IceCube-Gen2 - The Next Generation Neutrino Observatory at the South Pole: Contributions to ICRC 2015
Authors:
The IceCube-Gen2 Collaboration,
:,
M. G. Aartsen,
K. Abraham,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
D. Altmann,
T. Anderson,
I. Ansseau,
G. Anton,
M. Archinger,
C. Arguelles,
T. C. Arlen,
J. Auffenberg,
S. Axani,
X. Bai,
I. Bartos,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker Tjus
, et al. (316 additional authors not shown)
Abstract:
Papers submitted to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague) by the IceCube-Gen2 Collaboration.
Papers submitted to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague) by the IceCube-Gen2 Collaboration.
△ Less
Submitted 9 November, 2015; v1 submitted 18 October, 2015;
originally announced October 2015.
-
Determining neutrino oscillation parameters from atmospheric muon neutrino disappearance with three years of IceCube DeepCore data
Authors:
IceCube Collaboration,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
D. Altmann,
T. Anderson,
C. Arguelles,
T. C. Arlen,
J. Auffenberg,
X. Bai,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker Tjus,
K. -H. Becker,
S. BenZvi,
P. Berghaus,
D. Berley,
E. Bernardini,
A. Bernhard,
D. Z. Besson
, et al. (279 additional authors not shown)
Abstract:
We present a measurement of neutrino oscillations via atmospheric muon neutrino disappearance with three years of data of the completed IceCube neutrino detector. DeepCore, a region of denser instrumentation, enables the detection and reconstruction of atmospheric muon neutrinos between 10 GeV and 100 GeV, where a strong disappearance signal is expected. The detector volume surrounding DeepCore is…
▽ More
We present a measurement of neutrino oscillations via atmospheric muon neutrino disappearance with three years of data of the completed IceCube neutrino detector. DeepCore, a region of denser instrumentation, enables the detection and reconstruction of atmospheric muon neutrinos between 10 GeV and 100 GeV, where a strong disappearance signal is expected. The detector volume surrounding DeepCore is used as a veto region to suppress the atmospheric muon background. Neutrino events are selected where the detected Cherenkov photons of the secondary particles minimally scatter, and the neutrino energy and arrival direction are reconstructed. Both variables are used to obtain the neutrino oscillation parameters from the data, with the best fit given by $Δm^2_{32}=2.72^{+0.19}_{-0.20}\times 10^{-3}\,\mathrm{eV}^2$ and $\sin^2θ_{23} = 0.53^{+0.09}_{-0.12}$ (normal mass hierarchy assumed). The results are compatible and comparable in precision to those of dedicated oscillation experiments.
△ Less
Submitted 13 April, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
Energy Reconstruction Methods in the IceCube Neutrino Telescope
Authors:
IceCube Collaboration,
M. G. Aartsen,
R. Abbasi,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
D. Altmann,
C. Arguelles,
J. Auffenberg,
X. Bai,
M. Baker,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker Tjus,
K. -H. Becker,
S. BenZvi,
P. Berghaus,
D. Berley,
E. Bernardini,
A. Bernhard,
D. Z. Besson,
G. Binder
, et al. (263 additional authors not shown)
Abstract:
Accurate measurement of neutrino energies is essential to many of the scientific goals of large-volume neutrino telescopes. The fundamental observable in such detectors is the Cherenkov light produced by the transit through a medium of charged particles created in neutrino interactions. The amount of light emitted is proportional to the deposited energy, which is approximately equal to the neutrin…
▽ More
Accurate measurement of neutrino energies is essential to many of the scientific goals of large-volume neutrino telescopes. The fundamental observable in such detectors is the Cherenkov light produced by the transit through a medium of charged particles created in neutrino interactions. The amount of light emitted is proportional to the deposited energy, which is approximately equal to the neutrino energy for $ν_e$ and $ν_μ$ charged-current interactions and can be used to set a lower bound on neutrino energies and to measure neutrino spectra statistically in other channels. Here we describe methods and performance of reconstructing charged-particle energies and topologies from the observed Cherenkov light yield, including techniques to measure the energies of uncontained muon tracks, achieving average uncertainties in electromagnetic-equivalent deposited energy of $\sim 15\%$ above 10 TeV.
