-
Laser Driven Nuclear physics at ELINP
Authors:
F. Negoita,
M. Roth,
P. G. Thirolf,
S. Tudisco,
F. Hannachi,
S. Moustaizis,
I. Pomerantz,
P. Mckenna,
J. Fuchs,
K. Sphor,
G. Acbas,
A. Anzalone,
P. Audebert,
S. Balascuta,
F. Cappuzzello,
M. O. Cernaianu,
S. Chen,
I. Dancus,
R. Freeman,
H. Geissel,
P. Ghenuche,
L. Gizzi,
F. Gobet,
G. Gosselin,
M. Gugiu
, et al. (31 additional authors not shown)
Abstract:
High power lasers have proven being capable to produce high energy gamma rays, charged particles and neutrons to induce all kinds of nuclear reactions. At ELI, the studies with high power lasers will enter for the first time into new domains of power and intensities.
High power lasers have proven being capable to produce high energy gamma rays, charged particles and neutrons to induce all kinds of nuclear reactions. At ELI, the studies with high power lasers will enter for the first time into new domains of power and intensities.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized $^{3}$He neutron spin-filter
Authors:
M. M. Musgrave,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
D. Blyth,
J. D. Bowman,
T. E. Chupp,
V. Cianciolo,
C. Crawford,
K. Craycraft,
N. Fomin,
J. Fry,
M. Gericke,
R. C. Gillis,
K. Grammer,
G. L. Greene,
J. Hamblen,
C. Hayes,
P. Huffman,
C. Jiang,
S. Kucuker,
M. McCrea,
P. E. Mueller,
S. I. Penttila,
W. M. Snow
, et al. (4 additional authors not shown)
Abstract:
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per seco…
▽ More
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per second per cm$^2$ and a cross sectional area of 10$\times$12~cm$^2$. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized $^{3}$He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the $^{3}$He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating $γ$-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.
△ Less
Submitted 3 April, 2018; v1 submitted 26 March, 2018;
originally announced March 2018.
-
Transmission of High-Power Electron Beams Through Small Apertures
Authors:
C. Tschalaer,
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
G. P. Williams,
S. Zhang,
.
Abstract:
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
△ Less
Submitted 31 May, 2013;
originally announced May 2013.
-
Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
W. J. Kossler,
R. Legg,
E. Long,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery…
▽ More
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.
△ Less
Submitted 30 May, 2013;
originally announced May 2013.
-
Transmission of Megawatt Relativistic Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performe…
▽ More
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performed using the 100 MeV, 430 kWatt CW electron beam from the energy recovery linac at the Jefferson Laboratory's Free Electron Laser facility as it traversed a set of small apertures in a 127 mm long aluminum block. Thermal measurements of the block together with neutron measurements near the beam-target interaction point yielded a consistent understanding of the beam losses. These were determined to be 3 ppm through a 2 mm diameter aperture and were maintained during a 7 hour continuous run.
△ Less
Submitted 1 May, 2013;
originally announced May 2013.