-
Design, Construction, and Performance of the GEM based Radial Time Projection Chamber for the BONuS12 Experiment with CLAS12
Authors:
I. Albayrak,
S. Aune,
C. Ayerbe Gayoso,
P. Baron,
S. Bültmann,
G. Charles,
M. E. Christy,
G. Dodge,
N. Dzbenski,
R. Dupré,
K. Griffioen,
M. Hattawy,
Y. C. Hung,
N. Kalantarians,
S. Kuhn,
I. Mandjavidze,
A. Nadeeshani,
M. Ouillon,
P. Pandey,
D. Payette,
M. Pokhrel,
J. Poudel,
A. S. Tadepalli,
M. Vandenbroucke
Abstract:
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1\% dead area. P…
▽ More
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1\% dead area. Particular attention had been paid to producing excellent geometric uniformity of all electrodes, including the very thin metalized polyester film of the cylindrical cathode. This manuscript describes the design, construction, and performance of this new detector.
△ Less
Submitted 2 February, 2024;
originally announced February 2024.
-
Medica-Plus: a Micromegas-based proof-of-concept detector for sub-becquerel tritium activity assessment at the service of oncological research
Authors:
F. Jambon,
S. Aune,
P. Baron,
T. Benoit,
T. Bey,
D. Desforge,
E. Ferrer-Ribas,
A. Grabas,
M. Kebbiri,
I. Mandjavidze,
T. Papaevangelou,
M. Riallot,
M. Vandenbroucke,
F. Beau,
V. Dive,
C. Malgorn,
F. Malloggi,
A. Rousselot,
F. Carrel,
M. Trocmé
Abstract:
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
△ Less
Submitted 20 September, 2021;
originally announced September 2021.
-
Fully Bayesian Unfolding with Regularization
Authors:
Petr Baron
Abstract:
Fully Bayesian Unfolding differs from other unfolding methods by providing the full posterior probability of unfolded spectra for each bin. We extended the method for the feature of regularization which could be helpful for unfolding non-smooth, over-binned or generally non-standard shaped spectra. To decrease the computation time, the iteration process is presented.
Fully Bayesian Unfolding differs from other unfolding methods by providing the full posterior probability of unfolded spectra for each bin. We extended the method for the feature of regularization which could be helpful for unfolding non-smooth, over-binned or generally non-standard shaped spectra. To decrease the computation time, the iteration process is presented.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
A new gas-based proton-recoil telescope for quasi-absolute neutron flux measurements between 0.2 and 2 MeV neutron energy
Authors:
P. Marini,
L. Mathieu,
M. Aïche,
J. -L. Pedroza,
T. Chiron,
P. Baron,
S. Czajkowski,
F. Druillole,
P. Hellmuth,
B. Jurado,
A. Rebii,
I. Tsekhanovich
Abstract:
Absolute measurements of neutron flux are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. A new gaseous detector has been developed for measurements of 0.2 to 2 MeV neutron flux based on proton-recoil process. The detector, consisting of two segmented ionization chambers read by Micromegas technology, has b…
▽ More
Absolute measurements of neutron flux are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. A new gaseous detector has been developed for measurements of 0.2 to 2 MeV neutron flux based on proton-recoil process. The detector, consisting of two segmented ionization chambers read by Micromegas technology, has beed conceived to provide quasi-absolute neutron flux measurements with an accuracy of \simeq3%. The gas pressure flexibility makes the telescope non sensitive to γ and electrons background, and therefore advantageous over semi-conductor materials as a neutron flux instrument. The adjustable gas pressure and H-sample thickness, the use of Micromegas technology and the tracking capabilities allows the detection of neutrons on a large dynamical range and down to 200 keV with a good rejection of scattered neutron events and random background
△ Less
Submitted 18 January, 2019;
originally announced January 2019.
-
Performance measurement of HARPO: a Time Projection Chamber as a gamma-ray telescope and polarimeter
Authors:
P. Gros,
S. Amano,
D. Attié,
P. Baron,
D. Baudin,
D. Bernard,
P. Bruel,
D. Calvet,
P. Colas,
S. Daté,
A. Delbart,
M. Frotin,
Y. Geerebaert,
B. Giebels,
D. Götz,
S. Hashimoto,
D. Horan,
T. Kotaka,
M. Louzir,
F. Magniette,
Y. Minamiyama,
S. Miyamoto,
H. Ohkuma,
P. Poilleux,
I. Semeniouk
, et al. (5 additional authors not shown)
Abstract:
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices…
▽ More
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices and pseudo-tracks exiting from them are identified.
We study the various contributions to the single-photon angular resolution using Monte Carlo simulations and compare them with the experimental data and find that they are in excellent agreement. The distribution of the azimutal angle of pair conversions shows a bias due to the non-cylindrical-symmetric structure of the detector. This bias would average out for a long duration exposure on a space mission, but for this pencil-beam characterisation we have ensured its accurate simulation by a double systematics control scheme, data taking with the detector rotated at several angles with respect to the beam polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV energy range is critical for cosmic sources as their spectra are power laws which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy beyond the MeV energy regime.
△ Less
Submitted 30 August, 2017; v1 submitted 20 June, 2017;
originally announced June 2017.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.