Non-negative Matrix Factorization using Partial Prior Knowledge for Radiation Dosimetry
Authors:
Boby Lessard,
Frédéric Marcotte,
Arthur Lalonde,
François Therriault-Proulx,
Simon Lambert-Girard,
Luc Beaulieu,
Louis Archambault
Abstract:
Hyperspectral unmixing aims at decomposing a given signal into its spectral signatures and its associated fractional abundances. To improve the accuracy of this decomposition, algorithms have included different assumptions depending on the application. The goal of this study is to develop a new unmixing algorithm that can be applied for the calibration of multi-point scintillation dosimeters used…
▽ More
Hyperspectral unmixing aims at decomposing a given signal into its spectral signatures and its associated fractional abundances. To improve the accuracy of this decomposition, algorithms have included different assumptions depending on the application. The goal of this study is to develop a new unmixing algorithm that can be applied for the calibration of multi-point scintillation dosimeters used in the field of radiation therapy. This new algorithm is based on a non-negative matrix factorization. It incorporates a partial prior knowledge on both the abundances and the endmembers of a given signal. It is shown herein that, following a precise calibration routine, it is possible to use partial prior information about the fractional abundances, as well as on the endmembers, in order to perform a simplified yet precise calibration of these dosimeters. Validation and characterization of this algorithm is made using both simulations and experiments. The experimental validation shows an improvement in accuracy compared to previous algorithms with a mean spectral angle distance (SAD) on the estimated endmembers of 0.0766, leading to an average error of $(0.25 \pm 0.73)$ % on dose measurements.
△ Less
Submitted 14 June, 2024; v1 submitted 17 September, 2023;
originally announced September 2023.
-
Image registration of an electromagnetic tracking enabled afterloader and CT using a phantom for the quality control of implant reconstruction
Authors:
Isaac Neri Gomez-Sarmiento,
Daline Tho,
Christopher Dürrbeck,
Wim de Jager,
Denis Laurendeau,
Luc Beaulieu
Abstract:
Electromagnetic tracking (EMT) shows great potential for automating implant reconstruction in brachytherapy. One of the challenges of this technology is that it does not intrinsically share the same reference frame as the patient's medical imaging. The purpose of this work is to register the reference frames of an EMT-enabled afterloader and a CT scan image of a rigid phantom for quality control o…
▽ More
Electromagnetic tracking (EMT) shows great potential for automating implant reconstruction in brachytherapy. One of the challenges of this technology is that it does not intrinsically share the same reference frame as the patient's medical imaging. The purpose of this work is to register the reference frames of an EMT-enabled afterloader and a CT scan image of a rigid phantom for quality control of EMT-based implant reconstruction. The geometry of twelve 6F catheters and a tandem and ring gynecological applicator were reconstructed using an EMT sensor attached to an afterloader's check cable. All EMT reconstructions were done in three different environments: disturbance free, CT-on-rails brachytherapy suite and MRI brachytherapy suite. Implants were reconstructed using two acquisition methods: step-and-record and continuous motion. A CT scan of the phantom was obtained and manually reconstructed in the treatment planning system, with the help of the solid model of the applicator. Rigid registration algorithms were used to register EMT and CT scan reference frames using corresponding points from the EMT and CT based reconstructions of the phantom, following three approaches: one gynecological applicator, four catheters inside four calibration plates having and S-shaped path, and four ceramic marbles within the calibration plates. The absolute median deviation from the expected value for EMT measurements in all three environments significantly lie below the sensor's expected accuracy of 0.70 mm (p < 0.001), suggesting that the environment did not have a significant impact on the measurements, given that care is taken in the immediate surroundings. In all three environments, the two acquisition and three registration approaches have a mean and median registration errors (perpendicular distance) that lie at or below 1 mm, which is lower than the clinical acceptable threshold of 2 mm.
△ Less
Submitted 3 August, 2023;
originally announced August 2023.
