-
The ACCEL$^2$ project: simulating Lyman-$α$ forest in large-volume hydrodynamical simulations
Authors:
Solène Chabanier,
Corentin Ravoux,
Lucas Latrille,
Jean Sexton,
Éric Armengaud,
Julian Bautista,
Tyann Dumerchat,
Zarija Lukić
Abstract:
Cosmological information is usually extracted from the Lyman-$α$ forest correlations using only either large-scale information interpreted through linear theory or using small-scale information interpreted by means of expensive hydrodynamical simulations. A complete cosmological interpretation of the 3D correlations at all measurable scales is challenged by the need of more realistic models includ…
▽ More
Cosmological information is usually extracted from the Lyman-$α$ forest correlations using only either large-scale information interpreted through linear theory or using small-scale information interpreted by means of expensive hydrodynamical simulations. A complete cosmological interpretation of the 3D correlations at all measurable scales is challenged by the need of more realistic models including the complex growth of non-linear small scales that can only be studied within large hydrodynamical simulations. Past work were often limited by the trade off between the simulated cosmological volume and the resolution of the low-density intergalactic medium from which the Lyman-$α$ signal originates. We conduct a suite of hydrodynamical simulations of the intergalactic medium, including one of the largest Lyman-$α$ simulations ever performed in terms of volume (640 $h^{-1}\mathrm{Mpc}$), alongside simulations in smaller volumes with resolutions up to 25 $h^{-1}\mathrm{kpc}$. We compare the 3D Lyman-$α$ power spectra predicted by those simulations to different non-linear models. The inferred Lyman-$α$ bias and RSD parameters, $b_α$ and $β_α$ are in remarkable agreement with those measured in SDSS and DESI data. We find that, contrary to intuition, the convergence of large-scale modes of the 3D Lyman-$α$ power spectra, which determines $β_α$, is primarily influenced by the resolution of the simulation box through mode coupling, rather than the box size itself. Finally, we study the BAO signal encoded in the 3D Lyman-$α$ power spectra. For the first time with a hydrodynamical simulation, we clearly detect the BAO signal, however we only marginally detect its dam**, associated with the non-linear growth of the structures.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
High impedance TES bolometers for EDELWEISS
Authors:
S. Marnieros,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. -B. Fillipini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud,
D. Misiak
, et al. (13 additional authors not shown)
Abstract:
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge bolometers equipped with high impedance thermistors based on a NbxSi1-x TES alloy. High aspect ratio spiral designs allow the TES impedance to match with JFET or HEMT…
▽ More
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge bolometers equipped with high impedance thermistors based on a NbxSi1-x TES alloy. High aspect ratio spiral designs allow the TES impedance to match with JFET or HEMT front-end amplifiers. We detail the behavior of the superconducting transition properties of these sensors and the detector optimization in terms of sensitivity to out-of-equilibrium phonons. We report preliminary results of a 200 g Ge detector that was calibrated using 71Ge activation by neutrons at the LSM underground laboratory.
△ Less
Submitted 5 January, 2022;
originally announced January 2022.
-
Low-mass Dark Matter searches with EDELWEISS
Authors:
J. Gascon,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. -B. Filippini,
D. Filosofov,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud,
S. Marnieros,
D. Misiak
, et al. (13 additional authors not shown)
Abstract:
The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was obtained on a massive (33.4 g) Ge detector operated underground at the Laboratoire Souterrain de Modane. This record sensitivity made possible a search for Dark…
▽ More
The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was obtained on a massive (33.4 g) Ge detector operated underground at the Laboratoire Souterrain de Modane. This record sensitivity made possible a search for Dark Photon DM down to 1 eV/c2 and to DM-electron interactions below 1 MeV/c2. This demonstrates for the first time the high relevance of cryogenic Ge detectors in searches at low thresholds and is an important step of the development of Ge detectors with improved performance in the context of the EDELWEISS-SubGeV program.
△ Less
Submitted 10 March, 2022; v1 submitted 10 December, 2021;
originally announced December 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Pulse Shape Discrimination in CUPID-Mo using Principal Component Analysis
Authors:
R. Huang,
E. Armengaud,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
A. Benoît,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
Ch. Bourgeois,
V. B. Brudanin,
P. Camus,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
T. Dixon,
L. Dumoulin
, et al. (64 additional authors not shown)
Abstract:
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $α$ backgrounds, drastically reducing the expected background in the $0νββ$ signal region. As a result, pileup events and small detector instab…
▽ More
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $α$ backgrounds, drastically reducing the expected background in the $0νββ$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.
