Rotary Excitation of non-sinusoidal pulsed magnetic fields: Towards non-invasive direct detection of cardiac conduction
Authors:
Petra Albertova,
Maximilian Gram,
Martin Blaimer,
Wolfgang R Bauer,
Peter M Jakob,
Peter Nordbeck
Abstract:
Purpose: In the recent past, spin-locking MRI experiments were successfully applied for the direct detection of sinusoidal magnetic field oscillations in the sub-nT range. In the present study, this detection approach was extended to non-sinusoidal pulsed magnetic fields based on the Rotary Excitation (REX) mechanism. Methods: The new detection concept was examined by means of Bloch simulations, e…
▽ More
Purpose: In the recent past, spin-locking MRI experiments were successfully applied for the direct detection of sinusoidal magnetic field oscillations in the sub-nT range. In the present study, this detection approach was extended to non-sinusoidal pulsed magnetic fields based on the Rotary Excitation (REX) mechanism. Methods: The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin-locked magnetization and low-frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3T. Gaussian and Sinc-shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a Magnetocardiogram, was tested. Results: Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin-lock frequency coincides with a non-zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude (R2>0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS-like fields with varying QRS durations yielded significant results in a phantom setup (p<0.001). Conclusion: REX detection can be transferred to non-sinusoidal pulsed magnetic fields and could provide a non-invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.
△ Less
Submitted 26 April, 2024; v1 submitted 24 November, 2023;
originally announced November 2023.
-
Three-dimensional assessment of susceptibility-induced signal voids caused by active cardiac implants in the setting of 3.0T CMR
Authors:
Theresa Reiter,
Ingo Weiss,
Oliver M. Weber,
Wolfgang R. Bauer
Abstract:
Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence…
▽ More
Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence, multi-slice 2D turbo spin echo sequence), as well as reference sequences according to the ASTM were applied. Four representative active cardiac devices and a generic setup were analysed regarding volume and shape of the signal void. For analysis, a threshold operation applied to the grey value profle of each data data set was used. The presented approach allows the evaluation of signal void and shape even for larger implants such as ICDs. The void shape is influenced by the orientation of the B0-field and the chosen sequence type, as well as the distribution of magnetic material within the implants. The void volume depends both on the device itself, and the sequence type. Disturbances in the B0 and B1 fields exceed the visual signal void. This work presents a reproducible and highly defined approach towards characterising both signal void artifacts at 3.0T and their influencing factors.
△ Less
Submitted 2 April, 2022; v1 submitted 1 August, 2021;
originally announced August 2021.
-
An analytical Model which Determines the Apparent T1 for Modified Look-Locker Inversion Recovery (MOLLI) -- Analysis of the Longitudinal Relaxation under the Influence of Discontinuous Balanced and Spoiled Gradient Echo Readouts
Authors:
Thomas Kampf,
Theresa Reiter,
Wolfgang Rudolf Bauer
Abstract:
Quantitative nuclear magnetic resonance imaging (MRI) shifts more and more into the focus of clinical research. Especially determination of relaxation times without/and with contrast agents becomes the foundation of tissue characterization, e.g. in cardiac MRI for myocardial fibrosis. Techniques which assess longitudinal relaxation times rely on repetitive application of readout modules, which are…
▽ More
Quantitative nuclear magnetic resonance imaging (MRI) shifts more and more into the focus of clinical research. Especially determination of relaxation times without/and with contrast agents becomes the foundation of tissue characterization, e.g. in cardiac MRI for myocardial fibrosis. Techniques which assess longitudinal relaxation times rely on repetitive application of readout modules, which are interrupted by free relaxation periods, e.g. the Modified Look-Locker Inversion Recovery = MOLLI sequence. These discontinuous sequences reveal an apparent relaxation time, and, by techniques extrapolated from continuous readout sequences, the real T1 is determined. What is missing is a rigorous analysis of the dependence of the apparent relaxation time on its real partner, readout sequence parameters and biological parameters as heart rate. This is provided in this paper for the discontinuous balanced steady state free precession (bSSFP) and spoiled gradient echo readouts. It turns out that the apparente longitudinal relaxation rate is the time average of the relaxation rates during the readout module, and free relaxation period. Knowing the heart rate our results vice versa allow to determine the real T1 from its measured apparent partner.
△ Less
Submitted 16 October, 2018; v1 submitted 23 April, 2017;
originally announced April 2017.
-
Dynamics and Efficiency of Brownian Rotors
Authors:
Wolfgang R. Bauer,
Walter Nadler
Abstract:
Brownian rotors play an important role in biological systems and in future nano-technological applications. However the mechanisms determining their dynamics, efficiency and performance remain to be characterized. Here the F0 portion of the F-ATP synthase is considered as a paradigm of a Brownian rotor. In a generic analytical model we analyze the stochastic rotation of F0-like motors as a funct…
▽ More
Brownian rotors play an important role in biological systems and in future nano-technological applications. However the mechanisms determining their dynamics, efficiency and performance remain to be characterized. Here the F0 portion of the F-ATP synthase is considered as a paradigm of a Brownian rotor. In a generic analytical model we analyze the stochastic rotation of F0-like motors as a function of the driving free energy difference and of the free energy profile the rotor is subjected to. The latter is composed of the rotor interaction with its surroundings, of the free energy of chemical transitions, and of the workload. The dynamics and mechanical efficiency of the rotor depends on the magnitude of its stochastic motion driven by the free energy energy difference and its rectification on the reaction-diffusion path. We analyze which free energy profiles provide maximum flow and how their arrangement on the underlying reaction-diffusion path affects rectification and -- by this -- the efficiency.
△ Less
Submitted 10 November, 2008;
originally announced November 2008.
-
Theory of Coherent and Incoherent Nuclear Spin-Dephasing in the Heart
Authors:
Wolfgang R. Bauer,
Walter Nadler,
Michael Bock,
Lothar R. Schad,
Christian Wacker,
Andreas Hartlep,
Georg Ertl
Abstract:
We present an analytical theory of susceptibility induced nuclear spin dephasing in the capillary network of myocardium. Using a strong collision approach, equations are obtained for the relaxation rate of the free induction and the spin echo decay. Simulation and experimental data are well predicted by the theory. Since paramagnetic deoxyhemoglobin as the origin of nuclear spin dephasing has a…
▽ More
We present an analytical theory of susceptibility induced nuclear spin dephasing in the capillary network of myocardium. Using a strong collision approach, equations are obtained for the relaxation rate of the free induction and the spin echo decay. Simulation and experimental data are well predicted by the theory. Since paramagnetic deoxyhemoglobin as the origin of nuclear spin dephasing has a higher tissue concentration in myocardium supplied by a stenotic, i. e. significantly narrowed, coronary artery, spin dephasing might serve as a diagnostic tool. Our approach can be modified for capillary networks in other tissues than myocardium and may be applied in material science.
△ Less
Submitted 1 October, 1999;
originally announced October 1999.