-
Hybrid quantum programming with PennyLane Lightning on HPC platforms
Authors:
Ali Asadi,
Amintor Dusko,
Chae-Yeun Park,
Vincent Michaud-Rioux,
Isidor Schoch,
Shuli Shu,
Trevor Vincent,
Lee James O'Riordan
Abstract:
We introduce PennyLane's Lightning suite, a collection of high-performance state-vector simulators targeting CPU, GPU, and HPC-native architectures and workloads. Quantum applications such as QAOA, VQE, and synthetic workloads are implemented to demonstrate the supported classical computing architectures and showcase the scale of problems that can be simulated using our tooling. We benchmark the p…
▽ More
We introduce PennyLane's Lightning suite, a collection of high-performance state-vector simulators targeting CPU, GPU, and HPC-native architectures and workloads. Quantum applications such as QAOA, VQE, and synthetic workloads are implemented to demonstrate the supported classical computing architectures and showcase the scale of problems that can be simulated using our tooling. We benchmark the performance of Lightning with backends supporting CPUs, as well as NVidia and AMD GPUs, and compare the results to other commonly used high-performance simulator packages, demonstrating where Lightning's implementations give performance leads. We show improved CPU performance by employing explicit SIMD intrinsics and multi-threading, batched task-based execution across multiple GPUs, and distributed forward and gradient-based quantum circuit executions across multiple nodes. Our data shows we can comfortably simulate a variety of circuits, giving examples with up to 30 qubits on a single device or node, and up to 41 qubits using multiple nodes.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Continuously tracked, stable, large excursion trajectories of dipolar coupled nuclear spins
Authors:
Ozgur Sahin,
Hawraa Al Asadi,
Paul Schindler,
Arjun Pillai,
Erica Sanchez,
Matthew Markham,
Mark Elo,
Maxwell McAllister,
Emanuel Druga,
Christoph Fleckenstein,
Marin Bukov,
Ashok Ajoy
Abstract:
We report an experimental approach to excite, stabilize, and continuously track Bloch sphere orbits of dipolar-coupled nuclear spins in a solid. We demonstrate these results on a model system of hyperpolarized 13C nuclear spins in diamond. Without quantum control, inter-spin coupling leads to rapid spin decay in T2*=1.5ms. We elucidate a method to preserve trajectories for over T2'>27s at excursio…
▽ More
We report an experimental approach to excite, stabilize, and continuously track Bloch sphere orbits of dipolar-coupled nuclear spins in a solid. We demonstrate these results on a model system of hyperpolarized 13C nuclear spins in diamond. Without quantum control, inter-spin coupling leads to rapid spin decay in T2*=1.5ms. We elucidate a method to preserve trajectories for over T2'>27s at excursion solid angles up to 16 degrees, even in the presence of strong inter-spin coupling. This exploits a novel spin driving strategy that thermalizes the spins to a long-lived dipolar many-body state, while driving them in highly stable orbits. We show that motion of the spins can be quasi-continuously tracked for over 35s in three dimensions on the Bloch sphere. In this time the spins complete >68,000 closed precession orbits, demonstrating high stability and robustness against error. We experimentally probe the transient approach to such rigid motion, and thereby show the ability to engineer highly stable "designer" spin trajectories. Our results suggest new ways to stabilize and interrogate strongly-coupled quantum systems through periodic driving and portend powerful applications of rigid spin orbits in quantum sensing.
△ Less
Submitted 13 July, 2022; v1 submitted 29 June, 2022;
originally announced June 2022.
-
The Ion Fluorescence Chamber (IFC): A new concept for directional dark matter and topologically imaging neutrinoless double beta decay searches
Authors:
B. J. P. Jones,
F. W. Foss,
J. A. Asaadi,
E. D. Church,
J. deLeon,
E. Gramellini,
O. H. Seidel,
T. T. Vuong
Abstract:
We introduce a novel particle detection concept for large-volume, fine granularity particle detection: The Ion Fluorescence Chamber (IFC). In electronegative gases such as SF$_6$ and SeF$_6$, ionizing particles create ensembles of positive and negative ions. In the IFC, positive ions are drifted to a chemically active cathode where they react with a custom organic turn-on fluorescent monolayer enc…
▽ More
We introduce a novel particle detection concept for large-volume, fine granularity particle detection: The Ion Fluorescence Chamber (IFC). In electronegative gases such as SF$_6$ and SeF$_6$, ionizing particles create ensembles of positive and negative ions. In the IFC, positive ions are drifted to a chemically active cathode where they react with a custom organic turn-on fluorescent monolayer encoding a long-lived 2D image. The negative ions are sensed electrically with course resolution at the anode, inducing an optical microscope to travel to and scan the corresponding cathode location for the fluorescent image. This concept builds on technologies developed for barium tagging in neutrinoless double beta decay, combining the ultra-fine imaging capabilities of an emulsion detector with the monolithic sensing of a time projection chamber. The result is a high precision imaging detector over arbitrarily large volumes without the challenges of ballooning channel count or system complexity. After outlining the concept, we discuss R\&D to be undertaken to demonstrate it, and explore application to both directional dark matter searches in SF$_6$ and searches for neutrinoless double beta decay in large $^{82}$SeF$_6$ chambers.