-
Hybrid Cerenkov-scintillation detector validation using Monte Carlo simulations
Authors:
Emilie Jean,
Simon Lambert-Girard,
Francois Therriault-Proulx,
Luc Beaulieu
Abstract:
Objective: This study aimed at investigating through Monte Carlo simulations the limitations of a novel hybrid Cerenkov-scintillation detector and the associated method for irradiation angle measurements. Approach: Using Monte Carlo simulations, previous experimental irradiations of the hybrid detector with a linear accelerator were replicated to evaluate its general performances and limitations.…
▽ More
Objective: This study aimed at investigating through Monte Carlo simulations the limitations of a novel hybrid Cerenkov-scintillation detector and the associated method for irradiation angle measurements. Approach: Using Monte Carlo simulations, previous experimental irradiations of the hybrid detector with a linear accelerator were replicated to evaluate its general performances and limitations. Cerenkov angular calibration curves and irradiation angle measurements were then compared. Furthermore, the impact of the Cerenkov light energy dependency on the detector accuracy was investigated using the energy spectra of electrons travelling through the detector. Main results: Monte Carlo simulations were found to be in good agreement with experimental values. The irradiation angle absolute mean error was found to be lesser than what was obtained experimentally, with a maximum value of 1.12 degree for the 9 MeV beam. A 0.4% increase of the ratio of electrons having an energy below 1 MeV to the total electrons was found to impact the Cerenkov light intensity collected as a function of the incident angle. The effect of the Cerenkov intensity variation on the measured angle was determined to vary according to the slope of the angular calibration curve. While the contribution of scattered electrons with a lower energy affects the detector accuracy, greatest discrepancies result from the limitations of the calculation method and the calibration curve itself. Significance: A precise knowledge of the limitations of the hybrid detector and the irradiation angle calculation method is crucial for a clinical implementation. Moreover, the simulations performed in this study also corroborates hypotheses made regarding the relations between multiple Cerenkov dependencies and observations from the experimental measurements.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Technical note: On the use of polychromatic cameras for high spatial resolution spectral dose measurements
Authors:
Emily Cloutier,
Luc Beaulieu,
Louis Archambault
Abstract:
Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. The scintillation and C…
▽ More
Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. The scintillation and Cherenkov signals produced in a radioluminescent phantom are imaged by a polychromatic camera and isolated using the spectral formalism. To do so, five demosaicing algorithms are investigated from calibration to measurements: a clustering method and four interpolation algorithms. The resulting accuracy of scintillation and Cherenkov images is evaluated with measurements of the differences (mean $\pm$ standard deviation) between the obtained and expected signals from profiles drawn across a scintillation spot. Signal-to-noise ratio and signal-to-background ratio are further measured and compared in the resulting scintillation images. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively yielded differences of $3\pm6\%$, $0.1\pm0.5\%$, $0.5\pm0.5\%$, $1\pm3\%$ and $1\pm4\%$ in the resulting scintillation images. For the Cherenkov images, all algorithms provided differences below 1\%. All methods enabled measurements over the detectability (SBR>2) and sensitivity (SNR>5) thresholds with the bilinear algorithm providing the best SNR value. Hence, radioluminescent signals can accurately be isolated using a single polychromatic camera. Moreover, demosaicing using a bilinear kernel provided the best results and enabled stem effect subtraction while preserving the full spatial resolution of the camera.
△ Less
Submitted 30 November, 2021;
originally announced December 2021.
-
External beam irradiation angle measurement using Cerenkov emission
Authors:
Emilie Jean,
Simon Lambert-Girard,
Francois Therriault-Proulx,
Luc Beaulieu
Abstract:
Due to its angular dependency, Cerenkov light has long been considered a contamination signal in plastic scintillating dosimeters. In this study, we propose a novel approach designed to take advantage of this angular dependency to perform a direct measurement of an external beam radiation angle of incidence. A Cerenkov probe composed of a 10-mm long filtered sensitive volume of clear PMMA optical…
▽ More
Due to its angular dependency, Cerenkov light has long been considered a contamination signal in plastic scintillating dosimeters. In this study, we propose a novel approach designed to take advantage of this angular dependency to perform a direct measurement of an external beam radiation angle of incidence. A Cerenkov probe composed of a 10-mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1-mm diameter transport fibre. An independent PSD composed of 10-mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose. A cylindrical phantom was then used to obtain an angular calibration curve for fixed dose irradiations and perform incident angle measurements using electron and photon beams. The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves obtained for irradiation angle measurements. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86° and 1.02° at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97, 1.66, 1.45 and 0.95 degrees at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82°. The detector offers promising perspectives for external beam radiotherapy and brachytherapy applications.
