-
The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters
Authors:
G. Aad,
A. V. Akimov,
K. Al Khoury,
M. Aleksa,
T. Andeen,
C. Anelli,
N. Aranzabal,
C. Armijo,
A. Bagulia,
J. Ban,
T. Barillari,
F. Bellachia,
M. Benoit,
F. Bernon,
A. Berthold,
H. Bervas,
D. Besin,
A. Betti,
Y. Bianga,
M. Biaut,
D. Boline,
J. Boudreau,
T. Bouedo,
N. Braam,
M. Cano Bret
, et al. (173 additional authors not shown)
Abstract:
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Cons…
▽ More
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. This paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.
△ Less
Submitted 16 May, 2022; v1 submitted 15 February, 2022;
originally announced February 2022.
-
Agent-based Simulation Model and Deep Learning Techniques to Evaluate and Predict Transportation Trends around COVID-19
Authors:
Ding Wang,
Fan Zuo,
**gqin Gao,
Yueshuai He,
Zilin Bian,
Suzana Duran Bernardes,
Chaekuk Na,
**gxing Wang,
John Petinos,
Kaan Ozbay,
Joseph Y. J. Chow,
Shri Iyer,
Hani Nassif,
Xuegang Jeff Ban
Abstract:
The COVID-19 pandemic has affected travel behaviors and transportation system operations, and cities are grappling with what policies can be effective for a phased reopening shaped by social distancing. This edition of the white paper updates travel trends and highlights an agent-based simulation model's results to predict the impact of proposed phased reopening strategies. It also introduces a re…
▽ More
The COVID-19 pandemic has affected travel behaviors and transportation system operations, and cities are grappling with what policies can be effective for a phased reopening shaped by social distancing. This edition of the white paper updates travel trends and highlights an agent-based simulation model's results to predict the impact of proposed phased reopening strategies. It also introduces a real-time video processing method to measure social distancing through cameras on city streets.
△ Less
Submitted 23 September, 2020;
originally announced October 2020.
-
Performance and Quality Control of a Radiation-Hard 12-bit 40 MSPS ADC for the ATLAS Liquid Argon Calorimeter Trigger Readout Electronics Phase-I Upgrade at the LHC
Authors:
T. Andeen,
J. Ban,
G. Brooijmans,
A. Emerman,
P. Kinget,
J. Kuppambatti,
D. Mahon,
I. Ochoa,
W. Sippach,
Q. Wang
Abstract:
A radiation-hard quad-channel 12-bit 40 MSPS pipeline analog-to-digital converter (ADC) has been designed for the trigger readout electronics Phase-I upgrade of the ATLAS Liquid Argon calorimeter, at the CERN Large Hadron Collider. The final version of the custom design, fabricated in a commercial 130 nm CMOS process, is presented and found to meet the system requirements for analog performance an…
▽ More
A radiation-hard quad-channel 12-bit 40 MSPS pipeline analog-to-digital converter (ADC) has been designed for the trigger readout electronics Phase-I upgrade of the ATLAS Liquid Argon calorimeter, at the CERN Large Hadron Collider. The final version of the custom design, fabricated in a commercial 130 nm CMOS process, is presented and found to meet the system requirements for analog performance and radiation tolerance. The procedure for quality control of 17200 ADCs is described and the results are presented.
△ Less
Submitted 6 March, 2020; v1 submitted 12 December, 2019;
originally announced December 2019.
-
A radiation-hard dual-channel 12-bit 40 MS/s ADC prototype for the ATLAS liquid argon calorimeter readout electronics upgrade at the CERN LHC
Authors:
Jayanth Kuppambatti,
Jaroslav Ban,
Timothy Andeen,
Rex Brown,
Ryne Carbone,
Peter Kinget,
Gustaaf Brooilmans,
William Sippach
Abstract:
The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The design consists of two pipeline A/D channels each with four Multiplying Digital-to-Analog Converters followed by 8-bit Successive-Approximation-Register analog-…
▽ More
The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The design consists of two pipeline A/D channels each with four Multiplying Digital-to-Analog Converters followed by 8-bit Successive-Approximation-Register analog-to-digital converters. The custom design, fabricated in a commercial 130 nm CMOS process, shows a performance of 67.9 dB SNDR at 10 MHz for a single channel at 40 MS/s, with a latency of 87.5 ns (to first bit read out), while its total power consumption is 50 mW/channel. The chip uses two power supply voltages: 1.2 and 2.5 V. The sensitivity to single event effects during irradiation is measured and determined to meet the system requirements.
△ Less
Submitted 5 June, 2017;
originally announced June 2017.
-
A Radiation-Hard Dual Channel 4-bit Pipeline for a 12-bit 40 MS/s ADC Prototype with extended Dynamic Range for the ATLAS Liquid Argon Calorimeter Readout Electronics Upgrade at the CERN LHC
Authors:
Jayanth Kuppambatti,
Jaroslav Ban,
Timothy Andeen,
Peter Kinget,
Gustaaf Brooijmans
Abstract:
The design of a radiation-hard dual channel 12-bit 40 MS/s pipeline ADC with extended dynamic range is presented, for use in the readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider. The design consists of two pipeline A/D channels with four Multiplying Digital-to-Analog Converters with nominal 12-bit resolution each. The design, fabricated in the I…
▽ More
The design of a radiation-hard dual channel 12-bit 40 MS/s pipeline ADC with extended dynamic range is presented, for use in the readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider. The design consists of two pipeline A/D channels with four Multiplying Digital-to-Analog Converters with nominal 12-bit resolution each. The design, fabricated in the IBM 130 nm CMOS process, shows a performance of 68 dB SNDR at 18 MHz for a single channel at 40 MS/s while consuming 55 mW/channel from a 2.5 V supply, and exhibits no performance degradation after irradiation. Various gain selection algorithms to achieve the extended dynamic range are implemented and tested.
△ Less
Submitted 31 July, 2013;
originally announced August 2013.
-
A Prototype PCI-based Data Acquisition System for Cosmic Ray Detection Below 10^18 eV
Authors:
S. BenZvi,
S. Westerhoff,
J. Ban,
W. Sippach
Abstract:
A prototype flash analog-to-digital readout system for cosmic ray detection at energies below 10^18 eV has been designed and tested at Columbia University Nevis Laboratories. The electronics consist of an FADC module that digitizes 16 photomultipliers at 40 MHz with 14-bit dynamic range. The module is read out to a PC (running Linux) through a PCI interface. Taking advantage of the large bandwid…
▽ More
A prototype flash analog-to-digital readout system for cosmic ray detection at energies below 10^18 eV has been designed and tested at Columbia University Nevis Laboratories. The electronics consist of an FADC module that digitizes 16 photomultipliers at 40 MHz with 14-bit dynamic range. The module is read out to a PC (running Linux) through a PCI interface. Taking advantage of the large bandwidth provided by the PCI bus, we have implemented a software-based data acquisition system. This note describes the software and electronics, as well as preliminary tests carried out using a prototype FADC module.
△ Less
Submitted 27 March, 2006;
originally announced March 2006.