△ Less
Submitted 23 March, 2021; v1 submitted 8 October, 2020;
originally announced October 2020.
-
First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment
Authors:
EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
E. Elkhoury,
J. -B. Fillipini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud
, et al. (17 additional authors not shown)
Abstract:
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting…
▽ More
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting with electrons, as well as on dark photons down to 1 eV/c$^2$. These are competitive with other searches. In particular, new limits are set on the kinetic mixing of dark photon DM in a so far unconstrained parameter space region in the 6 to 9 eV/c$^2$ mass range. These results demonstrate the high relevance of cryogenic Ge detectors for the search of DM interactions producing eV-scale electron signals.
△ Less
Submitted 10 March, 2022; v1 submitted 2 March, 2020;
originally announced March 2020.
-
Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
A. Benoît,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
Ch. Bourgeois,
M. Briere,
V. Brudanin,
P. Camus,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
L. Dumoulin,
K. Eitel
, et al. (65 additional authors not shown)
Abstract:
We report the measurement of the two-neutrino double-beta ($2νββ$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of…
▽ More
We report the measurement of the two-neutrino double-beta ($2νββ$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2ν}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2νββ$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3σ$, that the single-state dominance model of the $2νββ$ decay of $^{100}$Mo is favored over the high-state dominance model.
△ Less
Submitted 16 December, 2019;
originally announced December 2019.
-
First data from the CUPID-Mo neutrinoless double beta decay experiment
Authors:
B. Schmidt,
E. Armengaud,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
A. Benoît,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
Ch. Bourgeois,
M. Briere,
V. B. Brudanin,
P. Camus,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
L. Dumoulin
, et al. (65 additional authors not shown)
Abstract:
The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both hea…
▽ More
The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $α$ from $γ$&$β$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $α$ separation of better than 99.9\% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0ν}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.
△ Less
Submitted 23 November, 2019;
originally announced November 2019.
-
The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
A. Benoît,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
Ch. Bourgeois,
M. Briere,
V. B. Brudanin,
P. Camus,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
L. Dumoulin,
K. Eitel
, et al. (64 additional authors not shown)
Abstract:
CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO…
▽ More
CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO$_4$ crystals. The detectors are complemented by 20 thin cryogenic Ge bolometers acting as light detectors to distinguish $α$ from $γ$/$β$ events by the detection of both heat and scintillation light signals. We observe good detector uniformity, facilitating the operation of a large detector array as well as excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Based on the observed energy resolutions and light yields a separation of $α$ particles at much better than 99.9\% with equally high acceptance for $γ$/$β$ events is expected for events in the region of interest for $^{100}$Mo $0νββ$. We present limits on the crystals' radiopurity ($\leq$3 $μ$Bq/kg of $^{226}$Ra and $\leq$2 $μ$Bq/kg of $^{232}$Th). Based on these initial results we also discuss a sensitivity study for the science reach of the CUPID-Mo experiment, in particular, the ability to set the most stringent half-life limit on the $^{100}$Mo $0νββ$ decay after half a year of livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology - developed in the framework of the LUMINEU project - selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale cryogenic $0νββ$ experiment.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoit,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapelier,
F. Charlieux,
D. Ducimetière,
L. Dumoulin,
K. Eitel,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
M. De Jésus,
Y. **,
A. Juillard,
M. Kleifges,
R. Maisonobe,
S. Marnieros,
D. Misiak
, et al. (16 additional authors not shown)
Abstract:
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding…
▽ More
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear recoil based, above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the dark matter search results were studied in the context of Strongly Interacting Massive Particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from $10^{-29}$ to $10^{-26}$~cm$^2$.
△ Less
Submitted 2 April, 2019; v1 submitted 11 January, 2019;
originally announced January 2019.
-
Searches for electron interactions induced by new physics in the EDELWEISS-III germanium bolometers
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
V. Kozlov,
H. Kraus,
V. A. Kudryavtsev,
H. Le-Sueur,
R. Maisonobe,
S. Marnieros
, et al. (17 additional authors not shown)
Abstract:
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters…
▽ More
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters $g_{ae}<1.1\times 10^{-11}$ and $g_{ae}\times g_{aN}^{\rm eff} < 3.5\times 10^{-17}$ at 90% C.L. in the massless limit. We also directly search for the absorption of bosonic dark matter particles that would constitute our local galactic halo. Limits are placed on the couplings of ALPs or hidden photon dark matter in the mass range $0.8 - 500$ keV/c$^2$. Prospects for searching for dark matter particles with masses down to 150 eV/c$^2$ using improved detectors are presented.
