-
Trigger efficiencies of a proposed beam monitoring detector (BeBe) for p+p collisions at NICA energies
Authors:
Marco Alberto Ayala-Torres,
Lucina Gabriela Espinoza Beltrán,
Luis A. Hernández-Cruz,
Luis Manuel Montaño,
Eduardo Moreno-Barbosa,
C. H. Zepeda Fernández
Abstract:
The Multipurpose Detector (MPD) consists of a typical array of sub-detectors to study the nuclear matter originating from the collisions of beams provided by the Nuclotron-based Ion Collider fAcility (NICA). A beam monitoring detector~(BeBe) is proposed for stage 2 of MPD to increase the trigger capabilities. BeBe is constituted of two plastic scintillator disks segmented in 80 cells $\pm~2~m$ awa…
▽ More
The Multipurpose Detector (MPD) consists of a typical array of sub-detectors to study the nuclear matter originating from the collisions of beams provided by the Nuclotron-based Ion Collider fAcility (NICA). A beam monitoring detector~(BeBe) is proposed for stage 2 of MPD to increase the trigger capabilities. BeBe is constituted of two plastic scintillator disks segmented in 80 cells $\pm~2~m$ away from the interaction point of MPD. Laboratory measurements to obtain the energy resolution of an individual BeBe cell prototype are presented. It is shown that an energy resolution of $22\pm6\%$ can be obtained. Based on Monte Carlo simulations, the trigger efficiencies of the BeBe are presented for p+p collisions at 11~GeV considering a threshold in the energy loss of the charged particles reaching the detector.
△ Less
Submitted 28 May, 2023;
originally announced May 2023.
-
Low-Energy Physics in Neutrino LArTPCs
Authors:
D. Caratelli,
W. Foreman,
A. Friedland,
S. Gardiner,
I. Gil-Botella,
G. Karagiorgi,
M. Kirby,
G. Lehmann Miotto,
B. R. Littlejohn,
M. Mooney,
J. Reichenbacher,
A. Sousa,
K. Scholberg,
J. Yu,
T. Yang,
S. Andringa,
J. Asaadi,
T. J. C. Bezerra,
F. Capozzi,
F. Cavanna,
E. Church,
A. Himmel,
T. Junk,
J. Klein,
I. Lepetic
, et al. (264 additional authors not shown)
Abstract:
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below…
▽ More
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon do**. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
Liquid argon characterization of the X-ARAPUCA with alpha particles, gamma rays and cosmic muons
Authors:
H. V. Souza,
E. Segreto,
A. A. Machado,
R. R. Sarmento,
M. C. Q. Bazetto,
L. Paulucci,
F. Marinho,
V. L. Pimentel,
F. L. Demolin,
G. de Souza,
A. C. Fauth,
M. A. Ayala-Torres
Abstract:
The X-ARAPUCA device is the baseline choice for the photon detection system of the first far detector module of the DUNE experiment. We present the results of the first complete characterization of a small scale X-ARAPUCA prototype, which is a slice of a full DUNE module. Its total detection efficiency in liquid argon was measured with three different ionizing radiations: $α$ particles, $γ$'s and…
▽ More
The X-ARAPUCA device is the baseline choice for the photon detection system of the first far detector module of the DUNE experiment. We present the results of the first complete characterization of a small scale X-ARAPUCA prototype, which is a slice of a full DUNE module. Its total detection efficiency in liquid argon was measured with three different ionizing radiations: $α$ particles, $γ$'s and muons and resulted to be $\sim$2.2% when the active silicon photomultipliers were biased at +5.0 V of over voltage, corresponding to a Photon Detection Efficiency around 50% at room temperature. This value comfortably satisfies the requirements of the first DUNE far detector module (detection efficiency $>$2.0%) and allows to achieve an energy resolution comparable to the one achievable with the Time Projection Chambers for energies below 10 MeV, which is the region relevant for Supernova neutrino detection.
△ Less
Submitted 6 December, 2021; v1 submitted 8 June, 2021;
originally announced June 2021.
-
Time resolution analysis of detectors based on plastic scintillators coupled to silicon photomultipliers
Authors:
Marco Alberto Ayala-Torres,
Luis Manuel Montaño Zetina,
Marcos Fontaine Sánchez
Abstract:
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained results are relevant for trigger subsystems of Multi-Purpose Detector (MPD) and Baryonic Matter at the Nuclotron (BM@N) at the NICA heavy-ion collider. The results…
▽ More
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained results are relevant for trigger subsystems of Multi-Purpose Detector (MPD) and Baryonic Matter at the Nuclotron (BM@N) at the NICA heavy-ion collider. The results show very high efficiency and good timing performance of the counters.
△ Less
Submitted 10 December, 2019;
originally announced December 2019.
-
Time resolution studies for scintillating plastics coupled to silicon photo-multipliers
Authors:
Mauricio Alvarado,
Alejandro Ayala,
Marco Alberto Ayala-Torres,
Wolfgang Bietenholz,
Isabel Dominguez,
Marcos Fontaine,
P. González-Zamora,
Luis Manuel Montaño,
E. Moreno Barbosa,
Miguel Enrique Patiño Salazar,
V. Z. Reyna Ortiz,
M. Rodríguez Cahuantzi,
G. Tejeda Muńoz,
Maria Elena Tejeda-Yeomans,
Luis Valenzuela-Cázares,
C. H. Zepeda Fernández
Abstract:
We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can be employed to provide a fast trigger signal for NICA's Multi Purpose Detector (MPD). Our results show that such a system made of cells with transverse dimensi…
▽ More
We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can be employed to provide a fast trigger signal for NICA's Multi Purpose Detector (MPD). Our results show that such a system made of cells with transverse dimensions of order of a few cm, coupled to silicon photo-multipliers, provides a time resolution of about 50 ps, which can be even further improved to attain the MPD trigger requirements of 20 ps.
△ Less
Submitted 15 January, 2019;
originally announced January 2019.
-
A beam-beam monitoring detector for the MPD experiment at NICA
Authors:
Mauricio Alvarado,
Alejandro Ayala,
Marco Alberto Ayala-Torres,
Wolfgang Bietenholz,
Isabel Dominguez,
Marcos Fontaine,
P. González-Zamora,
Luis Manuel Montaño,
E. Moreno-Barbosa,
Miguel Enrique Patiño Salazar,
L. A. P. Moreno,
P. A. Nieto-Marín,
V. Z. Reyna Ortiz,
M. Rodríguez-Cahuantzi,
G. Tejeda-Muñoz,
Maria Elena Tejeda-Yeomans,
A. Villatoro-Tello,
C. H. Zepeda Fernández
Abstract:
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evol…
▽ More
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evolution of the early Universe and the formation of neutron stars. In order to extend the MPD trigger capabilities, we propose to include a high granularity beam-beam monitoring detector (BE-BE) to provide a level-0 trigger signal with an expected time resolution of 30 ps. This new detector will improve the determination of the reaction plane by the MPD experiment, a key measurement for flow studies that provides physics insight into the early stages of the reaction. In this work, we use simulated Au+Au collisions at NICA energies to show the potential of such a detector to determine the event plane resolution, providing further redundancy to the detectors originally considered for this purpose namely, the Fast Forward Detector (FFD) and the Hadron Calorimeter (HCAL). We also show our results for the time resolution studies of two prototype cells carried out at the T10 beam line at the CERN PS complex.
△ Less
Submitted 4 December, 2019; v1 submitted 25 September, 2018;
originally announced September 2018.