-
Crack-free high composition (>35%) thick (>30 nm) barrier AlGaN/AlN/GaN HEMT on sapphire with record low sheet resistance
Authors:
Swarnav Mukhopadhyay,
Cheng Liu,
Jiahao Chen,
Surjava Sanyal,
Ruixin Bai,
Guangying Wang,
Chirag Gupta,
Shubhra Pasayat
Abstract:
In this article, high composition (>35%) thick (>30 nm) barrier AlGaN/AlN/GaN HEMT structure grown on a sapphire substrate with ultra-low sheet resistivity (<250 Ω/ \Box ) is reported. Optimization of growth conditions, such as reduced growth rate, low carbon incorporation, and thickness optimization of different epitaxial layers allowed to grow a crack-free high composition and thick AlGaN barrie…
▽ More
In this article, high composition (>35%) thick (>30 nm) barrier AlGaN/AlN/GaN HEMT structure grown on a sapphire substrate with ultra-low sheet resistivity (<250 Ω/ \Box ) is reported. Optimization of growth conditions, such as reduced growth rate, low carbon incorporation, and thickness optimization of different epitaxial layers allowed to grow a crack-free high composition and thick AlGaN barrier layer HEMT structure. A significantly high two-dimensional electron gas (2DEG) density of 1.46 \times 10^{13} cm^{-2} with a room temperature mobility of 1710 cm^{2}/V.s is obtained by Hall measurement using the Van-Der-Pauw method. These state-of-the-art results show great potential for high-power Ga-polar HEMT design on the sapphire substrate.
△ Less
Submitted 11 April, 2023;
originally announced April 2023.
-
Scaling NbTiN-based ac-powered Josephson digital to 400M devices/cm$^2$
Authors:
Anna Herr,
Quentin Herr,
Steve Brebels,
Min-Soo Kim,
Ankit Pokhrel,
Blake Hodges,
Trent Josephsen,
Sabine ONeal,
Ruiheng Bai,
Katja Nowack,
Anne-Marie Valente-Feliciano,
Zsolt Tökei
Abstract:
We describe a fabrication stackup for digital logic with 16 superconducting NbTiN layers, self-shunted a-silicon barrier Josephson Junctions (JJs), and low loss, high-$κ$ tunable HZO capacitors. The stack enables 400 MJJ/cm$^2$ device density, efficient routing, and AC power distribution on a resonant network. The materials scale beyond 28nm lithography and are compatible with standard high-temper…
▽ More
We describe a fabrication stackup for digital logic with 16 superconducting NbTiN layers, self-shunted a-silicon barrier Josephson Junctions (JJs), and low loss, high-$κ$ tunable HZO capacitors. The stack enables 400 MJJ/cm$^2$ device density, efficient routing, and AC power distribution on a resonant network. The materials scale beyond 28nm lithography and are compatible with standard high-temperature CMOS processes. We report initial results for two-metal layer NbTiN wires with 50nm critical dimension. A semi-ascendance wire-and-via process module using 193i lithography and 50nm critical dimension has shown cross-section uniformity of 1%=1s across the 300mm wafer, critical temperature of 12.5K, and critical current of 0.1mA at 4.2K. We also present a new design of the resonant AC power network enabled by NbTiN wires and HZO MIM capacitors. The design matches the device density and provides a 30 GHz clock with estimated efficiency of up to 90%. Finally, magnetic imaging of patterned NbTiN ground planes shows low intrinsic defectivity and consistent trap** of vorteces in 0.5 mm holes spaced on a 20 $μ$m x 20 $μ$m grid.
