-
Purcell modified Doppler cooling of quantum emitters inside optical cavities
Authors:
Julian Lyne,
Nico S. Bassler,
Seong eun Park,
Guido Pupillo,
Claudiu Genes
Abstract:
Standard cavity cooling of atoms or dielectric particles is based on the action of dispersive optical forces in high-finesse cavities. We investigate here a complementary regime characterized by large cavity losses, resembling the standard Doppler cooling technique. For a single two-level emitter a modification of the cooling rate is obtained from the Purcell enhancement of spontaneous emission in…
▽ More
Standard cavity cooling of atoms or dielectric particles is based on the action of dispersive optical forces in high-finesse cavities. We investigate here a complementary regime characterized by large cavity losses, resembling the standard Doppler cooling technique. For a single two-level emitter a modification of the cooling rate is obtained from the Purcell enhancement of spontaneous emission in the large cooperativity limit. This mechanism is aimed at cooling of quantum emitters without closed transitions, which is the case for molecular systems, where the Purcell effect can mitigate the loss of population from the cooling cycle. We extend our analytical formulation to the many particle case governed by weak individual coupling but exhibiting collective strong Purcell enhancement to a cavity mode.
△ Less
Submitted 7 March, 2024; v1 submitted 7 November, 2023;
originally announced November 2023.
-
Metasurface-based hybrid optical cavities for chiral sensing
Authors:
Nico S. Bassler,
Andrea Aiello,
Kai P. Schmidt,
Claudiu Genes,
Michael Reitz
Abstract:
Quantum metasurfaces, i.e., two-dimensional subwavelength arrays of quantum emitters, can be employed as mirrors towards the design of hybrid cavities, where the optical response is given by the interplay of a cavity-confined field and the surface modes supported by the arrays. We show that, under external magnetic field control, stacked layers of quantum metasurfaces can serve as helicity-preserv…
▽ More
Quantum metasurfaces, i.e., two-dimensional subwavelength arrays of quantum emitters, can be employed as mirrors towards the design of hybrid cavities, where the optical response is given by the interplay of a cavity-confined field and the surface modes supported by the arrays. We show that, under external magnetic field control, stacked layers of quantum metasurfaces can serve as helicity-preserving cavities. These structures exhibit ultranarrow resonances and can enhance the intensity of the incoming field by orders of magnitude, while simultaneously preserving the handedness of the field circulating inside the resonator, as opposed to conventional cavities. The rapid phase shift in the cavity transmission around the resonance can be exploited for the sensitive detection of chiral scatterers passing through the cavity. We discuss possible applications of these resonators as sensors for the discrimination of chiral molecules.
△ Less
Submitted 1 June, 2023;
originally announced June 2023.
-
Precision pulse shape simulation for proton detection at the Nab experiment
Authors:
Leendert Hayen,
** Ha Choi,
Dustin Combs,
R. J. Taylor,
Stefan Baeßler,
Noah Birge,
Leah J. Broussard,
Christopher B. Crawford,
Nadia Fomin,
Michael Gericke,
Francisco Gonzalez,
Aaron Jezghani,
Nick Macsai,
Mark Makela,
David G. Mathews,
Russell Mammei,
Mark McCrea,
August Mendelsohn,
Austin Nelsen,
Grant Riley,
Tom Shelton,
Sky Sjue,
Erick Smith,
Albert R. Young,
Bryan Zeck
Abstract:
The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron $β$ decay to an anticipated precision of approximately 0.1\%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond l…
▽ More
The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron $β$ decay to an anticipated precision of approximately 0.1\%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. We present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.
△ Less
Submitted 6 December, 2022;
originally announced December 2022.
-
Particle Physics at the European Spallation Source
Authors:
H. Abele,
A. Alekou,
A. Algora,
K. Andersen,
S. Baessler,
L. Barron-Palos,
J. Barrow,
E. Baussan,
P. Bentley,
Z. Berezhiani,
Y. Bessler,
A. K. Bhattacharyya,
A. Bianchi,
J. Bijnens,
C. Blanco,
N. Blaskovic Kraljevic,
M. Blennow,
K. Bodek,
M. Bogomilov,
C. Bohm,
B. Bolling,
E. Bouquerel,
G. Brooijmans,
L. J. Broussard,
O. Buchan
, et al. (154 additional authors not shown)
Abstract:
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons…
▽ More
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).
