-
Overview and performance of the 2023 MUGAST@LISE campaign at GANIL
Authors:
V. Girard-Alcindor,
H. Jacob,
M. Assié,
D. Beaumel,
Y. Blumenfeld
Abstract:
MUGAST is a state-of-the-art silicon array combining trapezoidal and square shaped double-sided silicon strip detectors (DSSD) to four MUST2 telescopes. Coupled to a γ-ray spectrometer, the excellent angular coverage and compacity of the MUGAST array make it an ideal tool for the study of transfer reactions. It is a first step toward the development of the new generation of silicon arrays using pu…
▽ More
MUGAST is a state-of-the-art silicon array combining trapezoidal and square shaped double-sided silicon strip detectors (DSSD) to four MUST2 telescopes. Coupled to a γ-ray spectrometer, the excellent angular coverage and compacity of the MUGAST array make it an ideal tool for the study of transfer reactions. It is a first step toward the development of the new generation of silicon arrays using pulse shape analysis (PSA) for particle identification, such as the future GRIT array developed by our collaboration. In recent years, MUGAST has been widely used at GANIL. First with the AGATA γ-ray spectrometer and the VAMOS large acceptance spectrometer for the study of ISOL beams from the SPIRAL1 facility. It is now coupled with twelve EXOGAM clovers and to a new zero degree detection system at the end of the LISE fragmentation beamline.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.
-
Pulse shape discrimination for GRIT: beam test of a new integrated charge and current preamplifier coupled with high granularity Silicon detectors
Authors:
J. -J. Dormard,
M. Assié,
L. Grassi,
E. Rauly,
D. Beaumel,
G. Brulin,
M. Chabot,
J. -L. Coacolo,
F. Flavigny,
B. Genolini,
F. Hammache,
T. Id Barkach,
E. Rindel,
Ph. Rosier,
N. de Séréville,
E. Wanlin
Abstract:
The GRIT (Granularity, Resolution, Identification, Transparency) Silicon array is intended to measure direct reactions. Its design is based on several layers (three layers in the forward direction, two backward) of custom-made trapezoidal and square detectors. The first stage is 500 μm thick and features 128x128 orthogonal strips. Pulse shape analysis for particle identification is implemented for…
▽ More
The GRIT (Granularity, Resolution, Identification, Transparency) Silicon array is intended to measure direct reactions. Its design is based on several layers (three layers in the forward direction, two backward) of custom-made trapezoidal and square detectors. The first stage is 500 μm thick and features 128x128 orthogonal strips. Pulse shape analysis for particle identification is implemented for this first layer. Given the compacity of this array and the large number of channels involved (>7,500), an integrated preamplifier, iPACI, that gives charge and current information has been developed in the AMS 0.35 μm BiCMOS technology. The design specifications and results of the test bench are presented. Considering an energy range of 50 MeV and an energy resolution (FWHM) of 12 keV (FWHM) for the preamplifier, the energy resolution for one strip obtained from alpha source measurement in real conditions is 35 keV. The current output bandwidth is measured at 130 MHz for small signals and the power consumption reaches 40 mW per detector channel. A first beam test was performed coupling a nTD trapezoidal double-sided stripped Silicon detector of GRIT with the iPACI preamplifier and a 64-channel digitizer. Z=1 particles are discriminated with pulse shape analysis technique down to 2 MeV for protons, 2.5 MeV for deuterons and 3 MeV for tritons. The effect of the strip length due to the trapezoidal shape of the detector is investigated on both the N- and the P-side, showing no significant impact.
△ Less
Submitted 4 November, 2021;
originally announced November 2021.
-
HeCTOr: the $^3$He Cryogenic Target of Orsay for direct nuclear reactions with radioactive beams
Authors:
F. Galtarossa,
M. Pierens,
M. Assié,
V. Delpech,
F. Galet,
H. Saugnac,
D. Brugnara,
D. Ramos,
D. Beaumel,
P. Blache,
M. Chabot,
F. Chatelet,
E. Clément,
F. Flavigny,
A. Giret,
A. Gottardo,
J. Goupil,
A. Lemasson,
A. Matta,
L. Ménager,
E. Rindel
Abstract:
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scatterin…
▽ More
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scattering centers, of the order of 10$^{20}$ atoms/cm$^2$, makes it particularly suited for experiments where low-intensity radioactive beams are involved. The target was employed in a first in-beam experiment, where it was coupled to state-of-the-art gamma-ray and particle detectors. It showed excellent stability in gas temperature and density over time. Relevant experimental quantities, such as total target thickness, energy resolution and gamma-ray absorption, were determined through dedicated Geant4 simulations and found to be in good agreement with experimental data.
△ Less
Submitted 21 August, 2021; v1 submitted 12 May, 2021;
originally announced May 2021.
-
The MUGAST-AGATA-VAMOS campaign : set-up and performance
Authors:
M. Assié,
E. Clément,
A. Lemasson,
D. Ramos,
A. Raggio,
I. Zanon,
F. Galtarossa,
C. Lenain,
J. Casal,
F. Flavigny,
A. Matta,
D. Mengoni,
D. Beaumel,
Y. Blumenfeld,
R. Borcea,
D. Brugnara,
W. Catford,
F. de Oliveira,
N. De Séréville,
F. Didierjean,
C. Aa. Diget,
J. Dudouet,
B. Fernandez-Dominguez,
C. Fougères,
G. Frémont
, et al. (24 additional authors not shown)
Abstract:
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform ex…
▽ More
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform exclusive measurements of direct reactions with the radioactive beams from the SPIRAL1 facility. The performance of the set-up is described through its commissioning and two examples of transfer reactions measured during the campaign. High accuracy spectroscopy of the nuclei of interest, including cross-sections and angular distributions, is achieved through the triple-coincidence measurement. In addition, the correction from Doppler effect of the γ-ray energies is improved by the detection of the light particles and the use of two-body kinematics and a full rejection of the background contributions is obtained through the identification of heavy residues. Moreover, the system can handle high intensity beams (up to 108 pps). The particle identification based on the measurement of the time-of-flight between MUGAST and VAMOS and the reconstruction of the trajectories is investigated.
△ Less
Submitted 21 April, 2021;
originally announced April 2021.