-
MEG Upgrade Proposal
Authors:
A. M. Baldini,
F. Cei,
C. Cerri,
S. Dussoni,
L. Galli,
M. Grassi,
D. Nicolò,
F. Raffaelli,
F. Sergiampietri,
G. Signorelli,
F. Tenchini,
D. Bagliani,
M. De Gerone,
F. Gatti,
E. Baracchini,
Y. Fujii,
T. Iwamoto,
D. Kaneko,
T. Mori,
M. Nishimura,
W. Ootani,
R. Sawada,
Y. Uchiyama,
G. Boca,
P. W. Cattaneo
, et al. (43 additional authors not shown)
Abstract:
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to ena…
▽ More
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stop** target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.
△ Less
Submitted 4 February, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN
Authors:
M. Antonello,
D. Bagliani,
B. Baibussinov,
H. Bilokon,
F. Boffelli,
M. Bonesini,
E. Calligarich,
N. Canci,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
D. Dequal,
A. Dermenev,
R. Dolfini,
M. De Gerone,
S. Dussoni,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
G. T. Garvey,
F. Gatti,
D. Gibin
, et al. (114 additional authors not shown)
Abstract:
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectromete…
▽ More
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly complementing the physics capabilities. This experiment will offer remarkable discovery potentialities, collecting a very large number of unbiased events both in the neutrino and antineutrino channels, largely adequate to definitely settle the origin of the observed neutrino-related anomalies.
△ Less
Submitted 28 September, 2012; v1 submitted 3 August, 2012;
originally announced August 2012.
-
Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors
Authors:
M. Antonello,
D. Bagliani,
B. Baibussinov,
H. Bilokon,
F. Boffelli,
M. Bonesini,
E. Calligarich,
N. Canci,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
D. Dequal,
A. Dermenev,
R. Dolfini,
M. De Gerone,
S. Dussoni,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
G. T. Garvey,
F. Gatti,
D. Gibin
, et al. (114 additional authors not shown)
Abstract:
This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An a…
▽ More
This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.
△ Less
Submitted 29 March, 2012; v1 submitted 15 March, 2012;
originally announced March 2012.