-
Surface Passivation Method for Super-repellence of Aqueous Macromolecular Condensates
Authors:
Andrea Testa,
Hendrik T. Spanke,
Etienne Jambon-Puillet,
Mohammad Yasir,
Andreas M. Küffner,
Paolo Arosio,
Eric R. Dufresne,
Robert W. Style,
Aleksander A. Rebane
Abstract:
Solutions of macromolecules can undergo liquid-liquid phase separation to form droplets with ultra-low surface tension. Droplets with such low surface tension wet and spread over common surfaces such as test tubes and microscope slides, complicating \textit{in vitro} experiments. Development of an universal super-repellent surface for macromolecular droplets has remained elusive because their ultr…
▽ More
Solutions of macromolecules can undergo liquid-liquid phase separation to form droplets with ultra-low surface tension. Droplets with such low surface tension wet and spread over common surfaces such as test tubes and microscope slides, complicating \textit{in vitro} experiments. Development of an universal super-repellent surface for macromolecular droplets has remained elusive because their ultra-low surface tension requires low surface energies. Furthermore, nonwetting of droplets containing proteins poses additional challenges because the surface must remain inert to a wide range of chemistries presented by the various amino-acid side-chains at the droplet surface. Here, we present a method to coat microscope slides with a thin transparent hydrogel that exhibits complete dewetting (contact angles $θ\approx180^\circ)$ and minimal pinning of phase-separated droplets in aqueous solution. The hydrogel is based on a swollen matrix of chemically crosslinked polyethylene glycol diacrylate of molecular weight 12 kDa (PEGDA), and can be prepared with basic chemistry lab equipment. The PEGDA hydrogel is a powerful tool for \textit{in vitro} studies of weak interactions, dynamics, and internal organization of phase-separated droplets in aqueous solutions.
△ Less
Submitted 3 June, 2023;
originally announced June 2023.
-
Objective metrics for language lateralization of fMRI examinations: a new model for the classification of hemispheric dominance in healthy subjects and epileptic patients
Authors:
M. Stroppi,
D. Lizio,
L. Berta,
A. Citterio,
C. Regna-Gladin,
M. Rizzi,
I. Sartori,
P. E. Colombo,
P. Arosio,
A. Torresin
Abstract:
Purpose: to compare different methods to calculate Laterality Index (LI), a metric which allows to evaluate hemispheric brain language dominance in functional MRI examinations (fMRI).
Methods: Two methods were considered for calculating LI: LI AVE and LI VOL , respectively based on the differences between measurements of average and volume of fMRI signal in brain hemispheres. Laterality curves w…
▽ More
Purpose: to compare different methods to calculate Laterality Index (LI), a metric which allows to evaluate hemispheric brain language dominance in functional MRI examinations (fMRI).
Methods: Two methods were considered for calculating LI: LI AVE and LI VOL , respectively based on the differences between measurements of average and volume of fMRI signal in brain hemispheres. Laterality curves were obtained calculating values of LI VOL with increasing thresholds of fMRI signal and fitted with sigmoidal functions. A model for dominant and co-dominant classification based on fit parameters has been developed. The two methods and the sigmoidal model were applied to two cohorts of 93 epileptic patients and 27 healthy subjects undergoing language fMRI examinations with association, understanding and fluency tasks.
Results: Despite the different definitions, LI AVE and LI VOL resulted in equivalent classification of language lateralization. The agreement of neuroradiological clinical reports with classification of language lateralization resulting from the proposed methods ranged from 94.6% to 89.2% for LI metrics and up to 100% for the sigmoidal model. The fit parameters of the sigmoidal function defined empirical thresholds useful for classification between dominant and co-dominant, providing similar values for subjects and epileptic patients for fluency and association tasks. This result supports the idea of a unique model for language lateralization classification in epileptic patients and healthy subjects.
Conclusions: Language lateralization in fMRI can be effectively assessed by objective metrics. A novel approach based on sigmoidal fit of laterality curves resulted in higher agreement with clinical reports providing further information about the strength of language lateralization.
△ Less
Submitted 27 September, 2021;
originally announced September 2021.
-
Experimental determination of the frequency and field dependence of Specific Loss Power in Magnetic Fluid Hyperthermia
Authors:
M. Cobianchi,
A. Guerrini,
M. Avolio,
C. Innocenti,
M. Corti,
P. Arosio,
F. Orsini,
C. Sangregorio,
A. Lascialfari
Abstract:
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples…
▽ More
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples having a magnetic core of maghemite with different core diameter d= 10.2, 14.6 and 19.7 nm. The SLP was measured as a function of frequency f and intensity of the applied alternating magnetic field H, and it turned out to depend on the core diameter, as expected. The results allowed us to highlight experimentally that the physical mechanism responsible for the heating is size-dependent and to establish, at applied constant frequency, the phenomenological functional relationship SLP=cH^x, with 2<x<3 for all samples. The x-value depends on sample size and field frequency/ intensity, here chosen in the typical range of operating magnetic hyperthermia devices. For the smallest sample, the effective relaxation time Teff=19.5 ns obtained from SLP data is in agreement with the value estimated from magnetization data, thus confirming the validity of the Linear Response Theory model for this system at properly chosen field intensity and frequency.
△ Less
Submitted 10 April, 2017;
originally announced April 2017.
-
Particle-based simulations of steady-state mass transport at high Péclet numbers
Authors:
Thomas Müller,
Paolo Arosio,
Luke Rajah,
Samuel I. A. Cohen,
Emma V. Yates,
Michele Vendruscolo,
Chrisopher M. Dobson,
Tuomas P. J. Knowles
Abstract:
Conventional approaches for simulating steady-state distributions of particles under diffusive and advective transport at high Péclet numbers involve solving the diffusion and advection equations in at least two dimensions. Here, we present an alternative computational strategy by combining a particle-based rather than a field-based approach with the initialisation of particles in proportion to th…
▽ More
Conventional approaches for simulating steady-state distributions of particles under diffusive and advective transport at high Péclet numbers involve solving the diffusion and advection equations in at least two dimensions. Here, we present an alternative computational strategy by combining a particle-based rather than a field-based approach with the initialisation of particles in proportion to their flux. This method allows accurate prediction of the steady state and is applicable even at high Péclet numbers where traditional particle-based Monte-Carlo methods starting from randomly initialised particle distributions fail. We demonstrate that generating a flux of particles according to a predetermined density and velocity distribution at a single fixed time and initial location allows for accurate simulation of mass transport under flow. Specifically, upon initialisation in proportion to their flux, these particles are propagated individually and detected by summing up their Monte-Carlo trajectories in predefined detection regions. We demonstrate quantitative agreement of the predicted concentration profiles with the results of experiments performed with fluorescent particles in microfluidic channels under continuous flow. This approach is computationally advantageous and readily allows non-trivial initial distributions to be considered. In particular, this method is highly suitable for simulating advective and diffusive transport in microfluidic devices.
△ Less
Submitted 17 October, 2015;
originally announced October 2015.