△ Less
Submitted 16 March, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
External beam irradiation angle measurement using Cerenkov emission I: Signal dependencies consideration
Authors:
Emilie Jean,
Simon Lambert-Girard,
Francois Therriault-Proulx,
Luc Beaulieu
Abstract:
This study introduces a novel hybrid Cerenkov-scintillation dosimeter which is intended to be used for irradiation angle measurements based on the Cerenkov angular dependency. First measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular d…
▽ More
This study introduces a novel hybrid Cerenkov-scintillation dosimeter which is intended to be used for irradiation angle measurements based on the Cerenkov angular dependency. First measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. The Cerenkov probe is composed of a 10-mm long sensitive volume of clear PMMA optical fiber separated by an absorptive filter from a 1-mm diameter transport fiber. Filtered and raw Cerenkov signals from the sensitive volume and transport fiber, respectively, were collected using the Hyperscint RP-200 scintillation dosimetry platform. The total signal was unmixed using a hyperspectral approach. Dose calibration of the detector signal was accomplished with photon and electron beams. Using a solid-water phantom, measurements at fixed incident angles covering a wide range of doses and output factors were realized. For fixed incident angle, signal characterization of the Cerenkov detector displays a linear dose-light relationship. As expected, the sensitive volume signal was found to be energy dependent. Output factors were accurately measured within 0.8 % for field size up to 25 cm x 25 cm with both photons and electrons. First validation of the Cerenkov angular dependency shows a linear dose-light relationship for the whole range of angles tested. As expected, the Cerenkov signal intensity per dose unit varies based on the irradiation angle due to the angular dependency. Results showed that using calibration conditions where the electron energy spectrum is similar to the measurement conditions allows to rely on deposited dose to account for this dependency. These preliminary results constitute a first step toward experimental irradiation angle measurements.
△ Less
Submitted 26 January, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Accurate Dose Measurements Using Cherenkov Polarization Imaging
Authors:
Emily Cloutier,
Louis Archambault,
Luc Beaulieu
Abstract:
Purpose: Cherenkov radiation carries the potential of direct in-water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high accuracy Cherenkov dose measurements. Methods: Cherenkov produced in a 15x15x20 cm^3 water tank is imaged with a cooled CCD camera from four polarizer transmission…
▽ More
Purpose: Cherenkov radiation carries the potential of direct in-water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high accuracy Cherenkov dose measurements. Methods: Cherenkov produced in a 15x15x20 cm^3 water tank is imaged with a cooled CCD camera from four polarizer transmission axes [0°, 45°, 90°, 135°]. The water tank is positioned at the isocenter of a 5x5 cm^2, 6 MV photon beam. Using Malus' law, the polarized portion of the signal is extracted. Corrections are applied to the polarized signal following azimuthal and polar Cherenkov angular distributions extracted from Monte Carlo simulations. Percent depth dose and beam profiles are measured and compared with the prediction from a treatment planning system (TPS). Results: Corrected polarized signals on the central axis reduced deviations at depth from 20% to 0.8\pm1%. For the profile measurement, differences between the corrected polarized signal and the TPS calculations are 1\pm3% and 8\pm3% on the central axis and penumbra regions respectively. 29\pm1% of the Cherenkov signal was found to be polarized. Conclusions: This work proposes a novel polarization imaging approach enabling high precision water-based Cherenkov dose measurements. The method allows correction of the Cherenkov anisotropy within 3% on the beam central axis and in depth.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
Performance of an Enhanced Afterloader with Electromagnetic Tracking Capabilities for Channel Reconstruction and Error Detection
Authors:
Daline Tho,
Marie-Claude Lavallée,
Luc Beaulieu
Abstract:
The reconstruction and error detection performance of a Flexitron research unit equipped with a special check-cable in which is integrated an EM sensor (NDI Aurora V3) that enables tracking and reconstruction capability was assessed. Reconstructions of a 24 cm long catheter were performed using two methods: continuous fixed speed check cable backward step** and step** through each dwell positi…
▽ More
The reconstruction and error detection performance of a Flexitron research unit equipped with a special check-cable in which is integrated an EM sensor (NDI Aurora V3) that enables tracking and reconstruction capability was assessed. Reconstructions of a 24 cm long catheter were performed using two methods: continuous fixed speed check cable backward step** and step** through each dwell position every 1mm. The ability of the system to differentiate between two closely located (parallel) catheters was investigated by connecting catheters to the afterloader and moving it from its axis with an increment of 1mm. A robotic arm was used to move the catheter between each reconstruction. Reconstructions were obtained with a locally weighted scatter-plot smoothing algorithm. To quantify the reconstruction accuracy, distances between two catheters were computed along the reconstruction track with a 5mm step. Reconstructions of curve catheter paths were assessed through parallel and perpendicular phantom configuration to the EM field generator. Indexer length and lateral error were simulated and ROC analysis was made. Using a 50cm/s check cable speed does not allow accurate reconstruction. A slower check cable speed results in better reconstruction performance and smaller standard deviations. The optimum operating distance from the field generator (50-300mm) resulted in a lower absolute mean deviation from the expected value (0.2pm0.1mm) versus being positioned on the edge of the electromagnetic sensitive detection volume (0.6pm0.3mm). Reconstructions of curved and circular paths with a check cable speed under 5cm/s gave a 0.8pm0.5mm error, or better. All indexer and lateral shifts of 1mm were detected with a check cable speed of 2.5cm/s or under. A speed under 5cm/s is recommended for straight and curved catheter reconstructions. The check cable can also be used to detect common shift errors.
