-
Asymmetric Electrostatic Dodecapole: Compact Bandpass Filter with Low Aberrations for Momentum Microscopy
Authors:
O. Tkach,
S. Babenkov,
Y. Lytvynenko,
O. Fedchenko,
K. Medjanik,
D. Vasilyev,
H. -J. Elmers,
G. Schönhense
Abstract:
Imaging energy filters in photoelectron microscopes and momentum microscopes employ spherical fields with deflection angles of 90°, 180° and even 2 x 180°. These instruments are optimized for high energy resolution, yet they come along with image aberrations when they are operated in high transmission mode with medium energy resolution. Here we present a new approach for bandpass-filtered imaging…
▽ More
Imaging energy filters in photoelectron microscopes and momentum microscopes employ spherical fields with deflection angles of 90°, 180° and even 2 x 180°. These instruments are optimized for high energy resolution, yet they come along with image aberrations when they are operated in high transmission mode with medium energy resolution. Here we present a new approach for bandpass-filtered imaging in real or reciprocal space, using an asymmetric electrostatic dodecapole. This multipole enables energy-dispersive beam deflection and correction of image aberrations up to the 3rd order. Owing to a deflection angle of only 4°, the total beam displacement in the filter is just ~10 mm. Hence, the entire instrument is compact and just requires a straight vacuum tube. The multipole is framed by transfer lenses in the entrance and exit branch. Two sets of 16 entrance and exit apertures with different sizes on piezomotor-driven holders allow selecting the desired resolution. The combination of apertures and dodecapole acts as a bandpass pre-selector in a high-energy time-of-flight momentum microscope at the hard X-ray beamline P22 at PETRA-III (DESY, Hamburg). At pass energies between 400 and 600 eV it transmits electrons with kinetic energies in the range of 20-40 eV and thus effectively eliminates unwanted intensity from higher-energy electrons in the ToF analyzer. At low pass energies, the instrument allows energy-filtered imaging without subsequent ToF analysis. In a laboratory experiment the 4° prototype reached < 500 meV resolution, which is sufficient for fast survey studies in the X-ray range.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Time-of-Flight Photoelectron Momentum Microscopy at 100-500 MHz Synchrotron Sources: Electron-Optical Chop** or Bandwidth Pre-Selection
Authors:
G. Schoenhense,
K. Medjanik,
O. Fedchenko,
A. Zymakova,
S. Chernov,
D. Vasilyev,
S. Babenkov,
H. J. Elmers,
P. Baumgärtel,
P. Goslawski,
G. Oehrwall,
M. Ellguth,
A. Oelsner
Abstract:
The small time gap of synchrotron radiation in conventional multi-bunch mode (100-500MHz) is prohibitive for time-of-flight (ToF) based electron spectroscopy. Even the new generation of delay-line detectors with improved time resolution (<100ps) yields only 20-100 resolved time slices within a 2-10ns gap. Here we present two techniques of implementing efficient ToF recording at sources with high r…
▽ More
The small time gap of synchrotron radiation in conventional multi-bunch mode (100-500MHz) is prohibitive for time-of-flight (ToF) based electron spectroscopy. Even the new generation of delay-line detectors with improved time resolution (<100ps) yields only 20-100 resolved time slices within a 2-10ns gap. Here we present two techniques of implementing efficient ToF recording at sources with high repetition rate. A fast electron-optical beam blanking unit with GHz bandwidth, integrated in a photoelectron momentum microscope, allows chop** the photon-pulse train to any desired repetition period. Aberration-free momentum distributions have been recorded at chopped pulse periods of 5MHz (at MAX II) and 1.25MHz (at BESSY II). The approach is benchmarked against the alternative way of implementing a dispersive element, e.g. a hemispherical analyzer, in the electron optics. Both approaches, chop** in the time domain as well as bandpass pre-selection in the energy domain, can enable efficient ToF spectroscopy, spectroscopic real-space imaging and momentum microscopy with few-meV resolution using 100-500MHz Synchrotron radiation, highly-repetitive lasers or cavity-enhanced high-harmonic sources. For comparison, we show results recorded at BESSY II with a parasitic 4-bunch island-orbit pulse train, coexisting with the 500MHz filling pattern on the main orbit.
