-
Generation of Spatially Coherent Light at Extreme Ultraviolet Wavelengths
Authors:
Randy A. Bartels,
Ariel Paul,
Hans Green,
Henry C. Kapteyn,
Margaret M. Murnane,
Sterling Backus,
Ivan P. Christov,
Yanwei Liu,
David Attwood,
Chris Jacobsen
Abstract:
We present spatial coherence measurements of extreme-ultraviolet light generated using the process of high-harmonic upconversion of a femtosecond laser. Using a phase-matched hollow-fiber geometry, the generated beam is found to exhibit essentially full spatial coherence. The coherence of this laser-like EUV source is demonstrated by recording Gabor holograms of small objects. This work demonstrat…
▽ More
We present spatial coherence measurements of extreme-ultraviolet light generated using the process of high-harmonic upconversion of a femtosecond laser. Using a phase-matched hollow-fiber geometry, the generated beam is found to exhibit essentially full spatial coherence. The coherence of this laser-like EUV source is demonstrated by recording Gabor holograms of small objects. This work demonstrates the capability to do EUV holography using a tabletop experimental setup. Such an EUV source, with low divergence and high spatial coherence, can be used for experiments such as high-precision metrology, inspection of optical components for EUV lithography (1), and for microscopy and holography (2) with nanometer resolution. Furthermore, the short time duration of the EUV radiation (a few femtoseconds) will enable EUV microscopy and holography to be performed with ultrahigh time resolution.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
Low frequency coherent Raman imaging robust to optical scattering
Authors:
David R. Smith,
Jesse W. Wilson,
Siddarth Shivkumar,
Herve Rigneault,
Randy A. Bartels
Abstract:
We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in non-scattering specimens, such a…
▽ More
We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in non-scattering specimens, such as liquids, scattering leads to significant pump pulse contamination and prevent the extraction of a Raman spectrum. We introduce a robust method for ISRS microscopy that works in complex scattering samples. High signal-to-noise ISRS spectra are obtained even when the pump and probe pulses pass through many scattering layers.
△ Less
Submitted 10 February, 2024;
originally announced February 2024.
-
Single-Pixel Fluorescent Diffraction Tomography
Authors:
Patrick A. Stockton,
Jeffery J. Field,
Jeff Squier,
Ali Pezeshki,
Randy A. Bartels
Abstract:
Optical diffraction tomography is an indispensable tool for studying objects in three-dimensions due to its ability to accurately reconstruct scattering objects. Until now this technique has been limited to coherent light because spatial phase information is required to solve the inverse scattering problem. We introduce a method that extends optical diffraction tomography to imaging spatially inco…
▽ More
Optical diffraction tomography is an indispensable tool for studying objects in three-dimensions due to its ability to accurately reconstruct scattering objects. Until now this technique has been limited to coherent light because spatial phase information is required to solve the inverse scattering problem. We introduce a method that extends optical diffraction tomography to imaging spatially incoherent contrast mechanisms such as fluorescent emission. Our strategy mimics the coherent scattering process with two spatially coherent illumination beams. The interferometric illumination pattern encodes spatial phase in temporal variations of the fluorescent emission, thereby allowing incoherent fluorescent emission to mimic the behavior of coherent illumination. The temporal variations permit recovery of the propagation phase, and thus the spatial distribution of incoherent fluorescent emission can be recovered with an inverse scattering model.
△ Less
Submitted 5 August, 2020;
originally announced August 2020.
-
Line-scan Compressive Raman imaging with spatio-spectral encoding
Authors:
Camille Scotté,
Siddharth Sivankutty,
Randy A. Bartels,
Hervé Rigneault
Abstract:
We report a line-scanning imaging modality of Compressive Raman technology with a single-pixel detector. The spatial information along the illumination line is encoded onto one axis of a digital micromirror device, while spectral coding masks are applied along the orthogonal direction. We demonstrate imaging and classification of three different chemical species.
We report a line-scanning imaging modality of Compressive Raman technology with a single-pixel detector. The spatial information along the illumination line is encoded onto one axis of a digital micromirror device, while spectral coding masks are applied along the orthogonal direction. We demonstrate imaging and classification of three different chemical species.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
Ultrasensitive Doppler Raman spectroscopy using radio frequency phase shift detection
Authors:
David R. Smith,
Jeffrey J. Field,
David G. Winters,
Scott Domingue,
Frauke Rininsland,
Daniel J. Kane,
Jesse W. Wilson,
Randy A. Bartels
Abstract:
We introduce the first method to enable an optical amplification of a coherent Raman spectroscopy signal called radio frequency Doppler Raman spectroscopy. Doppler Raman measurements amplify the optical signals in coherent Raman spectroscopy by converting a spectral frequency shift imparted by an impulsive coherent Raman excitation to a change in a probe pulse transit time. This transit time pertu…
▽ More
We introduce the first method to enable an optical amplification of a coherent Raman spectroscopy signal called radio frequency Doppler Raman spectroscopy. Doppler Raman measurements amplify the optical signals in coherent Raman spectroscopy by converting a spectral frequency shift imparted by an impulsive coherent Raman excitation to a change in a probe pulse transit time. This transit time perturbation is detected through the phase of a radio frequency electronic signal measured at a harmonic of the probe pulse train. By exploiting this new capability to scale the signal of a coherent Raman spectroscopic signal, we open the potential to detect very weak Raman spectroscopy signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen.
