-
Anisotropic molecular diffusion in confinement II: A model for structurally complex particles applied to transport in thin ionic liquid films
Authors:
Kevin Höllring,
Andreas Baer,
Nataša Vučemilović-Alagić,
David M. Smith,
Ana-Sunčana Smith
Abstract:
Hypothesis:Diffusion in confinement is an important fundamental problem with significant implications for applications of supported liquid phases. However, resolving the spatially dependent diffusion coefficient, parallel and perpendicular to interfaces, has been a standing issue and for objects of nanometric size, which structurally fluctuate on a similar time scale as they diffuse, no methodolog…
▽ More
Hypothesis:Diffusion in confinement is an important fundamental problem with significant implications for applications of supported liquid phases. However, resolving the spatially dependent diffusion coefficient, parallel and perpendicular to interfaces, has been a standing issue and for objects of nanometric size, which structurally fluctuate on a similar time scale as they diffuse, no methodology has been established so far. We hypothesise that the complex, coupled dynamics can be captured and analysed by using a model built on the $2$-dimensional Smoluchowski equation and systematic coarse-graining.
Methods and simulations: For large, flexible species, a universal approach is offered that does not make any assumptions about the separation of time scales between translation and other degrees of freedom. The method is validated on Molecular Dynamics simulations of bulk systems of a family of ionic liquids with increasing cation sizes where internal degrees of freedom have little to major effects.
Findings: After validation on bulk liquids, where we provide an interpretation of two diffusion constants for each species found experimentally, we clearly demonstrate the anisotropic nature of diffusion coefficients at interfaces. Spatial variations in the diffusivities relate to interface-induced structuring of the ionic liquids. Notably, the length scales in strongly confined ionic liquids vary consistently but differently at the solid-liquid and liquid-vapour interfaces.
△ Less
Submitted 26 June, 2023;
originally announced June 2023.
-
Anisotropic molecular diffusion in confinement I: Transport of small particles in potential and density gradients
Authors:
Kevin Höllring,
Andreas Baer,
Nataša Vučemilović-Alagić,
David M. Smith,
Ana-Sunčana Smith
Abstract:
Hypothesis: Diffusion in confinement is an important fundamental problem with significant implications for applications of supported liquid phases. However, resolving the spatially dependent diffusion coefficient, parallel and perpendicular to interfaces, has been a standing issue. In the vicinity of interfaces, density fluctuations as a consequence of layering locally impose statistical drift, wh…
▽ More
Hypothesis: Diffusion in confinement is an important fundamental problem with significant implications for applications of supported liquid phases. However, resolving the spatially dependent diffusion coefficient, parallel and perpendicular to interfaces, has been a standing issue. In the vicinity of interfaces, density fluctuations as a consequence of layering locally impose statistical drift, which impedes the analysis of spatially dependent diffusion coefficients even further. We hypothesise, that we can derive a model to spatially resolve interface-perpendicular diffusion coefficients based on local lifetime statistics with an extension to explicitly account for the effect of local drift using the Smoluchowski equation, that allows us to resolve anisotropic and spatially dependent diffusivity landscapes at interfaces.
Methods and simulations: An analytic relation between local crossing times in system slices and diffusivity as well as an explicit term for calculating drift-induced systematic errors is presented. The method is validated on Molecular Dynamics simulations of bulk water and applied to simulations of water in slit pores.
Findings: After validation on bulk liquids, we clearly demonstrate the anisotropic nature of diffusion coefficients at interfaces. Significant spatial variations in the diffusivities correlate with interface-induced structuring but cannot be solely attributed to the drift induced by local density fluctuations.
△ Less
Submitted 26 June, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Denaturation of Circular DNA: Supercoils and Overtwist
Authors:
Amir Bar,
Alkan Kabakçıoğlu,
David Mukamel
Abstract:
The denaturation transition of circular DNA is studied within a Poland-Scheraga type approach, generalized to account for the fact that the total linking number (LK), which measures the number of windings of one strand around the other, is conserved. In the model the LK conservation is maintained by invoking both overtwisting and writhing (supercoiling) mechanisms. This generalizes previous studie…
▽ More
The denaturation transition of circular DNA is studied within a Poland-Scheraga type approach, generalized to account for the fact that the total linking number (LK), which measures the number of windings of one strand around the other, is conserved. In the model the LK conservation is maintained by invoking both overtwisting and writhing (supercoiling) mechanisms. This generalizes previous studies which considered each mechanism separately. The phase diagram of the model is analyzed as a function of the temperature and the elastic constant $κ$ associated with the overtwisting energy for any given loop entropy exponent, $c$. As is the case where the two mechanisms apply separately, the model exhibits no denaturation transition for $c \le 2$. For $c>2$ and $κ=0$ we find that the model exhibits a first order transition. The transition becomes of higher order for any $κ>0$. We also calculate the contribution of the two mechanisms separately in maintaining the conservation of the linking number and find that it is weakly dependent on the loop exponent $c$.
△ Less
Submitted 30 July, 2012;
originally announced July 2012.
-
Denaturation of Circular DNA: Supercoil Mechanism
Authors:
Amir Bar,
Alkan Kabakçıoğlu,
David Mukamel
Abstract:
The denaturation transition which takes place in circular DNA is analyzed by extending the Poland-Scheraga model to include the winding degrees of freedom. We consider the case of a homopolymer whereby the winding number of the double stranded helix, released by a loop denaturation, is absorbed by \emph{supercoils}. We find that as in the case of linear DNA, the order of the transition is determin…
▽ More
The denaturation transition which takes place in circular DNA is analyzed by extending the Poland-Scheraga model to include the winding degrees of freedom. We consider the case of a homopolymer whereby the winding number of the double stranded helix, released by a loop denaturation, is absorbed by \emph{supercoils}. We find that as in the case of linear DNA, the order of the transition is determined by the loop exponent $c$. However the first order transition displayed by the PS model for $c>2$ in linear DNA is replaced by a continuous transition with arbitrarily high order as $c$ approaches 2, while the second-order transition found in the linear case in the regime $1<c\le2$ disappears. In addition, our analysis reveals that melting under fixed linking number is a \emph{condensation transition}, where the condensate is a macroscopic loop which appears above the critical temperature.
△ Less
Submitted 20 November, 2011; v1 submitted 27 August, 2011;
originally announced August 2011.