△ Less
Submitted 12 May, 2021;
originally announced May 2021.
-
Deformable Scintillation Dosimeter II: Real-Time Simultaneous Measurements of Dose and Tracking of Deformation Vector Fields
Authors:
Emily Cloutier,
Luc Beaulieu,
Louis Archambault
Abstract:
Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose distributions from one image set to another. However, the lack of validation tools slows their clinical adoption, despite their commercial availability. This wor…
▽ More
Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose distributions from one image set to another. However, the lack of validation tools slows their clinical adoption, despite their commercial availability. This work presents a novel water-equivalent deformable dosimeter that simultaneously measures the dose distribution and tracks deformation vector fields (DVF). The dosimeter in made of an array of 19 scintillating fiber detectors embedded in a cylindrical elastomer matrix. It is imaged by two pairs of stereoscopic cameras tracking the position and angulation of the scintillators, while measuring the dose. The resulting system provides a precision of 0.3 mm on DVF measurements. The dosimeter was irradiated with 5$\times$3, 4$\times$3 and 3$\times$3 cm$^2$ 6 MV photon beams in both fixed and deformed conditions. The measured DVF was compared to the one computed with a DIR algorithm (Plastimatch). The deviations between the computed and measured DVFs was below 1.5 mm. As for dose measurements, the dosimeter acquired the dose distribution in fixed and deformed conditions within 1\% of the treatment planning system calculation and complementary dose validation using the Hyperscint dosimetry system. Using the demonstrated qualities of scintillating detectors, we developed a real-time, water-equivalent deformable dosimeter. Given it's sensor tracking position precision and dose measurements accuracy, the developed detector is a promising tools for the validation of DIR algorithms as well as dose distribution measurements under fixed and deformed conditions.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Deformable Scintillation Dosimeter I: Challenges and Implementation using Computer Vision Techniques
Authors:
Emily Cloutier,
Louis Archambault,
Luc Beaulieu
Abstract:
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional detectors, especially in complex irradiation geometries. Their range of applications could be further extended by embedding scintillators in a deformable matrix mimick…
▽ More
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional detectors, especially in complex irradiation geometries. Their range of applications could be further extended by embedding scintillators in a deformable matrix mimicking anatomical changes. In this work, we characterized signal variations arising from the translation and rotation of scintillating fibers with respect to a camera. Corrections are proposed using stereo vision techniques and two sCMOS complementing a CCD camera. The study was extended to the case of a prototype real-time deformable dosimeter comprising an array of 19 scintillating. The signal to angle relationship follows a gaussian distribution (FWHM = 52°) whereas the intensity variation from radial displacement follows the inverse square law. Tracking the position and angle of the fibers enabled the correction of these spatial dependencies. The detecting system provides an accuracy and precision of respectively 0.008 cm and 0.03 cm on the position detection. This resulted in an uncertainty of 2° on the angle measurement. Displacing the dosimeter by $\pm$3 cm in depth resulted in relative intensities of 100$\pm$10% (mean $\pm$ standard deviation) to the reference position. Applying corrections reduced the variations thus resulting in relative intensities of 100$\pm$1%. Similarly, for lateral displacements of $\pm$3 cm, intensities went from 98$\pm$3% to 100$\pm$1% after the correction. Therefore, accurate correction of the signal collected by a camera imaging the output of scintillating elements in a 3D volume is possible. This work paves the way to the development of real-time scintillator-based deformable dosimeters.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Comparative optic and dosimetric characterization of the HYPERSCINT scintillation dosimetry research platform for multipoint applications
Authors:
Emilie Jean,
Francois Therriault-Proulx,
Luc Beaulieu
Abstract:
This study introduces the HYPERSCINT research platform, the first commercially available scintillation dosimetry platform capable of multi-point dosimetry through the hyperspectral approach. Optic and dosimetric performances of the system were investigated through comparison with another commercially available solution, the Ocean Optics QE65Pro spectrometer. The optical characterization was accomp…
