-
Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources
Authors:
Valerio Bellucci,
Sarlota Birnsteinova,
Tokushi Sato,
Romain Letrun,
Jayanath C. P. Koliyadu,
Chan Kim,
Gabriele Giovanetti,
Carsten Deiter,
Liubov Samoylova,
Ilia Petrov,
Luis Lopez Morillo,
Rita Graceffa,
Luigi Adriano,
Helge Huelsen,
Heiko Kollmann,
Thu Nhi Tran Calliste,
Dusan Korytar,
Zdenko Zaprazny,
Andrea Mazzolari,
Marco Romagnoni,
Eleni Myrto Asimakopoulou,
Zisheng Yao,
Yuhe Zhang,
Jozef Ulicny,
Alke Meents
, et al. (5 additional authors not shown)
Abstract:
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of indust…
▽ More
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
ForMAX -- a beamline for multiscale and multimodal structural characterization of hierarchical materials
Authors:
K. Nygård,
S. A. McDonald,
J. B. González,
V. Haghighat,
C. Appel,
E. Larsson,
R. Ghanbari,
M. Viljanen,
J. Silva,
S. Malki,
Y. Li,
V. Silva,
C. Weninger,
F. Engelmann,
T. Jeppsson,
G. Felcsuti,
T. Rosén,
K. Gordeyeva,
L. D. Söderberg,
H. Dierks,
Y. Zhang,
Z. Yao,
R. Yang,
E. M. Asimakopoulou,
J. K. Rogalinski
, et al. (13 additional authors not shown)
Abstract:
The ForMAX beamline at the MAX IV Laboratory provides multiscale and multimodal structural characterization of hierarchical materials in the nm to mm range by combining small- and wide-angle x-ray scattering with full-field microtomography. The modular design of the beamline is optimized for easy switching between different experimental modalities. The beamline has a special focus on the developme…
▽ More
The ForMAX beamline at the MAX IV Laboratory provides multiscale and multimodal structural characterization of hierarchical materials in the nm to mm range by combining small- and wide-angle x-ray scattering with full-field microtomography. The modular design of the beamline is optimized for easy switching between different experimental modalities. The beamline has a special focus on the development of novel, fibrous materials from forest resources, but it is also well suited for studies within, e.g., food science and biomedical research.
△ Less
Submitted 2 February, 2024; v1 submitted 13 December, 2023;
originally announced December 2023.
-
Development towards high-resolution kHz-speed rotation-free volumetric imaging
Authors:
Eleni Myrto Asimakopoulou,
Valerio Bellucci,
Sarlota Birnsteinova,
Zisheng Yao,
Yuhe Zhang,
Ilia Petrov,
Carsten Deiter,
Andrea Mazzolari,
Marco Romagnoni,
Dusan Korytar,
Zdenko Zaprazny,
Zuzana Kuglerova,
Libor Juha,
Bratislav Lukic,
Alexander Rack,
Liubov Samoylova,
Francisco Garcia Moreno,
Stephen A Hall,
Tillmann Neu,
Xiaoyu Liang,
Patrik Vagovic,
Pablo Villanueva-Perez
Abstract:
X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per se…
▽ More
X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 $μ$m resolution per projection using the full dynamical range of our detectors. Since XMPI is a method under development, we also provide different tests for the instrumentation of up to 3000 frames per second. As the flux of X-ray sources grows globally, XMPI is a promising technique for current and future X-ray imaging instruments.
△ Less
Submitted 7 November, 2023;
originally announced November 2023.
-
Megahertz X-ray Multi-projection imaging
Authors:
Pablo Villanueva-Perez,
Valerio Bellucci,
Yuhe Zhang,
Sarlota Birnsteinova,
Rita Graceffa,
Luigi Adriano,
Eleni Myrto Asimakopoulou,
Ilia Petrov,
Zisheng Yao,
Marco Romagnoni,
Andrea Mazzolari,
Romain Letrun,
Chan Kim,
Jayanath C. P. Koliyadu,
Carsten Deiter,
Richard Bean,
Gabriele Giovanetti,
Luca Gelisio,
Tobias Ritschel,
Adrian Mancuso,
Henry N. Chapman,
Alke Meents,
Tokushi Sato,
Patrik Vagovic
Abstract:
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz…
▽ More
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz (MHz) X-ray multi-projection imaging (MHz-XMPI), a technique capable of recording volumetric information at MHz rates and micrometer resolution without scanning the sample. We achieved this by harnessing the unique megahertz pulse structure and intensity of the European X-ray Free-electron Laser with a combination of novel detection and reconstruction approaches that do not require sample rotations. Our approach enables generating multiple X-ray probes that simultaneously record several angular projections for each pulse in the megahertz pulse burst. We provide a proof-of-concept demonstration of the MHz-XMPI technique's capability to probe 4D (3D+time) information on stochastic phenomena and non-reproducible processes three orders of magnitude faster than state-of-the-art time-resolved X-ray tomography, by generating 3D movies of binary droplet collisions. We anticipate that MHz-XMPI will enable in-situ and operando studies that were impossible before, either due to the lack of temporal resolution or because the systems were opaque (such as for MHz imaging based on optical microscopy).