△ Less
Submitted 10 February, 2014; v1 submitted 19 November, 2013;
originally announced November 2013.
-
Measurement of South Pole ice transparency with the IceCube LED calibration system
Authors:
IceCube Collaboration,
M. G. Aartsen,
R. Abbasi,
Y. Abdou,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
D. Altmann,
J. Auffenberg,
X. Bai,
M. Baker,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
S. Bechet,
J. Becker Tjus,
K. -H. Becker,
M. Bell,
M. L. Benabderrahmane,
S. BenZvi,
J. Berdermann,
P. Berghaus,
D. Berley
, et al. (250 additional authors not shown)
Abstract:
The IceCube Neutrino Observatory, approximately 1 km^3 in size, is now complete with 86 strings deployed in the Antarctic ice. IceCube detects the Cherenkov radiation emitted by charged particles passing through or created in the ice. To realize the full potential of the detector, the properties of light propagation in the ice in and around the detector must be well understood. This report present…
▽ More
The IceCube Neutrino Observatory, approximately 1 km^3 in size, is now complete with 86 strings deployed in the Antarctic ice. IceCube detects the Cherenkov radiation emitted by charged particles passing through or created in the ice. To realize the full potential of the detector, the properties of light propagation in the ice in and around the detector must be well understood. This report presents a new method of fitting the model of light propagation in the ice to a data set of in-situ light source events collected with IceCube. The resulting set of derived parameters, namely the measured values of scattering and absorption coefficients vs. depth, is presented and a comparison of IceCube data with simulations based on the new model is shown.
△ Less
Submitted 22 January, 2013;
originally announced January 2013.
-
An improved method for measuring muon energy using the truncated mean of dE/dx
Authors:
IceCube collaboration,
R. Abbasi,
Y. Abdou,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
D. Altmann,
K. Andeen,
J. Auffenberg,
X. Bai,
M. Baker,
S. W. Barwick,
V. Baum,
R. Bay,
K. Beattie,
J. J. Beatty,
S. Bechet,
J. Becker Tjus,
K. -H. Becker,
M. Bell,
M. L. Benabderrahmane,
S. BenZvi,
J. Berdermann,
P. Berghaus
, et al. (255 additional authors not shown)
Abstract:
The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV)…
▽ More
The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.
△ Less
Submitted 9 November, 2012; v1 submitted 16 August, 2012;
originally announced August 2012.
-
Use of event-level neutrino telescope data in global fits for theories of new physics
Authors:
P. Scott,
C. Savage,
J. Edsjö,
the IceCube Collaboration,
:,
R. Abbasi,
Y. Abdou,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
D. Altmann,
K. Andeen,
J. Auffenberg,
X. Bai,
M. Baker,
S. W. Barwick,
V. Baum,
R. Bay,
K. Beattie,
J. J. Beatty,
S. Bechet,
J. Becker Tjus,
K. -H. Becker,
M. Bell
, et al. (253 additional authors not shown)
Abstract:
We present a fast likelihood method for including event-level neutrino telescope data in parameter explorations of theories for new physics, and announce its public release as part of DarkSUSY 5.0.6. Our construction includes both angular and spectral information about neutrino events, as well as their total number. We also present a corresponding measure for simple model exclusion, which can be u…
▽ More
We present a fast likelihood method for including event-level neutrino telescope data in parameter explorations of theories for new physics, and announce its public release as part of DarkSUSY 5.0.6. Our construction includes both angular and spectral information about neutrino events, as well as their total number. We also present a corresponding measure for simple model exclusion, which can be used for single models without reference to the rest of a parameter space. We perform a number of supersymmetric parameter scans with IceCube data to illustrate the utility of the method: example global fits and a signal recovery in the constrained minimal supersymmetric standard model (CMSSM), and a model exclusion exercise in a 7-parameter phenomenological version of the MSSM. The final IceCube detector configuration will probe almost the entire focus-point region of the CMSSM, as well as a number of MSSM-7 models that will not otherwise be accessible to e.g. direct detection. Our method accurately recovers the mock signal, and provides tight constraints on model parameters and derived quantities. We show that the inclusion of spectral information significantly improves the accuracy of the recovery, providing motivation for its use in future IceCube analyses.
△ Less
Submitted 1 October, 2012; v1 submitted 3 July, 2012;
originally announced July 2012.