▽ More
This study introduces the HYPERSCINT research platform, the first commercially available scintillation dosimetry platform capable of multi-point dosimetry through the hyperspectral approach. Optic and dosimetric performances of the system were investigated through comparison with another commercially available solution, the Ocean Optics QE65Pro spectrometer. The optical characterization was accomplished by measuring the linearity of the signal as a function of integration time, photon detection efficiency and spectral resolution for both systems. Dosimetric performances were then evaluated with a 3-point plastic scintillator detector (mPSD) in terms of signal to noise ratio (SNR) and signal to background ratio (SBR) associated with each scintillator. The latter were subsequently compared with those found in the literature for the Exradin W1, a single-point plastic scintillator detector. Finally, various beam measurements were realized with the HYPERSCINT platform to evaluate its ability to perform clinical photon beam dosimetry. Both systems were found to be comparable in terms of linearity of the signal as a function of the intensity. Although the QE65Pro possesses a higher spectral resolution, the detection efficency of the HYPERSCINT is up to 1000 time greater. Dosimetric measurements shows that the latter also offers a better SNR and SBR, surpassing even the SNR of the Exradin W1 single-point PSD. While the doses ranging from 1 cGy to 600 cGy were accurately measured within 2.1% of the predicted dose using the HYPERSCINT platform coupled to the mPSD, the Ocean optics spectrometer shows discrepencies up to 86% under 50cGy. Similarly, depth dose, full width at half maximum region of the beam profile and output factors were all accurately measured within 2.3% of the predicted dose using the HYPERSCINT platform and exhibit an average difference of 0.5%, 1.6% and 0.6%, respectively.
△ Less
Submitted 22 March, 2021; v1 submitted 30 October, 2020;
originally announced November 2020.
-
3D source tracking and error detection in HDR using two independent scintillator dosimetry systems
Authors:
Haydee M. Linares Rosales,
Jacob G. Johansen,
Gustavo Kertzscher,
Kari Tanderup,
Luc Beaulieu,
Sam Beddar
Abstract:
The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose. Previous studies to this one, have characterized potential detectors that can be used as in vivo dosimeter. Some of them have focused on the source tracking topi…
▽ More
The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose. Previous studies to this one, have characterized potential detectors that can be used as in vivo dosimeter. Some of them have focused on the source tracking topic in HDR brachytherapy. The aim of this study is to perform 3D source position reconstruction by combining in vivo dosimetry measurements from two independent detector systems. The first was based on multiple (three) plastic scintillator detectors and the second on a single inorganic crystal (CsI:Tl). By combining two detector responses, we enabled the determination of the absolute source coordinates in 3D space. The method in this study proposed can be extended to the combination of different systems.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy
Authors:
Haydee M. Linares Rosales,
Audrey Cantin,
Sylviane Aubin,
Sam Beddar,
Luc Beaulieu
Abstract:
This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized multi-point plastic scintillator dosimeter (3 points mPSD; using BCF-60, BCF-12, and BCF-10 scintillators), 2) a compact assembly of photomultiplier tubes (PMTs)…
▽ More
This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized multi-point plastic scintillator dosimeter (3 points mPSD; using BCF-60, BCF-12, and BCF-10 scintillators), 2) a compact assembly of photomultiplier tubes (PMTs) coupled to dichroic mirrors and filters for high-sensitivity scintillation light collection, and 3) a Python-based graphical user interface used for system management and signal processing. IViST can simultaneously measure dose, triangulate source position, and measure dwell time. By making 100 000 measurements/s, IViST samples enough data to quickly perform key QA/QC tasks such as identifying wrong individual dwell time or interchanged transfer tubes. By using 3 co-linear sensors and planned information for an implant geometry (from DICOM RT), the platform can also triangulate source position in real-time. A clinical trial is presently on-going using the IViST system.
△ Less
Submitted 14 June, 2020;
originally announced June 2020.