△ Less
Submitted 19 May, 2023;
originally announced May 2023.
-
Ultrasound cavitation and exfoliation dynamics of 2D materials re-vealed in operando by X-ray free electron laser megahertz imaging
Authors:
Kang Xiang,
Shi Huang,
Hongyuan Song,
Vasilii Bazhenov,
Valerio Bellucci,
Sarlota Birnsteinova,
Raphael de Wijn,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Adam Round,
Ekaterina Round,
Abhisakh Sarma,
Tokushi Sato,
Marcin Sikorski,
Yuhe Zhang,
Eleni Myrto Asimakopoulou,
Pablo Villanueva-Perez,
Kyriakos Porfyrakis,
Iakovos Tzanakis,
Dmitry G. Eskin,
Nicole Grobert,
Adrian Mancuso,
Richard Bean,
Patrik Vagovic,
Jiawei Mi
Abstract:
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simul…
▽ More
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simultaneously, most theories reported to date still remain elusive. Here, using the ultra-short X-ray Free Electron Laser pulses (~25ps) with a unique pulse train structure, we applied MHz X-ray Microscopy and machine-learning technique to reveal unambiguously the full cycles of the ultrasound cavitation and graphite layer exfoliation dynamics with sub-microsecond and micrometer resolution. Cyclic fatigue shock wave impacts produced by ultrasound cloud implosion were identified as the dominant mechanism to deflect and exfoliate graphite layers mechanically. For the graphite flakes, exfoliation rate as high as ~5 angstroms per shock wave impact was observed. For the HOPG graphite, the highest exfoliation rate was ~0.15 angstroms per impact. These new findings are scientifically and technologically important for develo** industrial upscaling strategies for ultrasonic exfoliation of 2D materials.
△ Less
Submitted 23 June, 2023; v1 submitted 15 May, 2023;
originally announced May 2023.
-
Online dynamic flat-field correction for MHz Microscopy data at European XFEL
Authors:
Sarlota Birnsteinova,
Danilo E. Ferreira de Lima,
Egor Sobolev,
Henry J. Kirkwood,
Valerio Bellucci,
Richard J. Bean,
Chan Kim,
Jayanath C. P. Koliyadu,
Tokushi Sato,
Fabio Dall'Antonia,
Eleni Myrto Asimakopoulou,
Zisheng Yao,
Khachiwan Buakor,
Yuhe Zhang,
Alke Meents,
Henry N. Chapman,
Adrian P. Mancuso,
Pablo Villanueva-Perez,
Patrik Vagovic
Abstract:
The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as…
▽ More
The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as phase retrieval and modal decomposition. In addition, access to normalized projections during data acquisition can play an important role in decision-making and improve the quality of the data. However, the stochastic nature of XFEL sources hinders the use of existing flat-flied normalization methods during MHz X-ray microscopy experiments. Here, we present an online dynamic flat-field correction method based on principal component analysis of dynamically evolving flat-field images. The method is used for the normalization of individual X-ray projections and has been implemented as an online analysis tool at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of EuXFEL.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
The ABC130 barrel module prototy** programme for the ATLAS strip tracker
Authors:
Luise Poley,
Craig Sawyer,
Sagar Addepalli,
Anthony Affolder,
Bruno Allongue,
Phil Allport,
Eric Anderssen,
Francis Anghinolfi,
Jean-François Arguin,
Jan-Hendrik Arling,
Olivier Arnaez,
Nedaa Alexandra Asbah,
Joe Ashby,
Eleni Myrto Asimakopoulou,
Naim Bora Atlay,
Ludwig Bartsch,
Matthew J. Basso,
James Beacham,
Scott L. Beaupré,
Graham Beck,
Carl Beichert,
Laura Bergsten,
Jose Bernabeu,
Prajita Bhattarai,
Ingo Bloch
, et al. (224 additional authors not shown)
Abstract:
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000…
▽ More
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototy** programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-25) and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototy** program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.