△ Less
Submitted 30 January, 2024; v1 submitted 18 November, 2022;
originally announced November 2022.
-
Linear optical elements based on cooperative subwavelength emitter arrays
Authors:
Nico S. Bassler,
Michael Reitz,
Kai P. Schmidt,
Claudiu Genes
Abstract:
We describe applications of two-dimensional subwavelength quantum emitter arrays as efficient optical elements in the linear regime. For normally incident light, the cooperative optical response, stemming from emitter-emitter dipole exchanges, allows the control of the array's transmission, its resonance frequency, and bandwidth. Operations on fully polarized incident light, such as generic linear…
▽ More
We describe applications of two-dimensional subwavelength quantum emitter arrays as efficient optical elements in the linear regime. For normally incident light, the cooperative optical response, stemming from emitter-emitter dipole exchanges, allows the control of the array's transmission, its resonance frequency, and bandwidth. Operations on fully polarized incident light, such as generic linear and circular polarizers as well as phase retarders can be engineered and described in terms of Jones matrices. Our analytical approach and accompanying numerical simulations identify optimal regimes for such operations and reveal the importance of adjusting the array geometry and of the careful tuning of the external magnetic fields amplitude and direction.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Systematic and Statistical Uncertainties of the Hilbert-Transform Based High-precision FID Frequency Extraction Method
Authors:
Ran Hong,
Simon Corrodi,
Saskia Charity,
Stefan Baessler,
Jason Bono,
Timothy Chupp,
Martin Fertl,
David Flay,
Alejandro Garcia,
Jimin George,
Kevin Louis Giovanetti,
Timothy Gorringe,
Joseph Grange,
Kyun Woo Hong,
David Kawall,
Brendan Kiburg,
Bingzhi Li,
Rachel Osofsky,
Dinko Pocanic,
Suvarna Ramachandran,
Matthias Smith,
Herbert Erik Swanson,
Alec Tewsley-Booth,
Peter Winter,
Tianyu Yang
, et al. (1 additional authors not shown)
Abstract:
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation…
▽ More
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $χ^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $χ^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.
△ Less
Submitted 27 January, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
The n$^3$He Experiment: Parity Violation in Polarized Neutron Capture on $^{3}$He
Authors:
n3He Collaboration,
M. McCrea,
M. L. Kabir,
N. Birge,
C. E. Coppola,
C. Hayes,
E. Plemons,
A. Ramírez-Morales,
E. M. Scott,
J. Watts,
S. Baessler,
L. Barrón-Palos,
J. D. Bowman,
C. Britton Jr.,
J. Calarco,
V. Cianciolo,
C. B. Crawford,
D. Ezell,
N. Fomin,
I. Garishvili,
M. T. Gericke,
G. L. Greene,
G. M. Hale,
J. Hamblen,
E. Iverson
, et al. (4 additional authors not shown)
Abstract:
Significant progress has been made to experimentally determine a complete set of the parity-violating (PV) weak-interaction amplitudes between nucleons. In this paper we describe the design, construction and operation of the n$^3$He experiment that was used to measure the PV asymmetry $A_{\mathrm{PV}}$ in the direction of proton emission in the reaction…
▽ More
Significant progress has been made to experimentally determine a complete set of the parity-violating (PV) weak-interaction amplitudes between nucleons. In this paper we describe the design, construction and operation of the n$^3$He experiment that was used to measure the PV asymmetry $A_{\mathrm{PV}}$ in the direction of proton emission in the reaction $\vec{\mathrm{n}} + {^3}\mathrm{He} \rightarrow {^3}\mathrm{H} + \mathrm{p}$, using the capture of polarized cold neutrons in an unpolarized gaseous $^3\mathrm{He}$ target. This asymmetry has was recently calculated \cite{Viviani,Viviani2}, both in the traditional style meson exchange picture, and in effective field theory (EFT), including two-pion exchange. The high precision result (published separately) obtained with the experiment described herein forms an important benchmark for hadronic PV (HPV) theory in few-body systems, where precise calculations are possible. To this day, HPV is still one of the most poorly understood aspects of the electro-weak theory. The calculations estimate the size of the asymmetry to be in the range of $(-9.4 \rightarrow 3.5)\times 10^{-8}$, depending on the framework or model. The small size of the asymmetry and the small overall goal uncertainty of the experiment of $δA_{\mathrm{PV}} \simeq 1\times10^{-8}$ places strict requirements on the experiment, especially on the design of the target-detector chamber. In this paper we describe the experimental setup and the measurement methodology as well as the detailed design of the chamber, including results of Garfield++ and Geant4 simulations that form the basis of the chamber design and analysis. We also show data from commissioning and production and define the systematic errors that the chamber contributes to the measured $A_{\mathrm{PV}}$. We give the final uncertainty on the measurement.
