Skip to main content

Showing 1–3 of 3 results for author: Bauer, J M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2102.11372  [pdf

    cond-mat.mes-hall cond-mat.mtrl-sci physics.optics

    Twist-angle engineering of excitonic quantum interference and optical nonlinearities in stacked 2D semiconductors

    Authors: Kai-Qiang Lin, Paulo E. Faria Junior, Jonas M. Bauer, Bo Peng, Bartomeu Monserrat, Martin Gmitra, Jaroslav Fabian, Sebastian Bange, John M. Lupton

    Abstract: Twist-engineering of the electronic structure of van-der-Waals layered materials relies predominantly on band hybridization between layers. Band-edge states in transition-metal-dichalcogenide semiconductors are localized around the metal atoms at the center of the three-atom layer and are therefore not particularly susceptible to twisting. Here, we report that high-lying excitons in bilayer WSe2 c… ▽ More

    Submitted 22 February, 2021; originally announced February 2021.

    Journal ref: Nature Communications 12, 1553 (2021)

  2. The BaBar Electromagnetic Calorimeter: Status and Performance Improvements

    Authors: Johannes M. Bauer

    Abstract: The electromagnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with high resolution. The current status of the calorimeter, now in its seventh year of operation, is being presented, as well as details on improvements made to the analysis code during the last years.

    Submitted 18 January, 2006; originally announced January 2006.

    Comments: 6 pages, 15 figures, presented at the 2005 IEEE Nuclear Science Symposium and submitted to the Conference Proceedings of the 2005 IEEE Nuclear Science Symposium

    Report number: SLAC-PUB-11578, BABAR-TALK-05/145

    Journal ref: IEEENucl.Sci.Symp.Conf.Rec.2:1038-1042,2006

  3. arXiv:physics/0312128  [pdf, ps, other

    physics.ins-det hep-ex

    Absolute Energy Calibration with the Neutron-Activated Liquid-Source System at BaBar's CsI(Tl) Calorimeter

    Authors: Johannes M. Bauer

    Abstract: The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13 MeV photons obtained from a liquid source system. During the calibration, a fluorine-rich liquid is activated via a neutron generator and pumped past the fron… ▽ More

    Submitted 21 December, 2003; originally announced December 2003.

    Comments: 7 pages, 14 figures, presented at 2003 IEEE Nuclear Science Symposium, submitted to IEEE Transactions on Nuclear Science

    Report number: SLAC-PUB-10289, UMS-HEP-2003-027

    Journal ref: IEEE Trans.Nucl.Sci. 51 (2004) 1596