-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
D retention and material defects probed using Raman microscopy in JET limiter samples and beryllium-based synthesized samples
Authors:
C Pardanaud,
M Kumar,
P Roubin,
C Martin,
Y Ferro,
J Denis,
A Widdowson,
D Douai,
M Baldwin,
A Založnik,
C Lungu,
C Porosnicu,
P Dinca,
T Dittmar,
A Hakola
Abstract:
We report on the detection by means of Raman spectroscopy of amorphous beryllium deuteride, BeD 2 , in magnetron sputtered deposits synthesized in two different laboratories and containing about 20 at.% of deuterium. In contrast, this signature has not been found for the JET limiter samples studied coming from the inner, outer or upper limiters, even when coming from a deposition zone of the limit…
▽ More
We report on the detection by means of Raman spectroscopy of amorphous beryllium deuteride, BeD 2 , in magnetron sputtered deposits synthesized in two different laboratories and containing about 20 at.% of deuterium. In contrast, this signature has not been found for the JET limiter samples studied coming from the inner, outer or upper limiters, even when coming from a deposition zone of the limiters. We give a way to disentangle that BeD 2 signature from other signatures falling in the same spectroscopic range and mainly related to other phenomena. We also analyze the Raman characteristics of the JET sample defects. These results could help in the interpretation of D thermal desorption spectra and in future analyses of JET thick Be deposit divertor tiles.
△ Less
Submitted 30 September, 2021;
originally announced September 2021.
-
An apparatus for nondestructive and rapid comparison of mask approaches in defense against infected respiratory aerosols
Authors:
Donal Sheets,
Jamie Shaw,
Michael Baldwin,
David Daggett,
Ibrahim Elali,
Erin Curry,
Ilya Sochnikov,
Jason N. Hancock
Abstract:
At the front lines of the world's response to the COVID-19 pandemic are hero-clinicians facing a lack of critical supplies including protective medical grade breathing masks and filtering materials. At the same time, the general public is now being advised to wear masks to help stop the spread. As a result, in the absence of centrally coordinated production and distribution efforts, supply chains…
▽ More
At the front lines of the world's response to the COVID-19 pandemic are hero-clinicians facing a lack of critical supplies including protective medical grade breathing masks and filtering materials. At the same time, the general public is now being advised to wear masks to help stop the spread. As a result, in the absence of centrally coordinated production and distribution efforts, supply chains for masks, respirators, and materials for advanced filtration technology are immensely burdened. Here we describe experimental efforts to nondestructively quantify three vital characteristics of mask approaches: breathability, material filtration effectiveness, and sensitivity to fit. We focus on protection against water aerosols $>$0.3$μ$m using off-the-shelf particulate, flow, and pressure sensors, permitting rapid comparative evaluation of these three properties. We present and discuss both the pressure drop and the particle transmission as a function of flow to permit comparison of relative protection for a set of proposed filter and mask designs. The design considerations of the testing apparatus can be reproduced by university laboratories and medical facilities and used for rapid local quality control of respirator masks which are of uncertified origin, monitoring the long-term effects of various disinfection schemes, and evaluating improvised products not designed or marketed for filtration.
△ Less
Submitted 3 June, 2020;
originally announced June 2020.