Skip to main content

Showing 1–18 of 18 results for author: Behnke, E

Searching in archive physics. Search in all archives.
.
  1. arXiv:2405.18403  [pdf, other

    physics.ins-det

    Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber

    Authors: H. Hawley-Herrera, E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. Corbett, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, X. Liu, N. Moss, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (6 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with re… ▽ More

    Submitted 28 May, 2024; originally announced May 2024.

    Comments: 25 pages, 19 figures

    Report number: FERMILAB-PUB-24-0280-LDRD-PPD

  2. arXiv:2207.12400  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection

    Authors: E. Alfonso-Pita, M. Baker, E. Behnke, A. Brandon, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, C. Cripe, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, K. Foy, P. Giampa, J. Gresl, J. Hall, O. Harris, H. Hawley-Herrera, C. M. Jackson, M. Khatri, Y. Ko, N. Lamb , et al. (20 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev… ▽ More

    Submitted 29 September, 2022; v1 submitted 21 July, 2022; originally announced July 2022.

    Comments: 35 pages, 12 figures, contributed white paper to Snowmass 2021 (final version for Snowmass proceedings)

    Report number: FERMILAB-CONF-22-535-LDRD-PPD

  3. arXiv:2205.05771  [pdf, other

    physics.ins-det astro-ph.IM

    Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

    Authors: B. Ali, I. J. Arnquist, D. Baxter, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. I. Collar, P. S. Cooper, C. Cripe, M. Crisler, C. E. Dahl, M. Das, D. Durnford, S. Fallows, J. Farine, R. Filgas, A. García-Viltres, F. Girard, G. Giroux, O. Harris, E. W. Hoppe, C. M. Jackson, M. **, C. B. Krauss , et al. (32 additional authors not shown)

    Abstract: The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct… ▽ More

    Submitted 7 November, 2022; v1 submitted 11 May, 2022; originally announced May 2022.

    Comments: 17 pages, 22 figures, 5 tables

  4. arXiv:2101.08785  [pdf, other

    hep-ex hep-ph nucl-ex physics.ins-det

    Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments

    Authors: L. J. Flores, Eduardo Peinado, E. Alfonso-Pita, K. Allen, M. Baker, E. Behnke, M. Bressler, K. Clark, R. Coppejans, C. Cripe, M. Crisler, C. E. Dahl, A. de St. Croix, D. Durnford, P. Giampa, O. Harris, P. Hatch, H. Hawley, C. M. Jackson, Y. Ko, C. Krauss, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott , et al. (9 additional authors not shown)

    Abstract: The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig… ▽ More

    Submitted 26 May, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Comments: 9 pages, 5 figures. v2: figures added, minor changes. Matches published version

    Journal ref: Phys. Rev. D 103, 091301 (2021)

  5. arXiv:1905.12522  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex hep-ph

    Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, S. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, R. Filgas , et al. (54 additional authors not shown)

    Abstract: The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by… ▽ More

    Submitted 25 November, 2020; v1 submitted 29 May, 2019; originally announced May 2019.

    Comments: 18 pages, 12 figures

    Journal ref: Phys. Rev. D 100, 082006 (2019)

  6. arXiv:1902.04031  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas , et al. (47 additional authors not shown)

    Abstract: Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

    Comments: 9 pages, 8 figures

    Journal ref: Phys. Rev. D 100, 022001 (2019)

  7. arXiv:1811.11308  [pdf, other

    physics.comp-ph physics.ins-det

    Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

    Authors: B. Matusch, C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis , et al. (48 additional authors not shown)

    Abstract: The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing… ▽ More

    Submitted 27 November, 2018; originally announced November 2018.

    Comments: 27 pages, 10 figures

  8. arXiv:1702.07666  [pdf, ps, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, P. Campion, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, G. Crowder, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas, F. Girard , et al. (37 additional authors not shown)

    Abstract: New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th… ▽ More

    Submitted 2 August, 2017; v1 submitted 24 February, 2017; originally announced February 2017.

    Comments: 6 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 118, 251301 (2017)

  9. arXiv:1611.01499  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Final Results of the PICASSO Dark Matter Search Experiment

    Authors: E. Behnke, M. Besnier, P. Bhattacharjee, X. Dai, M. Das, A. Davour, F. Debris, N. Dhungana, J. Farine, M. Fines-Neuschild, S. Gagnebin, G. Giroux, E. Grace, C. M. Jackson, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, L. Lessard, I. Levine, D. Marlisov, J. -P. Martin, P. Mitra, A. J. Noble , et al. (9 additional authors not shown)

    Abstract: The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to… ▽ More

    Submitted 23 March, 2017; v1 submitted 4 November, 2016; originally announced November 2016.

    Comments: 24 pages, 7 figures

    Journal ref: Astropart. Phys. 90, 85-92 (2017)

  10. arXiv:1601.03729  [pdf, other

    astro-ph.CO physics.ins-det

    Improved dark matter search results from PICO-2L Run 2

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, M. Das, F. Debris, S. Fallows, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (33 additional authors not shown)

    Abstract: New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu… ▽ More

    Submitted 25 March, 2016; v1 submitted 14 January, 2016; originally announced January 2016.

