-
Increasing the rate capability for the cryogenic stop** cell of the FRS Ion Catcher
Authors:
J. W. Zhao,
D. Amanbayev,
T. Dickel,
I. Miskun,
W. R. Plass,
N. Tortorelli,
S. Ayet San Andres,
Soenke Beck,
J. Bergmann,
Z. Brencic,
P. Constantin,
H. Geissel,
F. Greiner,
L. Groef,
C. Hornung,
N. Kuzminzuk,
G. Kripko-Koncz,
I. Mardor,
I. Pohjalainen,
C. Scheidenberger,
P. G. Thirolf,
S. Bagchi,
E. Haettner,
E. Kazantseva,
D. Kostyleva
, et al. (23 additional authors not shown)
Abstract:
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stop** cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Sup…
▽ More
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stop** cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Super-FRS, where exotic nuclei will be produced at unprecedented rates making it possible to go towards the extremes of the nuclear chart. Therefore, it is essential to efficiently extract thermalized exotic nuclei from the CSC under high beam rate conditions, in order to use the rare exotic nuclei which come as cocktail beams. The extraction efficiency dependence on the intensity of the im**ing beam into the CSC was studied with a primary beam of 238U and its fragments. Tests were done with two different versions of the DC electrode structure inside the cryogenic chamber, the standard 1 m long and a short 0.5 m long DC electrode. In contrast to the rate capability of 10^4 ions/s with the long DC electrode, results show no extraction efficiency loss up to the rate of 2x10^5 ions/s with the new short DC electrode. This order of magnitude increase of the rate capability paves the way for new experiments at the FRS-IC, including exotic nuclei studies with in-cell multi-nucleon transfer reactions. The results further validate the design concept of the CSC for the Super-FRS, which was developed to effectively manage beams of even higher intensities.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Recent Upgrades of the Gas Handling System for the Cryogenic Stop** Cell of the FRS Ion Catcher
Authors:
A. Mollaebrahimi,
D. Amanbayev,
S. Ayet San Andrés,
S. Beck,
J. Bergmann,
T. Dickel,
H. Geissel,
C. Hornung,
N. Kalantar-Nayestanaki,
G. Kripko-Koncz,
I. Miskun,
D. Nichita,
W. R. Plaß,
I. Pohjalainen,
C. Scheidenberger,
G. Stanic,
A. State,
J. Zhao
Abstract:
In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stop** cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecu…
▽ More
In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stop** cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stop** cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.
△ Less
Submitted 25 July, 2023;
originally announced July 2023.
-
Mean range bunching of exotic nuclei produced by in-flight fragmentation and fission -- Stopped-beam experiments with increased efficiency
Authors:
Timo Dickel,
Christine Hornung,
Daler Amanbayev,
Samuel Ayet San Andres,
Soenke Beck,
Julian Bergmann,
Hans Geissel,
Juergen Gerl,
Magdalena Gorska,
Lizzy Groef,
Emma Haettner,
Jan-Paul Hucka,
Daria A. Kostyleva,
Gabriella Kripko-Koncz,
Ali Mollaebrahimi,
Ivan Mukha,
Stephane Pietri,
Wolfgang R. Plaß,
Zsolt Podolyak,
Sivaji Purushothaman,
Moritz Pascal Reiter,
Heidi Roesch,
Christoph Scheidenberger,
Yoshiki K. Tanaka,
Helmut Weick
, et al. (2 additional authors not shown)
Abstract:
The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-…
▽ More
The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-filled stop** cell or an implantation detector. Stop** and studying a cocktail beam overcomes the present limitations of stopped-beam experiments. The conceptual idea of mean range bunching is described and illustrated using simulations. In a single setting of the FRS, 37 different nuclides were stopped in the cryogenic stop** cell and were measured in a single setting broadband mass measurement with the multiple-reflection time-of-flight mass spectrometer of the FRS Ion Catcher.
△ Less
Submitted 30 May, 2023;
originally announced June 2023.