△ Less
Submitted 18 March, 2022;
originally announced March 2022.
-
Dosimetric Comparison of Passive Scattering and Active Scanning Proton Therapy Techniques Using GATE Simulation
Authors:
A. Asadi,
A. Akhavanallaf,
S. A. Hosseini,
H. Zaidi
Abstract:
In this study, two proton beam delivery designs, passive scattering proton therapy (PSPT) and pencil beam scanning (PBS), were quantitatively compared in terms of dosimetric indices. The GATE Monte Carlo code was used to simulate the proton beam system; and the developed simulation engines were benchmarked with respect to the experimental measurements. A water phantom was used to simulate system e…
▽ More
In this study, two proton beam delivery designs, passive scattering proton therapy (PSPT) and pencil beam scanning (PBS), were quantitatively compared in terms of dosimetric indices. The GATE Monte Carlo code was used to simulate the proton beam system; and the developed simulation engines were benchmarked with respect to the experimental measurements. A water phantom was used to simulate system energy parameters using a set of depth-dose data in the energy range of 120-235 MeV. To compare the performance of PSPT against PBS, multiple dosimetric parameters including FWHM, peak position, range, peak-to-entrance dose ratio, and dose volume histogram have been analyzed under the same conditions. Furthermore, the clinical test cases introduced by AAPM TG-119 were simulated in both beam delivery modes to compare the relevant clinical values obtained from DVH analysis. The parametric comparison in the water phantom between the two techniques revealed that the value of peak-to-entrance dose ratio in PSPT is considerably higher than that from PBS by a factor of 8%. In addition, the FWHM of the lateral beam profile in PSPT was increased by a factor of 7% compared to the corresponding value obtained from PBS model. TG-119 phantom simulations showed that the difference of PTV mean dose between PBS and PSPT techniques are up to 2.9% while the difference of max dose to organ at risks (OARs) exceeds 33%. The results demonstrated that the PBS proton therapy systems was superior in adapting to the target volume, better dose painting, and lower out-of-field dose compared to PSPT design.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Development and validation of an optimal GATE model for proton pencil-beam scanning delivery
Authors:
A. Asadi,
A. Akhavanallaf,
S. A. Hosseini,
N. vosoughi,
H. Zaidi
Abstract:
Objective: To develop and validate an independent Monet Carlo dose calculation engine to support for software verification of treatment planning systems and quality assurance workflow. Method: GATE Monte Carlo toolkit was employed to simulate a fixed horizontal active scan-based proton beam delivery. Within the nozzle, two primary and secondary dose monitors have been designed allowing to compare…
▽ More
Objective: To develop and validate an independent Monet Carlo dose calculation engine to support for software verification of treatment planning systems and quality assurance workflow. Method: GATE Monte Carlo toolkit was employed to simulate a fixed horizontal active scan-based proton beam delivery. Within the nozzle, two primary and secondary dose monitors have been designed allowing to compare the accuracy of dose estimation from MC simulation with respect to physical quality assurance measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of AAPM TG-119 and a prostate patient. Result: MC simulation showed an excellent agreement with measurements in the lateral depth-dose parameters and SOBP characteristics within maximum relative error of 0.95% in range, 3.4% in entrance to peak ratio, 2.3% in mean point to point, and 0.852% in peak location. Mean relative absolute difference between MC simulation and the measurement in terms of absorbed dose in SOBP region was $0.93\% \pm 0.88\%$. Clinical phantom study showed a good agreement compared to a commercial treatment planning system (relative error for TG-119 PTV-D${}{95}$ $\mathrm{\sim}$ 1.8%; and for prostate PTV-D$_{95}$ $\mathrm{\sim}$ -0.6%). Conclusion: The results confirm the capability of GATE simulation as a reliable surrogate for verifying TPS dose maps prior to patient treatment.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Calorimetry for low-energy electrons using charge and light in liquid argon
Authors:
W. Foreman,
R. Acciarri,
J. A. Asaadi,
W. Badgett,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
J. Evans,
A. Falcone,
W. Flanagan,
B. T. Fleming,
D. Garcia-Gomez,
B. Gelli,
T. Ghosh,
R. A. Gomes,
E. Gramellini,
R. Gran,
P. Hamilton,
C. Hill,
J. Ho,
J. Hugon
, et al. (38 additional authors not shown)
Abstract:
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-…
▽ More
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stop** cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT's well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $σ/E \simeq 9.3\%/\sqrt{E} \oplus 1.3\%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $\simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $\approx$ 10%, $\approx$ 20%, and $\approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.