△ Less
Submitted 5 November, 2018; v1 submitted 7 August, 2018;
originally announced August 2018.
-
Complete event-by-event $α$/$γ(β)$ separation in a full-size TeO$_2$ CUORE bolometer by Neganov-Luke-magnified light detection
Authors:
L. Bergé,
M. Chapellier,
M. de Combarieu,
L. Dumoulin,
A. Giuliani,
M. Gros,
P. de Marcillac,
S. Marnieros,
C. Nones,
V. Novati,
E. Olivieri,
B. Paul,
D. V. Poda,
T. Redon,
B. Siebenborn,
A. S. Zolotarova,
E. Armengaud,
C. Augier,
A. Benoît,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
F. Charlieux,
M. De Jesus
, et al. (19 additional authors not shown)
Abstract:
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0νββ$) of $^{130}$Te. We demonstrate an efficient $α$ particle discrimination (99.9\%) with a high acceptance of the $0νββ$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the s…
▽ More
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0νββ$) of $^{130}$Te. We demonstrate an efficient $α$ particle discrimination (99.9\%) with a high acceptance of the $0νββ$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the superior performance (10 eV rms baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal from the TeO$_2$ detector, dominated by $γ$($β$)-induced Cherenkov radiation but exhibiting also a clear scintillation component. The obtained results represent a major breakthrough towards the TeO$_2$-based version of CUORE Upgrade with Particle IDentification (CUPID), a ton-scale cryogenic $0νββ$ experiment proposed as a follow-up to the CUORE project with particle identification. The CUORE experiment began recently a search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 125-cm$^3$ TeO$_2$ bolometers. The lack of $α$ discrimination in CUORE makes $α$ decays at the detector surface the dominant background component, at the level of $\approx 0.01$ counts/(keV kg y) in the region of interest. We show here, for the first time with a CUORE-size bolometer and using the same technology as CUORE for the readout of both heat and light signals, that surface $α$ background can be fully rejected.
△ Less
Submitted 25 April, 2018; v1 submitted 10 October, 2017;
originally announced October 2017.
-
Optimizing EDELWEISS detectors for low-mass WIMP searches
Authors:
EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
Y. **,
A. Juillard,
M. Kleifges,
V. Kozlov,
H. Kraus
, et al. (18 additional authors not shown)
Abstract:
The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal str…
▽ More
The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal strategy for detector optimization depends critically on whether the emphasis is put on WIMP masses below or above $\sim$ 5 GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon cross-section of $σ_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future hundred-kilogram scale experiment designed to reach the bounds imposed by the coherent scattering of solar neutrinos are also described. By improving the ionization resolution down to 50 eV$_{ee}$, we show that such an experiment installed in an even lower background environment (e.g. at SNOLAB) should allow to observe about 80 $^8$B neutrino events after discrimination.
△ Less
Submitted 11 July, 2017;
originally announced July 2017.
-
Performance of the EDELWEISS-III experiment for direct dark matter searches
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon,
A. Giuliani,
M. Grollier
, et al. (38 additional authors not shown)
Abstract:
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used…
▽ More
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $β$- and $α$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $α$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $γ$-ray events has been demonstrated using $γ$-calibrations with $^{133}$Ba sources leading to a value of $R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $γ$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
△ Less
Submitted 4 June, 2017;
originally announced June 2017.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III
Authors:
The EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
Y. **,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for…
▽ More
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for $^{65}$Zn. These results are the most accurate for these isotopes. A lower limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also presented. They are compared to model predictions present in literature and to estimates calculated with the ACTIVIA code.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach
Authors:
EDELWEISS Collaboration,
L. Hehn,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
G. Heuermann,
Y. **,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoi…
▽ More
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoils from $^{206}$Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on Boosted Decision Trees (BDT). For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90% C.L. exclusion limit set for WIMPs with $m_χ= 4\,\mathrm{GeV/}c^2$ is $1.6 \times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above $15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in good agreement.
△ Less
Submitted 20 September, 2016; v1 submitted 12 July, 2016;
originally announced July 2016.
-
Signals induced by charge-trap** in EDELWEISS FID detectors: analytical modeling and applications
Authors:
The EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
N. Foerster,
N. Fourches,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
M. De Jésus,
Y. **
, et al. (25 additional authors not shown)
Abstract:
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trap** significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID…
▽ More
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trap** significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity to the depth of the energy deposits, characterize the trap** in the crystals, perform heat and ionization energy corrections and improve the ionization baseline resolutions. These procedures are applied successfully to actual data.
