Long-term Operation of the Multi-Wire-Proportional-Chambers of the LHCb Muon System
Authors:
F. P. Albicocco,
L. Anderlini,
M. Anelli,
F. Archilli,
G. Auriemma,
W. Baldini,
G. Bencivenni,
N. Bondar,
B. Bochin,
D. Brundu,
S. Cadeddu,
P. Campana,
G. Carboni,
A. Cardini,
M. Carletti,
L. Casu,
A. Chubykin,
P. Ciambrone,
E. Dané,
P. De Simone,
M. Fontana,
P. Fresch,
M. Gatta,
G. Gavrilov,
S. Gets
, et al. (33 additional authors not shown)
Abstract:
The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010 until 2018, we did not observe appreciable signs of ageing of the detector in terms of reduced performance. However, during such a long period, many chamber gas g…
▽ More
The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010 until 2018, we did not observe appreciable signs of ageing of the detector in terms of reduced performance. However, during such a long period, many chamber gas gaps suffered from HV trips. Most of the trips were due to Malter-like effects, characterised by the appearance of local self-sustained high currents, presumably originating from impurities induced during chamber production. Very effective, though long, recovery procedures were implemented with a HV training of the gaps in situ while taking data. The training allowed most of the affected chambers to be returned to their full functionality and the muon detector efficiency to be kept close to 100%. The possibility of making the recovery faster and even more effective by adding a small percentage of oxygen in the gas mixture has been studied and successfully tested.
△ Less
Submitted 20 May, 2021; v1 submitted 6 August, 2019;
originally announced August 2019.
-
Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency
Authors:
L. Anderlini,
M. Anelli,
F. Archilli,
G. Auriemma,
W. Baldini,
G. Bencivenni,
A. Bizzeti,
V. Bocci,
N. Bondar,
W. Bonivento,
B. Bochin,
C. Bozzi,
D. Brundu,
S. Cadeddu,
P. Campana,
G. Carboni,
A. Cardini,
M. Carletti,
L. Casu,
A. Chubykin,
P. Ciambrone,
E. Dané,
P. De Simone,
A. Falabella,
G. Felici
, et al. (39 additional authors not shown)
Abstract:
A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from 70 ns to 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at…
▽ More
A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from 70 ns to 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.
△ Less
Submitted 28 March, 2016; v1 submitted 28 February, 2016;
originally announced February 2016.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Performance of the LHCb muon system
Authors:
A. A. Alves Jr,
L. Anderlini,
M. Anelli,
R. Antunes Nobrega,
G. Auriemma,
W. Baldini,
G. Bencivenni,
R. Berutti,
A. Bizzeti,
V. Bocci,
N. Bondar,
W. Bonivento,
B. Botchin,
S. Cadeddu,
P. Campana,
G. Carboni,
A. Cardini,
M. Carletti,
P. Ciambrone,
E. Dané S. De Capua,
V. De Leo,
C. Deplano,
P. De Simone,
F. Dettori,
A. Falabella
, et al. (48 additional authors not shown)
Abstract:
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are comp…
▽ More
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements
△ Less
Submitted 15 February, 2013; v1 submitted 6 November, 2012;
originally announced November 2012.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
Performance of the LHCb muon system with cosmic rays
Authors:
M. Anelli,
R. AntunesNobrega,
G. Auriemma,
W. Baldini,
G. Bencivenni,
R. Berutti,
V. Bocci,
N. Bondar,
W. Bonivento,
B. Botchin,
S. Cadeddu,
P. Campana,
G. Carbonih,
A. Cardini,
M. Carletti,
P. Ciambrone,
E. Dane,
S. DeCapua,
C. Deplano,
P. DeSimone,
F. Dettori,
A. Falabella,
F. Ferreira Rodriguez,
M. Frosini,
S. Furcas
, et al. (39 additional authors not shown)
Abstract:
The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber efficiency, time resolution and cluster size are described in detail. The results are in agreement with the expected detector performance.
The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber efficiency, time resolution and cluster size are described in detail. The results are in agreement with the expected detector performance.
△ Less
Submitted 10 September, 2010;
originally announced September 2010.
-
Experimental determination of the Townsend coefficient for Argon-CO2 gas mixtures at high fields
Authors:
G. Auriemma,
D. Fidanza,
G. Pirozzi,
C. Satriano
Abstract:
The first Townsend coefficient for Ar-CO2 based gas mixtures has been measured over a wide range of reduced electric field. The experimental setup and the measurement technique are described here. A linear superposition model has also been successfully applied.
The first Townsend coefficient for Ar-CO2 based gas mixtures has been measured over a wide range of reduced electric field. The experimental setup and the measurement technique are described here. A linear superposition model has also been successfully applied.
△ Less
Submitted 15 July, 2003;
originally announced July 2003.