-
Unconstrained quantitative magnetization transfer imaging: disentangling T1 of the free and semi-solid spin pools
Authors:
Jakob Assländer,
Andrew Mao,
Elisa Marchetto,
Erin S Beck,
Francesco La Rosa,
Robert W Charlson,
Timothy M Shepherd,
Sebastian Flassbeck
Abstract:
Since the inception of magnetization transfer (MT) imaging, it has been widely assumed that Henkelman's two spin pools have similar longitudinal relaxation times, which motivated many researchers to constrain them to each other. However, several recent publications reported a $T_1^s$ of the semi-solid spin pool that is much shorter than $T_1^f$ of the free pool. While these studies tailored experi…
▽ More
Since the inception of magnetization transfer (MT) imaging, it has been widely assumed that Henkelman's two spin pools have similar longitudinal relaxation times, which motivated many researchers to constrain them to each other. However, several recent publications reported a $T_1^s$ of the semi-solid spin pool that is much shorter than $T_1^f$ of the free pool. While these studies tailored experiments for robust proofs-of-concept, we here aim to quantify the disentangled relaxation processes on a voxel-by-voxel basis in a clinical imaging setting, i.e., with an effective resolution of 1.24mm isotropic and full brain coverage in 12min. To this end, we optimized a hybrid-state pulse sequence for map** the parameters of an unconstrained MT model. We scanned four people with relapsing-remitting multiple sclerosis (MS) and four healthy controls with this pulse sequence and estimated $T_1^f \approx 1.84$s and $T_1^s \approx 0.34$s in healthy white matter. Our results confirm the reports that $T_1^s \ll T_1^f$ and we argue that this finding identifies MT as an inherent driver of longitudinal relaxation in brain tissue. Moreover, we estimated a fractional size of the semi-solid spin pool of $m_0^s \approx 0.212$, which is larger than previously assumed. An analysis of $T_1^f$ in normal-appearing white matter revealed statistically significant differences between individuals with MS and controls.
△ Less
Submitted 1 April, 2024; v1 submitted 19 January, 2023;
originally announced January 2023.
-
Training biases in machine learning for the analytic continuation of quantum many-body Green's functions
Authors:
Rong Zhang,
Maximilian E. Merkel,
Sophie Beck,
Claude Ederer
Abstract:
We address the problem of analytic continuation of imaginary-frequency Green's functions, which is crucial in many-body physics, using machine learning based on a multi-level residual neural network. We specifically address potential biases that can be introduced due to the use of artificially created spectral functions that are employed to train the neural network. We also implement an uncertaint…
▽ More
We address the problem of analytic continuation of imaginary-frequency Green's functions, which is crucial in many-body physics, using machine learning based on a multi-level residual neural network. We specifically address potential biases that can be introduced due to the use of artificially created spectral functions that are employed to train the neural network. We also implement an uncertainty estimation of the predicted spectral function, based on Monte Carlo dropout, which allows to identify frequency regions where the prediction might not be accurate, and we study the effect of noise, in particular also for situations where the noise level during training is different from that in the actual data. Our analysis demonstrates that this method can indeed achieve a high quality of prediction, comparable or better than the widely used maximum entropy method, but that further improvement is currently limited by the lack of true data that can be used for training. We also benchmark our approach by applying it to the case of SrVO$_3$, where an accurate spectral function has been obtained from dynamical mean-field theory using a solver that works directly on the real frequency axis.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
Sensing Strain-induced Symmetry Breaking by Reflectance Anisotropy Spectroscopy
Authors:
M. Volpi,
S. Beck,
A. Hampel,
H. Galinski,
A. Sologubenko,
R. Spolenak
Abstract:
Intentional breaking of the lattice symmetry in solids is a key concept to alter the properties of materials by modifying their electronic band structure. However, the correlation of strain-induced effects and breaking of the lattice symmetry is often indirect, resorting to vibrational spectroscopic techniques such as Raman scattering. Here, we demonstrate that reflectance anisotropy spectroscopy…
▽ More
Intentional breaking of the lattice symmetry in solids is a key concept to alter the properties of materials by modifying their electronic band structure. However, the correlation of strain-induced effects and breaking of the lattice symmetry is often indirect, resorting to vibrational spectroscopic techniques such as Raman scattering. Here, we demonstrate that reflectance anisotropy spectroscopy (RAS), which directly depends on the complex dielectric function, enables the direct observation of electronic band structure modulation. Studying the strain-induced symmetry breaking in copper, we show how uniaxial strain lifts the degeneracy of states in the proximity of the both L and X symmetry points, thus altering the matrix element for interband optical transitions, directly observable in RAS. We corroborate our experimental results by analysing the strain-induced changes in the electronic structure based on ab-initio density functional theory calculations. The versatility to study breaking of the lattice symmetry by simple reflectance measurements opens up the possibility to gain a direct insight on the band-structure of other strain-engineered materials, such as graphene and two-dimensional (2D) transition metal dichalcogenides (TMDCs).