-
Light-Generating CdSe/CdS Colloidal Quantum Dot-Doped Plastic Optical Fibers
Authors:
Carly A. Whittaker,
Arthur Perret,
Charles W. Fortier,
Olivier-Michel Tardif,
Sébastien A. Lamarre,
Steeve Morency,
Dominic Larivière,
Luc Beaulieu,
Younès Messaddeq,
Claudine Nì. Allen
Abstract:
Colloidal quantum dots (cQDs) are now a mature nanomaterial with optical properties customizable through varying size and composition. However, their use in optical devices is limited as they are not widely available in convenient forms such as optical fibers. With advances in polymerization methods incorporating nanocrystals, nanocomposite materials suitable for processing into high quality hybri…
▽ More
Colloidal quantum dots (cQDs) are now a mature nanomaterial with optical properties customizable through varying size and composition. However, their use in optical devices is limited as they are not widely available in convenient forms such as optical fibers. With advances in polymerization methods incorporating nanocrystals, nanocomposite materials suitable for processing into high quality hybrid active fibers can be achieved. We demonstrate a plastic optical fiber fabrication method which ensures homogeneous dispersion of cQDs within a polymer core matrix. Loading concentrations between 10$^{11}$-10$^{13}$ CdSe/CdS cQDs per cm$^{3}$ in polystyrene were electronically imaged, confirming only sporadic sub-wavelength aggregates. Rayleigh scattering losses are therefore dominant at energies below the semiconductors' band gap, but are overtaken by a sharp CdS-related absorption onset around 525 nm facilitating cQD excitation. The redshifted photoluminescence emission is then minimally reabsorbed along the fiber with a spectrum barely affected by the polymerization and a quantum yield staying at $\sim$65$\%$ of its initial value. The latter, along with the glass transition temperature and refractive index, is independent of the cQD concentration hence yielding a proportionally increasing light output. Our cQD-doped fibers are photostable to within 5$\%$ over days showing great promise for functional material applications.
△ Less
Submitted 6 June, 2020;
originally announced June 2020.
-
On the use of machine learning methods for mPSD calibration in HDR brachytherapy
Authors:
Haydee M. Linares Rosales,
Gabriel Couture,
Louis Archambault,
Sam Beddar,
Philippe Despres,
Luc Beaulieu
Abstract:
Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various…
▽ More
Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various positions in a homemade PMMA holder. Dose measurements covering a range of 0.5 to 12 cm of source displacement were carried out according to TG-43 recommendations. Individual scintillator doses were decoupled using a linear regression model, a random forest estimator, and artificial neural network algorithms. The performance of the different algorithms was evaluated using different sample sizes and distances to the source for the mPSD system calibration. Results: The decoupling methods' deviations from the expected TG-43 dose generally remained below 20%. However, the dose prediction with the three algorithms was accurate to within 7% relative to the dose predicted by the TG-43 formalism for measurements performed in the same range of distances used for calibration. The performance random forest was compromised when the predictions were done beyond the range of distances used for calibration. The dose prediction by the linear regression was less influenced by the calibration conditions than random forest, but with more significant deviations. The number of available measurements for training purposes influenced the random forest and neural network models the most. Their accuracy tended to converge toward deviation values close to 1% from a number of dwell positions greater than 100. Conclusions: In performing HDR brachytherapy dose measurements with an optimized mPSD system, ML algorithms are good alternatives for precise dose reporting and treatment assessment.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.
-
Dosimetric performance of a multi-point plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate brachytherapy
Authors:
Haydee M. Linares Rosales,
Louis Archambault,
Sam Beddar,
Luc Beaulieu
Abstract:
Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy measurements (using the scintillators BCF-60, BCF-12, and BCF-10). The light detection system of the mPSD consisted of compactly assembled photomultiplier tubes (PMTs…
▽ More
Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy measurements (using the scintillators BCF-60, BCF-12, and BCF-10). The light detection system of the mPSD consisted of compactly assembled photomultiplier tubes (PMTs) and dichroic mirrors and filters to achieve a highly sensitive scintillation light collection. The PMT signals were recorded using a NI-DAQ board at a rate of 100 kHz. Dose measurements covering a range of 0.5 to 10 cm from the 192Ir source were carried out according to TG-43 U1 recommendations in order to: (1) characterize the system's response in terms of angular dependence; (2) obtain the relative contribution of positioning and measurement uncertainties to the total system uncertainty; (3) assess the system's temporal resolution; and (4) track the source position in real time. Results: The positioning uncertainty dominated close to the source, whereas the measurement uncertainty dominated at larger distances. A maximum measurement uncertainty of 17 % was observed for the BCF-60 scintillator at 10 cm from the source. The average best compromise between positioning and measurement uncertainties were reached at 17.4 mm. The detector further exhibited no angular dependence. The system provided an average location with a standard deviation under 1.7 mm. The maximum observed differences between measured and expected source location was 1.82 mm. Dose deviations remained below 5% in all the explored measurement conditions. With regard to dwell time measurement accuracy, the maximum deviation observed at all distances was 0.56 s. Conclusions: The performance of the system demonstrated that it could be used for real-time dose, position and dwell time measurements during HDR brachytherapy.