△ Less
Submitted 22 January, 2020; v1 submitted 17 September, 2019;
originally announced September 2019.
-
PennyLane: Automatic differentiation of hybrid quantum-classical computations
Authors:
Ville Bergholm,
Josh Izaac,
Maria Schuld,
Christian Gogolin,
Shahnawaz Ahmed,
Vishnu Ajith,
M. Sohaib Alam,
Guillermo Alonso-Linaje,
B. AkashNarayanan,
Ali Asadi,
Juan Miguel Arrazola,
Utkarsh Azad,
Sam Banning,
Carsten Blank,
Thomas R Bromley,
Benjamin A. Cordier,
Jack Ceroni,
Alain Delgado,
Olivia Di Matteo,
Amintor Dusko,
Tanya Garg,
Diego Guala,
Anthony Hayes,
Ryan Hill,
Aroosa Ijaz
, et al. (43 additional authors not shown)
Abstract:
PennyLane is a Python 3 software framework for differentiable programming of quantum computers. The library provides a unified architecture for near-term quantum computing devices, supporting both qubit and continuous-variable paradigms. PennyLane's core feature is the ability to compute gradients of variational quantum circuits in a way that is compatible with classical techniques such as backpro…
▽ More
PennyLane is a Python 3 software framework for differentiable programming of quantum computers. The library provides a unified architecture for near-term quantum computing devices, supporting both qubit and continuous-variable paradigms. PennyLane's core feature is the ability to compute gradients of variational quantum circuits in a way that is compatible with classical techniques such as backpropagation. PennyLane thus extends the automatic differentiation algorithms common in optimization and machine learning to include quantum and hybrid computations. A plugin system makes the framework compatible with any gate-based quantum simulator or hardware. We provide plugins for hardware providers including the Xanadu Cloud, Amazon Braket, and IBM Quantum, allowing PennyLane optimizations to be run on publicly accessible quantum devices. On the classical front, PennyLane interfaces with accelerated machine learning libraries such as TensorFlow, PyTorch, JAX, and Autograd. PennyLane can be used for the optimization of variational quantum eigensolvers, quantum approximate optimization, quantum machine learning models, and many other applications.
△ Less
Submitted 29 July, 2022; v1 submitted 12 November, 2018;
originally announced November 2018.
-
The Intermediate Neutrino Program
Authors:
C. Adams,
J. R. Alonso,
A. M. Ankowski,
J. A. Asaadi,
J. Ashenfelter,
S. N. Axani,
K. Babu,
C. Backhouse,
H. R. Band,
P. S. Barbeau,
N. Barros,
A. Bernstein,
M. Betancourt,
M. Bishai,
E. Blucher,
J. Bouffard,
N. Bowden,
S. Brice,
C. Bryan,
L. Camilleri,
J. Cao,
J. Carlson,
R. E. Carr,
A. Chatterjee,
M. Chen
, et al. (164 additional authors not shown)
Abstract:
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermedia…
▽ More
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermediate term, including possible new small to mid-scale experiments, US contributions to large experiments, upgrades to existing experiments, R&D plans and theory. The workshop was organized into two sets of parallel working group sessions, divided by physics topics and technology. Physics working groups covered topics on Sterile Neutrinos, Neutrino Mixing, Neutrino Interactions, Neutrino Properties and Astrophysical Neutrinos. Technology sessions were organized into Theory, Short-Baseline Accelerator Neutrinos, Reactor Neutrinos, Detector R&D and Source, Cyclotron and Meson Decay at Rest sessions.This report summarizes discussion and conclusions from the workshop.
△ Less
Submitted 1 April, 2015; v1 submitted 23 March, 2015;
originally announced March 2015.