△ Less
Submitted 31 May, 2021; v1 submitted 9 May, 2021;
originally announced May 2021.
-
The SPOT-IL Positron Beam Construction and Its Use for Doppler Broadening Measurement of Titanium Thin Films
Authors:
P. Or,
G. Erlichman,
D. Cohen,
I. Sabo-Napadesky,
E. Gordon,
S. Cohen,
O. Presler,
E. O. Cohen,
E. Piasetzky,
H. Steinberg,
S. May-Tal Beck,
Guy Ron
Abstract:
The construction and first operation of the slow positron beam built at the Hebrew University is reported here. The beam follows a traditional design, using a 22Na source, a Tungsten moderator, and a target cell equipped with a load-lock system for easy sample insertion. The beam energy varies between 0.03 keV and 30 keV. The detection system consists of two high purity Germanium detectors, facing…
▽ More
The construction and first operation of the slow positron beam built at the Hebrew University is reported here. The beam follows a traditional design, using a 22Na source, a Tungsten moderator, and a target cell equipped with a load-lock system for easy sample insertion. The beam energy varies between 0.03 keV and 30 keV. The detection system consists of two high purity Germanium detectors, facing each other, allowing low-background Doppler-Broadening (DB) measurements. Event readout is done using a state-of-the-art compact desktop system. The target cell is designed to allow a combined measurement of DB and sample conductivity, with the flexibility to add more detection options in the future. The beam has been successfully tested by using it to charecterize Titanium (Ti) films. Two 1.2 μm Ti films -- as produced, and after annealing, were measured at various energies (2 keV - 25 keV), and the results show consistent behavior with previous measurements.
△ Less
Submitted 12 July, 2020;
originally announced July 2020.
-
The CLAS12 Backward Angle Neutron Detector (BAND)
Authors:
E. P. Segarra,
F. Hauenstein,
A. Schmidt,
A. Beck,
S. May-Tal Beck,
R. Cruz-Torres,
A. Denniston,
A. Hrnjic,
T. Kutz,
A. Nambrath,
J. R. Pybus,
K. Pryce,
C. Fogler,
T. Hartlove,
L. B. Weinstein,
J. Vega,
M. Ungerer,
H. Hakobyan,
W. K. Brooks,
E. Piasetzky,
E. Cohen,
M. Duer,
I. Korover,
J. Barlow,
E. Barriga
, et al. (3 additional authors not shown)
Abstract:
The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of $155^\circ$ to $175^\circ$, with momenta between $200$ and $600$ MeV/c. It is positioned 3 meters upstream of the target, consists of $18$ rows and $5$ layers of $7.2$ cm by $7.2$ cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers…
▽ More
The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of $155^\circ$ to $175^\circ$, with momenta between $200$ and $600$ MeV/c. It is positioned 3 meters upstream of the target, consists of $18$ rows and $5$ layers of $7.2$ cm by $7.2$ cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2 cm thick lead wall followed by a 2 cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than $250$ ps (150 ps) for energy depositions above 2 MeVee (5 MeVee). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. The time resolution results in a neutron momentum reconstruction resolution, $δp/p < 1.5$\% for neutron momentum $200\le p\le 600$ MeV/c. Final performance of the BAND with CLAS12 is shown, including electron-neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.
△ Less
Submitted 10 July, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.
-
Laser Calibration System for Time of Flight Scintillator Arrays
Authors:
A. Denniston,
E. P. Segarra,
A. Schmidt,
A. Beck,
S. May-Tal Beck,
R. Cruz-Torres,
F. Hauenstein,
A. Hrnjic,
T. Kutz,
A. Nambrath,
J. R. Pybus,
P. Toledo,
L. B. Weinstein,
M. Olivenboim,
E. Piasetzky,
I. Korover,
O. Hen
Abstract:
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neu…
▽ More
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.
△ Less
Submitted 21 May, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.