△ Less
Submitted 29 June, 2016; v1 submitted 26 June, 2016;
originally announced June 2016.
-
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
Authors:
EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
J. Blümer,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon
, et al. (42 additional authors not shown)
Abstract:
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear rec…
▽ More
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an illustration the number of observed events in the search for 5 (resp. 20) GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1 (resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times 10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a 41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints of WIMP signals from some recent experiments, thus confirming results obtained with different detection techniques.
△ Less
Submitted 9 May, 2016; v1 submitted 16 March, 2016;
originally announced March 2016.
-
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO$_4$ scintillating bolometers
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
A. Benoit,
L. Berge,
R. S. Boiko,
T. Bergmann,
J. Blumer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
F. A. Danevich,
T. de Boissiere,
R. Decourt,
M. De Jesus,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin
, et al. (69 additional authors not shown)
Abstract:
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very prom…
▽ More
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the $α/β$ discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kg$\times$years, setting the bases for a next generation $0\nu2β$ decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Scintillating bolometers based on ZnMoO$_4$ and Zn$^{100}$MoO$_4$ crystals to search for 0$ν$2$β$ decay of $^{100}$Mo (LUMINEU project): first tests at the Modane Underground Laboratory
Authors:
D. V. Poda,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
R. S. Boiko,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
B. Censier,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
G. A. Cox,
F. A. Danevich,
T. de Boissière,
R. Decourt,
M. De Jesus
, et al. (69 additional authors not shown)
Abstract:
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed…
▽ More
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed and Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time by using the low-thermal-gradient Czochralski technique. One ZnMoO$_4$ scintillator and two samples (59 g and 63 g) cut from the enriched boule were tested aboveground at milli-Kelvin temperature as scintillating bolometers showing a high detection performance. The first results of the low background measurements with three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Modane Underground Laboratory (France) are presented.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Conceptual Design of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
F. T. Avignone,
M. Betz,
P. Brax,
P. Brun,
G. Cantatore,
J. M. Carmona,
G. P. Carosi,
F. Caspers,
S. Caspi,
S. A. Cetin,
D. Chelouche,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
B. Döbrich,
I. Dratchnev,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas
, et al. (63 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc…
▽ More
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
Background studies for the EDELWEISS dark matter experiment
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couedo,
P. Coulter,
G. A. Cox,
M. De Jesus,
J. Domange,
A. -A. Drilien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
M. Gros
, et al. (34 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present h…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ($\le0.9$), surface betas ($\le0.3$), and muon-induced neutrons ($\le0.7$), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.
△ Less
Submitted 15 May, 2013;
originally announced May 2013.
-
Muon-induced background in the EDELWEISS dark matter search
Authors:
The EDELWEISS collaboration,
B. Schmidt,
E. Armengaud,
C. Augier,
A. Benoit,
L. Bergé,
T. Bergmann,
J. Blümer,
G. Bres,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
S. Collin,
P. Coulter,
G. A. Cox,
O. Crauste,
J. Domange,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
G. Garde,
J. Gascon
, et al. (33 additional authors not shown)
Abstract:
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the…
▽ More
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events $Γ^μ=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $Γ^{μ-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be $Γ^{μ-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{μ-n}_{3000 kg\cdot d} < 0.6$ events.
△ Less
Submitted 28 February, 2013;
originally announced February 2013.
-
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Authors:
EDELWEISS Collaboration,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couëdo,
P. Coulter,
G. A. Cox,
J. Domange,
A. A. Drillien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
J. Gironnet,
M. Gros
, et al. (30 additional authors not shown)
Abstract:
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed…
▽ More
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
△ Less
Submitted 5 September, 2012; v1 submitted 7 July, 2012;
originally announced July 2012.
-
Preliminary results of a WIMP search with EDELWEISS-II cryogenic detectors
Authors:
E. Armengaud
Abstract:
The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode geometry were developped and validated, enabling an outstanding rejection of gamma-rays and surface interactions. We present here preliminary results of a one-…
▽ More
The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode geometry were developped and validated, enabling an outstanding rejection of gamma-rays and surface interactions. We present here preliminary results of a one-year WIMP search carried out with ten of such detectors in the Laboratoire Souterrain de Modane. A sensitivity to the spin-independent WIMP-nucleon cross-section of 5 \times 10-8 pb was achieved using a 322 kg
△ Less
Submitted 10 November, 2010;
originally announced November 2010.