△ Less
Submitted 29 April, 2023; v1 submitted 29 March, 2023;
originally announced March 2023.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike,
Jeff F Dunn
, et al. (31 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contras…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage is direct comparison with histological data as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging, but ultimately affect what questions can be answered using the data. This work represents 'Part 2' of a series of recommendations and considerations for preclinical dMRI, where we focus on best practices for dMRI of ex vivo tissue. We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We then give guidelines for ex vivo protocols, including tissue preparation, imaging sequences and data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available ex vivo dMRI datasets and dedicated software packages. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist, and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 7 February, 2023; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, anal…
▽ More
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. This work aims to serve as a reference, presenting selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. In each section, we also highlight areas for which no guidelines exist (and why), and where future work should focus. We first describe the value that small animal imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss how they are appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, imaging sequences and data processing, including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 April, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Field free switching through bulk spin-orbit torque in L10-FePt films deposited on vicinal substrates
Authors:
Yongming Luo,
Yanshan Zhuang,
Zhongshu Feng,
Haodong Fan,
Birui Wu,
Menghao **g,
Ziji Shao,
Hai Li,
Ru Bai,
Yizheng Wu,
Ningning Wang,
Tiejun Zhou
Abstract:
L10-FePt distinguishes itself for its ultrahigh perpendicular magnetic anisotropy (PMA), which enables memory cells with sufficient thermal stability to scale down to 3 nm. The recently discovered "bulk" spin-orbit torques in L10-FePt provide an efficient and scalable way to manipulate the L10-FePt magnetization. However, the existence of external field during the switching limits its practical ap…
▽ More
L10-FePt distinguishes itself for its ultrahigh perpendicular magnetic anisotropy (PMA), which enables memory cells with sufficient thermal stability to scale down to 3 nm. The recently discovered "bulk" spin-orbit torques in L10-FePt provide an efficient and scalable way to manipulate the L10-FePt magnetization. However, the existence of external field during the switching limits its practical application, and therefore field-free switching of the L10-FePt is in highly demand. In this manuscript, we demonstrate the field-free switching of the L10-FePt by growing it on vicinal MgO (001) substrates. This method is different from previously established strategies, as it does not need to add other functional layers or create asymmetry in the film structure. We demonstrate the field-free switching is robust and can withstand strong field disturbance up to ~1 kOe. The dependence on vicinal angle, film thickness, and growth temperature demonstrated a wide operation window for the field-free switching of the L10-FePt. We confirmed that the physical origin of the field-free switching is the vicinal surface-induced the tilted anisotropy of L10-FePt. We quantitatively characterize the spin-orbit torques in the L10-FePt films, and found the spin-orbit torques are not significantly influenced by the lattice strain from vicinal substrates. Our results extend beyond the established strategies to realize field-free switching, and potentially could be applied to other magnetic and antiferromagnetic systems.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Realization of a density-dependent Peierls phase in a synthetic, spin-orbit coupled Rydberg system
Authors:
Vincent Lienhard,
Pascal Scholl,
Sebastian Weber,
Daniel Barredo,
Sylvain de Léséleuc,
Rukmani Bai,
Nicolai Lang,
Michael Fleischhauer,
Hans Peter Büchler,
Thierry Lahaye,
Antoine Browaeys
Abstract:
We experimentally realize a Peierls phase in the hop** amplitude of excitations carried by Rydberg atoms, and observe the resulting characteristic chiral motion in a minimal setup of three sites. Our demonstration relies on the intrinsic spin-orbit coupling of the dipolar exchange interaction combined with time-reversal symmetry breaking by a homogeneous external magnetic field. Remarkably, the…
▽ More
We experimentally realize a Peierls phase in the hop** amplitude of excitations carried by Rydberg atoms, and observe the resulting characteristic chiral motion in a minimal setup of three sites. Our demonstration relies on the intrinsic spin-orbit coupling of the dipolar exchange interaction combined with time-reversal symmetry breaking by a homogeneous external magnetic field. Remarkably, the phase of the hop** amplitude between two sites strongly depends on the occupancy of the third site, thus leading to a correlated hop** associated to a density-dependent Peierls phase. We experimentally observe this density-dependent hop** and show that the excitations behave as anyonic particles with a non-trivial phase under exchange. Finally, we confirm the dependence of the Peierls phase on the geometrical arrangement of the Rydberg atoms.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
Quantum phases of tilted dipolar bosons in two-dimensional optical lattice
Authors:
Soumik Bandyopadhyay,
Rukmani Bai,
Sukla Pal,
K. Suthar,
Rejish Nath,
D. Angom
Abstract:
We consider a minimal model to describe the quantum phases of ultracold dipolar bosons in two-dimensional (2D) square optical lattices. The model is a variation of the extended Bose-Hubbard model and apt to study the quantum phases arising from the variation in the tilt angle $θ$ of the dipolar bosons. At low tilt angles $0^{\circ}\leqslantθ\apprle25^{\circ}$, the ground state of the system are ph…
▽ More
We consider a minimal model to describe the quantum phases of ultracold dipolar bosons in two-dimensional (2D) square optical lattices. The model is a variation of the extended Bose-Hubbard model and apt to study the quantum phases arising from the variation in the tilt angle $θ$ of the dipolar bosons. At low tilt angles $0^{\circ}\leqslantθ\apprle25^{\circ}$, the ground state of the system are phases with checkerboard order, which could be either checkerboard supersolid or checkerboard density wave. For high tilt angles $55^{\circ}\apprgeθ\apprge35^{\circ}$, phases with striped order of supersolid or density wave are preferred. In the intermediate domain $25^{\circ}\apprleθ\apprle35^{\circ}$ an emulsion or SF phase intervenes the transition between the checkerboard and striped phases. The attractive interaction dominates for $θ\apprge55^{\circ}$, which renders the system unstable and there is a density collapse. For our studies we use Gutzwiller mean-field theory to obtain the quantum phases and the phase boundaries. In addition, we calculate the phase boundaries between an incompressible and a compressible phase of the system by considering second order perturbation analysis of the mean-field theory. The analytical results, where applicable, are in excellent agreement with the numerical results.
