatment planning with reduced margins.
△ Less
Submitted 29 October, 2021; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Setup commissioning for an improved measurement of the D(p,gamma)3He cross section at Big Bang Nucleosynthesis energies
Authors:
V. Mossa,
K. Stöckel,
F. Cavanna,
F. Ferraro,
M. Aliotta,
F. Barile,
D. Bemmerer,
A. Best,
A. Boeltzig,
C. Broggini,
C. G. Bruno,
A. Caciolli,
L. Csedreki,
T. Chillery,
G. F. Ciani,
P. Corvisiero,
T. Davinson,
R. Depalo,
A. Di Leva,
Z. Elekes,
E. M. Fiore,
A. Formicola,
Zs. Fülöp,
G. Gervino,
A. Guglielmetti
, et al. (22 additional authors not shown)
Abstract:
Among the reactions involved in the production and destruction of deuterium during Big Bang Nucleosynthesis, the deuterium-burning D(p,gamma)3He reaction has the largest uncertainty and limits the precision of theoretical estimates of primordial deuterium abundance. Here we report the results of a careful commissioning of the experimental setup used to measure the cross-section of the D(p,gamma)3H…
▽ More
Among the reactions involved in the production and destruction of deuterium during Big Bang Nucleosynthesis, the deuterium-burning D(p,gamma)3He reaction has the largest uncertainty and limits the precision of theoretical estimates of primordial deuterium abundance. Here we report the results of a careful commissioning of the experimental setup used to measure the cross-section of the D(p,gamma)3He reaction at the Laboratory for Underground Nuclear Astrophysics of the Gran Sasso Laboratory (Italy). The commissioning was aimed at minimising all sources of systematic uncertainty in the measured cross sections. The overall systematic error achieved (< 3 %) will enable improved predictions of BBN deuterium abundance.
△ Less
Submitted 29 April, 2020;
originally announced May 2020.
-
A new approach to monitor 13C-targets degradation in situ for 13C(alpha,n)16O cross-section measurements at LUNA
Authors:
G. F. Ciani,
L. Csedreki,
J. Balibrea-Correa,
A. Best,
M. Aliotta,
F. Barile,
D. Bemmerer,
A. Boeltzig,
C. Broggini,
C. G. Bruno,
A. Caciolli,
F. Cavanna,
T. Chillery,
P. Colombetti,
P. Corvisiero,
T. Davinson,
R. Depalo,
A. Di Leva,
L. Di Paolo,
Z. Elekes,
F. Ferraro,
E. M. Fiore,
A. Formicola,
Zs. Fulop,
G. Gervino
, et al. (24 additional authors not shown)
Abstract:
Direct measurements of reaction cross-sections at astrophysical energies often require the use of solid targets able to withstand high ion beam currents for extended periods of time. Thus, monitoring target thickness, isotopic composition, and target stoichiometry during data taking is critical to account for possible target modifications and to reduce uncertainties in the final cross-section resu…
▽ More
Direct measurements of reaction cross-sections at astrophysical energies often require the use of solid targets able to withstand high ion beam currents for extended periods of time. Thus, monitoring target thickness, isotopic composition, and target stoichiometry during data taking is critical to account for possible target modifications and to reduce uncertainties in the final cross-section results. A common technique used for these purposes is the Nuclear Resonant Reaction Analysis (NRRA), which however requires that a narrow resonance be available inside the dynamic range of the accelerator used. In cases when this is not possible, as for example the 13C(alpha,n)16O reaction recently studied at low energies at the Laboratory for Underground Nuclear Astrophysics (LUNA) in Italy, alternative approaches must be found. Here, we present a new application of the shape analysis of primary gamma rays emitted by the 13C(p,g)14N radiative capture reaction. This approach was used to monitor 13C target degradation {\em in situ} during the 13C(alpha,n)16O data taking campaign. The results obtained are in agreement with evaluations subsequently performed at Atomki (Hungary) using the NRRA method. A preliminary application for the extraction of the 13C(alpha,n)16O reaction cross-section at one beam energy is also reported.
△ Less
Submitted 3 March, 2020; v1 submitted 23 January, 2020;
originally announced January 2020.
-
Underground nuclear astrophysics: why and how
Authors:
A. Best,
A. Caciolli,
Zs. Fülöp,
Gy. Gyürky,
M. Laubenstein,
E. Napolitani,
V. Rigato,
V. Roca,
T. Szücs
Abstract:
The goal of nuclear astrophysics is to measure cross sections of nuclear physics reactions of interest in astrophysics. At stars temperatures, these cross sections are very low due to the suppression of the Coulomb barrier. Cosmic ray induced background can seriously limit the determination of reaction cross sections at energies relevant to astrophysical processes and experimental setups should be…
▽ More
The goal of nuclear astrophysics is to measure cross sections of nuclear physics reactions of interest in astrophysics. At stars temperatures, these cross sections are very low due to the suppression of the Coulomb barrier. Cosmic ray induced background can seriously limit the determination of reaction cross sections at energies relevant to astrophysical processes and experimental setups should be arranged in order to improve the signal-to-noise ratio. Placing experiments in underground sites, however, reduces this background opening the way towards ultra low cross section determination. LUNA (Laboratory for Underground Nuclear Astrophysics) was pioneer in this sense. Two accelerators were mounted at the INFN National Laboratories of Gran Sasso (LNGS) allowing to study nuclear reactions close to stellar energies. A summary of the relevant technology used, including accelerators, target production and characterisation, and background treatment is given.
△ Less
Submitted 2 January, 2016;
originally announced January 2016.
-
Low energy neutron background in deep underground laboratories
Authors:
Andreas Best,
Joachim Gorres,
Matthias Junker,
Karl-Ludwig Kratz,
Matthias Laubenstein,
Alexander Long,
Stefano Nisi,
Karl Smith,
Michael Wiescher
Abstract:
The natural neutron background influences the maximum achievable sensitivity in most deep underground nuclear, astroparticle and double-beta decay physics experiments. Reliable neutron flux numbers are an important ingredient in the design of the shielding of new large-scale experiments as well as in the analysis of experimental data.
Using a portable setup of He-3 counters we measured the therm…
▽ More
The natural neutron background influences the maximum achievable sensitivity in most deep underground nuclear, astroparticle and double-beta decay physics experiments. Reliable neutron flux numbers are an important ingredient in the design of the shielding of new large-scale experiments as well as in the analysis of experimental data.
Using a portable setup of He-3 counters we measured the thermal neutron flux at the Kimballton Underground Research Facility, the Soudan Underground Laboratory, on the 4100 ft and the 4850 ft levels of the Sanford Underground Research Facility, at the Waste Isolation Pilot Plant and at the Gran Sasso National Laboratory. Absolute neutron fluxes at these laboratories are presented.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.