-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Performance of the LHCb RICH detectors during LHC Run 2
Authors:
R. Calabrese,
M. Fiorini,
E. Luppi,
L. Minzoni,
I. Slazyk,
L. Tomassetti,
M. Bartolini,
R. Cardinale,
F. Fontanelli,
A. Petrolini,
A. Pistone,
M. Calvi,
C. Matteuzzi,
A. Lupato,
G. Simi,
M. Kucharczyk,
B. Malecki,
M. Witek,
S. Benson,
M. Blago,
G. Cavallero,
A. Contu,
C. D'Ambrosio,
C. Frei,
T. Gys
, et al. (57 additional authors not shown)
Abstract:
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
-
Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data
Authors:
K. S. Khaw,
M. Bartolini,
H. Binney,
R. Bjorkquist,
A. Chapelain,
A. Driutti,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
S. Ganguly,
L. K. Gibbons,
A. Gioiosa,
K. Giovanetti,
W. P. Gohn,
T. P. Gorringe,
J. B. Hempstead,
D. W. Hertzog,
M. Iacovacci,
J. Kaspar,
A. Kuchibhotla,
S. Leo,
A. Lusiani,
S. Mastroianni,
G. Pauletta
, et al. (9 additional authors not shown)
Abstract:
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS dat…
▽ More
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.
△ Less
Submitted 22 February, 2020; v1 submitted 10 May, 2019;
originally announced May 2019.
-
Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment
Authors:
A. Anastasi,
A. Basti,
F. Bedeschi,
M. Bartolini,
G. Cantatore,
D. Cauz,
G. Corradi,
S. Dabagov,
G. DI Sciascio,
R. Di Stefano,
A. Driutti,
O. Escalante,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
A. Gioiosa,
D. Hampai,
D. W. Hertzog,
M. Iacovacci,
M. Karuza,
J. Kaspar,
A. Liedl,
A. Lusiani,
F. Marignetti
, et al. (8 additional authors not shown)
Abstract:
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experi…
▽ More
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.
△ Less
Submitted 11 October, 2016;
originally announced October 2016.