△ Less
Submitted 18 June, 2019;
originally announced June 2019.
-
Bosonic quantum Hall states in single-layer two-dimensional optical lattices
Authors:
Rukmani Bai,
Soumik Bandyopadhyay,
Sukla Pal,
K. Suthar,
D. Angom
Abstract:
Quantum Hall (QH) states of 2D single layer optical lattices are examined using Bose-Hubbard model (BHM) in presence of artificial gauge field. We study the QH states of both the homogeneous and inhomogeneous systems. For the homogeneous case we use cluster Gutzwiller mean field (CGMF) theory with cluster sizes ranging from $2\times 2$ to $5\times 5$. We, then, consider the inhomogeneous case, whi…
▽ More
Quantum Hall (QH) states of 2D single layer optical lattices are examined using Bose-Hubbard model (BHM) in presence of artificial gauge field. We study the QH states of both the homogeneous and inhomogeneous systems. For the homogeneous case we use cluster Gutzwiller mean field (CGMF) theory with cluster sizes ranging from $2\times 2$ to $5\times 5$. We, then, consider the inhomogeneous case, which is relevant to experimental realization. In this case, we use CGMF and exact diagonalization (ED). The ED studies are using lattice sizes ranging from $3\times 3$ to $4\times 12$. Our results show that the geometry of the QH states are sensitive to the magnetic flux $α$ and cluster sizes. For homogeneous system, among various combinations of $1/5\leqslant α\leqslant 1/2$ and filling factor $ν$, only the QH state of $α=1/4$ with $ν=1/2$, $1$, $3/2$ and $2$ occur as ground states. For other combinations, the competing superfluid (SF) state is the ground state and QH state is metastable. For BHM with envelope potential all the QH states observed in homogeneous system exist for box potentials, but none for the harmonic potential. The QH states also persist for very shallow Gaussian envelope potential. As a possible experimental signature we study the two point correlations of the QH and SF states.
△ Less
Submitted 13 August, 2018; v1 submitted 22 February, 2018;
originally announced February 2018.
-
Condensates in double-well potential with synthetic gauge potentials and vortex seeding
Authors:
Rukmani Bai,
Arko Roy,
D. Angom,
P. Muruganandam
Abstract:
We demonstrate an enhancement in the vortex generation when artificial gauge potential is introduced to condensates confined in a double well potential. This is due to the lower energy required to create a vortex in the low condensate density region within the barrier. Furthermore, we study the transport of vortices between the two wells, and show that the traverse time for vortices is longer for…
▽ More
We demonstrate an enhancement in the vortex generation when artificial gauge potential is introduced to condensates confined in a double well potential. This is due to the lower energy required to create a vortex in the low condensate density region within the barrier. Furthermore, we study the transport of vortices between the two wells, and show that the traverse time for vortices is longer for the lower height of the well. We also show that the critical value of synthetic magnetic field to inject vortices into the bulk of the condensate is lower in the double-well potential compared to the harmonic confining potential.
△ Less
Submitted 20 July, 2018; v1 submitted 18 May, 2017;
originally announced May 2017.