△ Less
Submitted 9 December, 2019;
originally announced December 2019.
-
Compressive Raman imaging with spatial frequency modulated illumination
Authors:
Camille Scotté,
Siddharth Sivankutty,
Patrick Stockton,
Randy A. Bartels,
Hervé Rigneault
Abstract:
We report a line scanning imaging modality of compressive Raman technology with spatial frequency modulated illumination using a single pixel detector. We demonstrate the imaging and classification of three different chemical species at line scan rates of 40 Hz.
We report a line scanning imaging modality of compressive Raman technology with spatial frequency modulated illumination using a single pixel detector. We demonstrate the imaging and classification of three different chemical species at line scan rates of 40 Hz.
△ Less
Submitted 11 April, 2019; v1 submitted 21 January, 2019;
originally announced January 2019.
-
Super-resolved multimodal multiphoton microscopy with spatial frequency-modulated imaging
Authors:
Jeffrey J. Field,
Keith W. Wernsing,
Scott R. Domingue,
Alyssa M. Allende Motz,
Keith F. DeLuca,
Jennifer G. DeLuca,
Darius Kuciauskas,
Dean H. Levi,
Jeff A. Squier,
Randy A. Bartels
Abstract:
Super-resolved far-field microscopy has emerged as a powerful tool for investigating the structure of objects with resolution well below the diffraction limit of light. Nearly all super-resolution imaging techniques reported to date rely on real energy states of probe molecules to circumvent the diffraction limit, preventing super-resolved imaging of contrast mechanisms that occur via virtual ener…
▽ More
Super-resolved far-field microscopy has emerged as a powerful tool for investigating the structure of objects with resolution well below the diffraction limit of light. Nearly all super-resolution imaging techniques reported to date rely on real energy states of probe molecules to circumvent the diffraction limit, preventing super-resolved imaging of contrast mechanisms that occur via virtual energy states such as harmonic generation (HG). Here we report a super-resolution technique based on SPatIal Frequency modulated Imaging (SPIFI) that permits super-resolved nonlinear microscopy with any contrast mechanism, and with single-pixel detection. We show multimodal super-resolved images with two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG) from biological and inorganic media. Multiphoton SPIFI (MP-SPIFI) provides spatial resolution up to 2$η$ below the diffraction limit, where $η$ is the highest power of the nonlinear intensity response. MP-SPIFI has the potential to not only provide enhanced resolution in optically thin media, but shows promise for providing super-resolved imaging at depth in scattering media - opening the possibility of $\textit{in vivo}$ super-resolved imaging.
△ Less
Submitted 14 August, 2015;
originally announced August 2015.
-
A plane wave analysis of coherent holographic image reconstruction by phase transfer
Authors:
Jeffrey J. Field,
David G. Winters,
Randy A. Bartels
Abstract:
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a non-imaging single-element detector. While non-imaging fluorescence detection offers some measu…
▽ More
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a non-imaging single-element detector. While non-imaging fluorescence detection offers some measure of scattering robustness, the rate at which dynamic specimens can be imaged is severely limited. Other fluorescent imaging techniques utilize imaging detection to enhance collection rates. A notable example is light-sheet fluorescence microscopy, also known as selective-plane illumination microscopy (SPIM), which illuminates a large region within the specimen and collects emitted fluorescent light at an angle either perpendicular or oblique to the illumination light sheet. Unfortunately, scattering of the emitted fluorescent light can cause blurring of the collected images in highly turbid biological media. We recently introduced an imaging technique called coherent holographic image reconstruction by phase transfer (CHIRPT) that combines light-sheet-like illumination with non-imaging fluorescent light detection. By combining the speed of light-sheet illumination with the scattering robustness of non-imaging detection, CHIRPT is poised to have a dramatic impact on biological imaging, particularly for $\textit{in vivo}$ preparations. Here we present the mathematical formalism for CHIRPT imaging under spatially coherent illumination and present experimental data that verifies the theoretical model.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Phase-sensitive fluorescent imaging with coherent reconstruction
Authors:
Jeffrey J. Field,
David G. Winters,
Randy A. Bartels
Abstract:
Optical imaging plays a critical role in advancing our understanding of three dimensional dynamics of biological systems. Coherent imaging (CI) methods exploit spatial phase information, encoded through propagation of coherent signal light emerging from a specimen, to extract a three-dimensional representation of the object from a single high-speed measurement. Until now, CI methods could not be a…
▽ More
Optical imaging plays a critical role in advancing our understanding of three dimensional dynamics of biological systems. Coherent imaging (CI) methods exploit spatial phase information, encoded through propagation of coherent signal light emerging from a specimen, to extract a three-dimensional representation of the object from a single high-speed measurement. Until now, CI methods could not be applied to incoherent light, severely limiting their ability to image the most powerful biological probes available - fluorescent molecules - with sufficient speed and volume to observe important processes, such as neural processing in live specimens. We introduce a new imaging technique that transfers the spatial propagation phase of coherent illumination light to incoherent fluorescent light emission. The transfer of propagation phase allows CI techniques to be applied to fluorescent light imaging, and leads to large increases in imaging speed and depth of field. With this advance, biological imaging of fluorescent molecules is significantly expanded.
△ Less
Submitted 22 July, 2015;
originally announced July 2015.