△ Less
Submitted 1 May, 2021;
originally announced May 2021.
-
Hard X-ray Photoelectron Momentum Microscopy and Kikuchi Diffraction on (In,Ga,Mn)As Thin Films
Authors:
K. Medjanik,
O. Fedchenko,
O. Yastrubchak,
J. Sadowski,
M. Sawicki,
L. Gluba,
D. Vasilyev,
S. Babenkov,
S. Chernov,
A. Winkelmann,
H. J. Elmers,
G. Schoenhense
Abstract:
Recent advances in the brilliance of hard-X-ray beamlines and photoelectron momentum microscopy facilitate bulk valence-band map** and core-level-resolved hard-X-ray photoelectron diffraction (hXPD) for structural analysis in the same setup. High-quality MBE-grown (In,Ga,Mn)As films represent an ideal testing ground, because of the non-centrosymmetric GaAs crystal structure itself and In and Mn…
▽ More
Recent advances in the brilliance of hard-X-ray beamlines and photoelectron momentum microscopy facilitate bulk valence-band map** and core-level-resolved hard-X-ray photoelectron diffraction (hXPD) for structural analysis in the same setup. High-quality MBE-grown (In,Ga,Mn)As films represent an ideal testing ground, because of the non-centrosymmetric GaAs crystal structure itself and In and Mn do** concentrations of few percent. Here we present results of k-map** and hXPD for the title compound with 3% In and 2.5 or 5.6% Mn using hard X-ray photons (3 to 5 keV) at beamline P22 at PETRA III (DESY, Hamburg). Numerical processing (difference or ratio images) emphasizes subtle differences of hXPD patterns like the fingerprint-like hXPD-signatures of As and Ga sites. XPD calculations using the Bloch-wave method show a one-to-one correspondence with the measurements. The hXPD results reveal a predominant Ga substitutional site for Mn. Valence band map** shows that the Fermi energy lies within the valence band and decreases as the Mn concentration increases. The results support the p-d Zener model of ferromagnetism in the title compound. In addition to the shift of the Fermi energy, the band splitting increases with increasing Mn content, which we attribute to an increase of many-body correlations with increasing metallicity of the sample.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Single-Hemisphere Photoelectron Momentum Microscope With Time-of-Flight Recording
Authors:
G. Schoenhense,
S. Babenkov,
D. Vasilyev,
H. -J. Elmers,
K. Medjanik
Abstract:
Photoelectron momentum microscopy is an emerging powerful method for angle-resolved photoelectron spectroscopy (ARPES), especially in combination with imaging spin filters. These instruments record kx-ky images, typically exceeding a full Brillouin zone. As energy filters double-hemispherical or time-of-flight (ToF) devices are in use. Here we present a new approach for momentum map** of the ful…
▽ More
Photoelectron momentum microscopy is an emerging powerful method for angle-resolved photoelectron spectroscopy (ARPES), especially in combination with imaging spin filters. These instruments record kx-ky images, typically exceeding a full Brillouin zone. As energy filters double-hemispherical or time-of-flight (ToF) devices are in use. Here we present a new approach for momentum map** of the full half-space, based on a single hemispherical analyzer (path radius 225 mm). Excitation by an unfocused He lamp yielded an energy resolution of 7.7 meV. The performance is demonstrated by k-imaging of quantum-well states in Au and Xe multilayers. The alpha-square-aberration term (alpha: entrance angle in the dispersive plane) and the transit-time spread of the electrons in the spherical field are studied in a large pass-energy (6 to 660 eV) and angular range (alpha up to about 7°). It is discussed how the method circumvents the preconditions of previous theoretical work on the resolution limitation due to the alpha-square-term and the transit-time spread, being detrimental for time-resolved experiments. Thanks to k-resolved detection, both effects can be corrected numerically. We introduce a dispersive-plus-ToF hybrid mode of operation, with an imaging ToF analyzer behind the exit slit of the hemisphere. This instrument captures 3D data arrays I(EB,kx,ky), yielding a gain up to N^2 in recording efficiency (N being the number of resolved time slices). A key application will be ARPES at sources with high pulse rates like Synchrotrons with 500 MHz time structure.
△ Less
Submitted 7 August, 2020; v1 submitted 31 July, 2020;
originally announced July 2020.