△ Less
Submitted 22 April, 2020;
originally announced April 2020.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Design and test of a compact and high-resolution time-of-flight measurement device for cold neutron beams
Authors:
Damien Roulier,
Valery Nesvizhevsky,
Benoît Clément,
Guilhem Freche,
Guillaume Pignol,
Dominique Rebreyend,
Francis Vezzu,
Stefan Baeßler,
Alexander Strelkov
Abstract:
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with…
▽ More
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with a thin spherical conversion layer with the chopper slit in its focus. The device accepts the complete angular divergence of the initial neutron beam. The efficiency of neutron detection is constant over the detector area. Systematic corrections caused by neutron scattering in air are minimized due to the reduction of the time-of-flight length. Measurements have been performed on the beamline of the GRANIT experiment at ILL (part of the H172 beamline) on level C, and the first order diffraction peak of the crystal monochromator used for the GRANIT beamline was found to be at $λ=0.8961(11)$ nm, and having a width of $σ=0.0213(13)$ nm.
△ Less
Submitted 8 March, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized $^{3}$He neutron spin-filter
Authors:
M. M. Musgrave,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
D. Blyth,
J. D. Bowman,
T. E. Chupp,
V. Cianciolo,
C. Crawford,
K. Craycraft,
N. Fomin,
J. Fry,
M. Gericke,
R. C. Gillis,
K. Grammer,
G. L. Greene,
J. Hamblen,
C. Hayes,
P. Huffman,
C. Jiang,
S. Kucuker,
M. McCrea,
P. E. Mueller,
S. I. Penttila,
W. M. Snow
, et al. (4 additional authors not shown)
Abstract:
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per seco…
▽ More
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per second per cm$^2$ and a cross sectional area of 10$\times$12~cm$^2$. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized $^{3}$He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the $^{3}$He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating $γ$-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.
△ Less
Submitted 3 April, 2018; v1 submitted 26 March, 2018;
originally announced March 2018.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
A Storage Ring Experiment to Detect a Proton Electric Dipole Moment
Authors:
V. Anastassopoulos,
S. Andrianov,
R. Baartman,
M. Bai,
S. Baessler,
J. Benante,
M. Berz,
M. Blaskiewicz,
T. Bowcock,
K. Brown,
B. Casey,
M. Conte,
J. Crnkovic,
G. Fanourakis,
A. Fedotov,
P. Fierlinger,
W. Fischer,
M. O. Gaisser,
Y. Giomataris,
M. Grosse-Perdekamp,
G. Guidoboni,
S. Haciomeroglu,
G. Hoffstaetter,
H. Huang,
M. Incagli
, et al. (66 additional authors not shown)
Abstract:
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the…
▽ More
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Status of the GRANIT facility
Authors:
Damien Roulier,
Francis Vezzu,
Stefan Baessler,
Benoît Clément,
Daniel Morton,
Valery Nesvizhevsky,
Guillaume Pignol,
Dominique Rebreyend
Abstract:
The GRANIT facility is a follow-up project, which is motivated by the recent discovery of gravitational quantum states of ultracold neutrons. The goal of the project is to approach the ultimate accuracy in measuring parameters of such quantum states and also to apply this phenomenon and related experimental techniques to a broad range of applications in particle physics as well as in surface and n…
▽ More
The GRANIT facility is a follow-up project, which is motivated by the recent discovery of gravitational quantum states of ultracold neutrons. The goal of the project is to approach the ultimate accuracy in measuring parameters of such quantum states and also to apply this phenomenon and related experimental techniques to a broad range of applications in particle physics as well as in surface and nanoscience studies. We overview the current status of this facility, the recent test measurements and the nearest prospects.
△ Less
Submitted 6 October, 2014;
originally announced October 2014.