△ Less
Submitted 28 October, 2019;
originally announced October 2019.
-
A GPU-based multi-criteria optimization algorithm for HDR brachytherapy
Authors:
Cédric Bélanger,
Songye Cui,
Yunzhi Ma,
Philippe Després,
J. Adam M. Cunha,
Luc Beaulieu
Abstract:
Currently in HDR brachytherapy planning, a manual fine-tuning of an objective function is necessary to obtain case-specific valid plans. This study intends to facilitate this process by proposing a patient-specific inverse planning algorithm for HDR prostate brachytherapy: GPU-based multi-criteria optimization (gMCO).
Two GPU-based optimization engines including simulated annealing (gSA) and a q…
▽ More
Currently in HDR brachytherapy planning, a manual fine-tuning of an objective function is necessary to obtain case-specific valid plans. This study intends to facilitate this process by proposing a patient-specific inverse planning algorithm for HDR prostate brachytherapy: GPU-based multi-criteria optimization (gMCO).
Two GPU-based optimization engines including simulated annealing (gSA) and a quasi-Newton optimizer (gL-BFGS) were implemented to compute multiple plans in parallel. After evaluating the equivalence and the computation performance of these two optimization engines, one preferred optimization engine was selected for the gMCO algorithm. Five hundred sixty-two previously treated prostate HDR cases were divided into validation set (100) and test set (462). In the validation set, the number of Pareto optimal plans to achieve the best plan quality was determined for the gMCO algorithm. In the test set, gMCO plans were compared with the physician-approved clinical plans.
Over 462 cases, the number of clinically valid plans was 428 (92.6%) for clinical plans and 461 (99.8%) for gMCO plans. The number of valid plans with target V100 coverage greater than 95% was 288 (62.3%) for clinical plans and 414 (89.6%) for gMCO plans. The mean planning time was 9.4 s for the gMCO algorithm to generate 1000 Pareto optimal plans.
In conclusion, gL-BFGS is able to compute thousands of SA equivalent treatment plans within a short time frame. Powered by gL-BFGS, an ultra-fast and robust multi-criteria optimization algorithm was implemented for HDR prostate brachytherapy. A large-scale comparison against physician approved clinical plans showed that treatment plan quality could be improved and planning time could be significantly reduced with the proposed gMCO algorithm.
△ Less
Submitted 2 April, 2019;
originally announced April 2019.
-
Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy
Authors:
Daline Tho,
Luc Beaulieu
Abstract:
Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic…
▽ More
Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0° and 90°.To test the dependence for each sensor, the signal measurement were taken from 0° to 90° with 10$°$ increment. The 5PCBDOF sensor showed an increased signal of almost $20{\%}$ with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of $\pm$ 0.06 mm and a reproductibility of$ {\pm}$ 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1$°$. It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5${\%}$.
△ Less
Submitted 22 December, 2018;
originally announced December 2018.
-
Investigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry
Authors:
Emilie Jean,
Marie-Eve Delage,
Luc Beaulieu
Abstract:
Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distill…
▽ More
Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distilled water at various concentrations (0.01 to 1.2 g/L). The solutions were irradiated with photon beams at 6 and 23 MV. The dependence of the light produced as a function of sample concentration was studied using a spectrometer with a fixed integration time. Spectral measurements of the luminescent solution and the blank solution (distilled water only) were taken to deconvolve the Cherenkov and quinine contribution to the overall emission spectrum. Using a CCD camera, intensity profiles were obtained for the blank and the 1.00 g/L solutions to compare them with the dose predicted by a treatment planning system. The luminescent intensity of the samples was found to follow a logarithmic trend as a function of the quinine concentration. Based on the spectral deconvolution of the 1.00 g/L solution, 52.4% and 52.7% of the signal in the visible range results from the quinine emission at 6 and 23 MV, respectively. The remaining fraction of the spectrum is due to the Cherenkov light that has not been converted. The fraction of the Cherenkov emission produced between 250 nm and 380 nm in the water and that was absorbed by the fluorophore reached 24.8% and 9.4% respectively at 6 and 23 MV. X-ray stimulated fluorescence of the quinine was then proven to be the principal cause to the increased total light output compared to the water-only signal. This new information reinforces the direct correlation of the solution intensity to the dose deposition.
△ Less
Submitted 20 May, 2019; v1 submitted 6 September, 2018;
originally announced September 2018.