    Journal ref: Phys. Rev. D 93, 061101 (2016)

  11. arXiv:1510.07754  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, F. Girard, G. Giroux, A. Grandison , et al. (34 additional authors not shown)

    Abstract: New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays… ▽ More

    Submitted 3 March, 2016; v1 submitted 26 October, 2015; originally announced October 2015.

    Comments: v3 to reflect published version

    Journal ref: Phys. Rev. D 93, 052014 (2016)

  12. arXiv:1503.00008  [pdf, other

    astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (32 additional authors not shown)

    Abstract: New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o… ▽ More

    Submitted 29 June, 2015; v1 submitted 27 February, 2015; originally announced March 2015.

    Comments: 6 pages, 6 figures, v2 to match published version

    Journal ref: Phys. Rev. Lett. 114, 231302 (2015)

  13. arXiv:1304.6001  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

    Authors: COUPP Collaboration, E. Behnke, T. Benjamin, S. J. Brice, D. Broemmelsiek, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, J. Hall, C. Harnish, I. Levine, W. H. Lippincott, T. Moan, T. Nania, R. Neilson, E. Ramberg, A. E. Robinson, A. Sonnenschein, E. Vázquez-Jáuregui, R. A. Rivera, L. Uplegger

    Abstract: We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel… ▽ More

    Submitted 31 January, 2014; v1 submitted 22 April, 2013; originally announced April 2013.

    Comments: 5 pages, 3 figures

    Report number: FERMILAB-PUB-10-318-A-CD-E

    Journal ref: Phys. Rev. D 88, 021102 (2013)

  14. arXiv:1011.4553  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    New Insights into Particle Detection with Superheated Liquids

    Authors: S. Archambault, F. Aubin, M. Auger, M. Beleshi, E. Behnke, J. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, F. Debris. J. Farine, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, H. Hinnefeld, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, C. Leroy, C. Lévy, L. Lessard, I. Levine , et al. (12 additional authors not shown)

    Abstract: We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy threshold… ▽ More

    Submitted 20 November, 2010; originally announced November 2010.

    Journal ref: New J.Phys.13:043006,2011

  15. arXiv:0807.1536  [pdf, ps, other

    physics.ins-det hep-ex

    Discrimination of nuclear recoils from alpha particles with superheated liquids

    Authors: F. Aubin, M. Auger, E. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, C. Levy, J. -P. Martin, T. Morlat, A. J. Noble, P. Nadeau, M. -C. Piro, S. Pospisil, T. Shepherd, J. Sodomka, N. Starinski , et al. (4 additional authors not shown)

    Abstract: The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubble… ▽ More

    Submitted 23 September, 2008; v1 submitted 10 July, 2008; originally announced July 2008.

    Comments: 7 pages, 4 figures. accepted for publication in New Journal of Physics

    Journal ref: NewJ.Phys.10:103017,2008

  16. arXiv:0804.2886  [pdf, ps, other

    astro-ph hep-ex physics.ins-det

    Improved Spin-Dependent WIMP Limits from a Bubble Chamber

    Authors: E. Behnke, J. I. Collar, P. S. Cooper, K. Crum, M. Crisler, M. Hu, I. Levine, D. Nakazawa, H. Nguyen, B. Odom, E. Ramberg, J. Rasmussen, N. Riley, A. Sonnenschein, M. Szydagis, R. Tschirhart

    Abstract: Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly… ▽ More

    Submitted 17 April, 2008; originally announced April 2008.

    Comments: This is the author's version of the work. It is posted here by permission of the AAAS for personal use, not for redistribution. The definitive version was published in Science 319, 15 February 2008, doi:10.1126/science.1149999

    Journal ref: Science 319:933-936,2008

  17. Response of Superheated Droplet Detectors of the PICASSO Dark Matter Search Experiment

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M. -H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, J. -P. Martin, C. Muthusi, A. J. Noble, R. Noulty, U. Wichoski, V. Zacek

    Abstract: We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of superheated liquid Freon droplets dispersed and trapped in a polymerized gel. Phase transitions can be induced by nuclear recoils following particle interactions and,… ▽ More

    Submitted 15 August, 2005; originally announced August 2005.

    Comments: 70 pages, 33 low resolution figures; higher resolution figures available at http://picassoweb.lps.umontreal.ca/ . Submitted to NIM A

    Journal ref: Nucl.Instrum.Meth. A555 (2005) 184-204

  18. arXiv:physics/0408126  [pdf

    physics.ins-det hep-ex

    Simulation of Special Bubble Detectors for PICASSO

    Authors: The PICASSO Collaboration, G. Azuelos, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M-H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. Krauss, C. Leroy, L. Lessard, I. Levine, J. P. Martin, A. J. Noble, R. Noulty, S. N. Shore, U. Wichoski, V . Zacek

    Abstract: The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection technique is based on the phase transition of superheated droplets at about room temperature and ambient pressure. The phase transition is induced by nuclear… ▽ More

    Submitted 30 August, 2004; originally announced August 2004.

    Comments: 13 pages, 4 figures. To appear in the Proceedings of the 14th International Conference on Solid State Dosimetry, June 27 - July 2 2004, Yale University, New Haven, CT, USA

    Journal ref: Radiat.Prot.Dosim.120:499-502,2006