-
Full-Field Nanoscale X-ray Diffraction-Contrast Imaging using Direct Detection
Authors:
Elliot Kisiel,
Ishwor Poudyal,
Peter Kenesei,
Mark Engbretson,
Arndt Last,
Rourav Basak,
Ivan Zaluzhnyy,
Uday Goteti,
Robert Dynes,
Antonino Miceli,
Alex Frano,
Zahir Islam
Abstract:
Recent developments in x-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field x-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films proves challenging due to available detection methods and incident x-ray flux at the sample. We presen…
▽ More
Recent developments in x-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field x-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films proves challenging due to available detection methods and incident x-ray flux at the sample. We present a direct detection method focusing on DFXM studies in the hard x-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.
△ Less
Submitted 4 January, 2023; v1 submitted 14 December, 2022;
originally announced December 2022.
-
Mobility of bacterial protein Hfq on dsDNA; Role of C-terminus mediated transient binding
Authors:
Chuan Jie Tan,
Rajib Basak,
Indresh Yadav,
Jeroen A. van Kan,
Veronique Arluison,
Johan R. C. van der Maarel
Abstract:
The mobility of protein is fundamental in the machinery of life. Here, we have investigated the effect of DNA binding in conjunction with DNA internal motion of the bacterial Hfq master regulator devoid of its amyloid C-terminus domain. Hfq is one of the most abundant nucleoid associated proteins that shape the bacterial chromosome and is involved in several aspects of nucleic acid metabolism. Flu…
▽ More
The mobility of protein is fundamental in the machinery of life. Here, we have investigated the effect of DNA binding in conjunction with DNA internal motion of the bacterial Hfq master regulator devoid of its amyloid C-terminus domain. Hfq is one of the most abundant nucleoid associated proteins that shape the bacterial chromosome and is involved in several aspects of nucleic acid metabolism. Fluorescence microscopy has been used to track a C-terminus domain lacking mutant form of Hfq on double stranded DNA, which is stretched by confinement to a rectangular nanofluidic channel. The mobility of the mutant is strongly accelerated with respect to the wild type variant. Furthermore, it shows a reverse dependence on the internal motion of DNA, in that slower motion results in slower protein diffusion. Results demonstrate the subtle role of DNA internal motion in controlling the mobility of a nucleoid associated protein, and, in particular, the importance of transient binding and moving DNA strands out of the way.
△ Less
Submitted 6 December, 2021;
originally announced December 2021.
-
Charged Particle Monitor on the AstroSat mission
Authors:
A. R. Rao,
M. H. Patil,
Yash Bhargava,
Rakesh Khanna,
M. K. Hingar,
A. P. K. Kutty,
J. P. Malkar,
Rupal Basak,
S. Sreekumar,
Essy Samuel,
P. Priya,
P. Vinod,
D. Bhattacharya,
V. Bhalerao,
S. V. Vadawale,
N. P. S. Mithun,
R. Pandiyan,
K. Subbarao,
S. Seetha,
K. Suryanarayana Sarma
Abstract:
Charged Particle Monitor (CPM) on-board the AstroSat satellite is an instrument designed to detect the flux of charged particles at the satellite location. A Cesium Iodide Thallium (CsI(Tl)) crystal is used with a Kapton window to detect protons with energies greater than 1 MeV. The ground calibration of CPM was done using gamma-rays from radioactive sources and protons from particle accelerators.…
▽ More
Charged Particle Monitor (CPM) on-board the AstroSat satellite is an instrument designed to detect the flux of charged particles at the satellite location. A Cesium Iodide Thallium (CsI(Tl)) crystal is used with a Kapton window to detect protons with energies greater than 1 MeV. The ground calibration of CPM was done using gamma-rays from radioactive sources and protons from particle accelerators. Based on the ground calibration results, energy deposition above 1 MeV are accepted and particle counts are recorded. It is found that CPM counts are steady and the signal for the onset and exit of South Atlantic Anomaly (SAA) region are generated in a very reliable and stable manner.
△ Less
Submitted 21 August, 2016;
originally announced August 2016.