-
Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy
Authors:
Haydee M. Linares Rosales,
Patricia Duguay-Drouin,
Louis Archambault,
Sam Beddar,
Luc Beaulieu
Abstract:
Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the scintillation light collection produced by the interaction of ionizing photons. Several mPSD prototypes were built and tested in order to determine the appropriate order…
▽ More
Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the scintillation light collection produced by the interaction of ionizing photons. Several mPSD prototypes were built and tested in order to determine the appropriate order of scintillators relative to the photodetector, as well as their length as a function of the scintillation light emitted. Scintillators BCF-60, BCF-12 and BCF-10 constituted the mPSD sensitive volume.Each scintillator contribution to the total spectrum was determined by irradiations in the low energy range.For the best mPSD design, a numerical optimization was done in order to select the optical components that better match the light emission profile. The optimized dosimetric system was used for HDR brachytherapy dose determination. The system performance was quantified in term of signal to noise ratio and signal to background ratio. Results: It was determined that BCF-60 should be placed at the distal position, BCF-12 in the center and BCF-10 at proximal position with respect to the photodetector.This configuration allowed for optimized light transmission through the collecting fiber, avoiding inter-scintillator excitation and self-absorption effects.The optimized luminescence system allowed for signal deconvolution using a multispectral approach, extracting the dose to each element while taking into account Cerenkov stem effect.Differences between the mPSD measurements and TG-43 remain below 5%. In all measurement conditions, the system was able to properly differentiate the produced scintillation signal from the background one. Conclusions: A mPSD was constructed and optimized for HDR brachytherapy dosimetry, enabling real time dose determination, up to 6.5cm from the 192Ir source.
△ Less
Submitted 31 May, 2019; v1 submitted 24 July, 2018;
originally announced July 2018.
-
On EM Reconstruction of a Multi Channel Shielded Applicator for Cervical Cancer Brachytherapy: A Feasibility Study
Authors:
D. Tho,
E. Racine,
H. Easton,
W. Y. Song,
L. Beaulieu
Abstract:
Electromagnetic tracking (EMT) is a promising technology for automated catheter and applicator reconstruc- 10 tions in brachytherapy. In this work, a proof-of-concept is presented for reconstruction of the individual channels of a shielded tandem applicator dedicated to intensity modulated brachytherapy. All six channels of a straight prototype was reconstructed and the distance between two opposi…
▽ More
Electromagnetic tracking (EMT) is a promising technology for automated catheter and applicator reconstruc- 10 tions in brachytherapy. In this work, a proof-of-concept is presented for reconstruction of the individual channels of a shielded tandem applicator dedicated to intensity modulated brachytherapy. All six channels of a straight prototype was reconstructed and the distance between two opposite channels was measured. A study was also conducted on the influence of the shield on the data fluctuation of the EMT system. The differences with the CAD specified dimensions are under 2 mm. The pair of channels which has one of it more distant from the generator have 15 higher inter-channel distance with higher variability. In the first 110 cm reconstruction, all inter-channel distances are within the geometrical tolerances. According to a paired Student t-test, the data given by the EM system with and without the shield applicator tip are not significantly different. This study shows that the reconstruction of channel path within the mechanical accuracy of the applicator is possible.
△ Less
Submitted 3 October, 2017;
originally announced October 2017.
-
A theoretical framework to predict the most likely ion path in particle imaging
Authors:
Charles-Antoine Collins-Fekete,
Lennart Volz,
Stephen K. N. Portillo,
Luc Beaulieu,
Joao Seco
Abstract:
In this work, a generic rigorous Bayesian formalism is introduced to predict the most likely path of any ion crossing a medium between two detection points. The path is predicted based on a combination of the particle scattering in the material and measurements of its initial and final position, direction and energy. The path estimate's precision is compared to the Monte Carlo simulated path. Ever…
▽ More
In this work, a generic rigorous Bayesian formalism is introduced to predict the most likely path of any ion crossing a medium between two detection points. The path is predicted based on a combination of the particle scattering in the material and measurements of its initial and final position, direction and energy. The path estimate's precision is compared to the Monte Carlo simulated path. Every ion from hydrogen to carbon is simulated in two scenarios to estimate the accuracy achievable: one where the range is fixed and one where the initial velocity is fixed. In the scenario where the range is kept constant, the maximal root-mean-square error between the estimated path and the Monte Carlo path drops significantly between the proton path estimate (0.50 mm) and the helium path estimate (0.18 mm), but less so up to the carbon path estimate (0.09 mm). In the scenario where the initial velocity is kept constant, helium have systematically the minimal root-mean-square error throughout the path. As a result, helium is found to be the optimal particle for ion imaging.
△ Less
Submitted 18 October, 2016;
originally announced October 2016.