-
New precision measurements of free neutron beta decay with cold neutrons
Authors:
S. Baeßler,
J. D. Bowman,
S. Penttilä,
D. Počanić
Abstract:
Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the Standard Model. This paper describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and puts it into the context of other recent and planned measuremen…
▽ More
Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the Standard Model. This paper describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and puts it into the context of other recent and planned measurements of neutron beta decay observables.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
The magnetic shielding for the neutron decay spectrometer aSPECT
Authors:
Gertrud Konrad,
Fidel Ayala Guardia,
Stefan Baeßler,
Michael Borg,
Ferenc Glück,
Werner Heil,
Stefan Hiebel,
Raquel Munoz Horta,
Yury Sobolev
Abstract:
Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other ex…
▽ More
Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for aSPECT must manage with limited space. In addition, we must ensure that the additional magnetic forces on the magnet coils are not destructive. In order to determine the most suitable geometry for the magnetic shielding for aSPECT, we simulated a variety of possible geometries and combinations of shielding materials of non-linear permeability. The results of our simulations were checked through magnetic field measurements both with Hall and nuclear magnetic resonance probes. The experimental data are in good agreement with the simulated values: The mean deviation from the simulated exterior magnetic field is (-1.7+/-4.8)%. However, in the two critical regions, the internal magnetic field deviates by 0.2% respectively <1E-4 from the simulated values.
△ Less
Submitted 5 May, 2014;
originally announced May 2014.
-
Ultra-sensitive magnetometry based on free precession of nuclear spins
Authors:
C. Gemmel,
W. Heil,
K. Lenz,
Ch. Ludwig,
K. Thulley,
Yu. Sobolev,
M. Burghoff,
S. Knappe-Grueneberg,
W. Kilian,
W. Mueller,
A. Schnabel,
F. Seifert,
L. Trahms,
St. Baessler
Abstract:
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in…
▽ More
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in a new type of 3He/129Xe clock comparison experiment which should be sensitive to a sidereal variation of the relative spin precession frequency. Characteristic spin precession times T_2 of up to 60h could be measured. In combination with a signal-to-noise ratio of > 5000:1, this leads to a sensitivity level of deltaB= 1fT after an integration time of 220s and to deltaB= 10^(-4)fT after one day. Even in that sensitivity range, the magnetometer performance is statistically limited, and noise sources inherent to the magnetometer are not limiting. The reason is that free precessing 3He (129Xe) nuclear spins are almost completely decoupled from the environment. That makes this type of magnetometer in particular attractive for precision field measurements where a long-term stability is required.
△ Less
Submitted 22 May, 2009;
originally announced May 2009.
-
A method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer
Authors:
M. Kreuz,
V. V. Nesvizhevsky,
P. Schmidt-Wellenburg,
T. Soldner,
M. Thomas,
H. G. Boerner,
F. Naraghi,
G. Pignol,
K. V. Protasov,
D. Rebreyend,
F. Vezzu,
R. Flaminio,
C. Michel,
L. Pinard,
A. Remillieux,
S. Baessler,
A. M. Gagarski,
L. A. Grigorieva,
T. M. Kuzmina,
A. E. Meyerovich,
L. P. Mezhov-Deglin,
G. A. Petrov,
A. V. Strelkov,
A. Yu. Voronin
Abstract:
We present a method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer. The purpose of GRANIT is to improve the accuracy of measurement of the quantum states parameters by several orders of magnitude, taking advantage of long storage of Ultracold neutrons at specula trajectories. The transitions could be excited using a pe…
▽ More
We present a method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer. The purpose of GRANIT is to improve the accuracy of measurement of the quantum states parameters by several orders of magnitude, taking advantage of long storage of Ultracold neutrons at specula trajectories. The transitions could be excited using a periodic spatial variation of a magnetic field gradient. If the frequency of such a perturbation (in the frame of a moving neutron) coincides with a resonance frequency defined by the energy difference of two quantum states, the transition probability will sharply increase. The GRANIT experiment is motivated by searches for short-range interactions (in particular spin-dependent interactions), by studying the interaction of a quantum system with a gravitational field, by searches for extensions of the Standard model, by the unique possibility to check the equivalence principle for an object in a quantum state and by studying various quantum optics phenomena.
△ Less
Submitted 3 February, 2009; v1 submitted 1 February, 2009;
originally announced February 2009.