-
Bayesian Optimization of High-Entropy Alloy Compositions for Electrocatalytic Oxygen Reduction
Authors:
Jack K. Pedersen,
Christian M. Clausen,
Olga A. Krysiak,
Bin Xiao,
Thomas A. A. Batchelor,
Tobias Löffler,
Vladislav A. Mints,
Lars Banko,
Matthias Arenz,
Alan Savan,
Wolfgang Schuhmann,
Alfred Ludwig,
Jan Rossmeisl
Abstract:
Active, selective and stable catalysts are imperative for sustainable energy conversion, and engineering materials with such properties are highly desired. High-entropy alloys (HEAs) offer a vast compositional space for tuning such properties. Too vast, however, to traverse without the proper tools. Here, we report the use of Bayesian optimization on a model based on density functional theory (DFT…
▽ More
Active, selective and stable catalysts are imperative for sustainable energy conversion, and engineering materials with such properties are highly desired. High-entropy alloys (HEAs) offer a vast compositional space for tuning such properties. Too vast, however, to traverse without the proper tools. Here, we report the use of Bayesian optimization on a model based on density functional theory (DFT) to predict the most active compositions for the electrochemical oxygen reduction reaction (ORR) with the least possible number of sampled compositions for the two HEAs Ag-Ir-Pd-Pt-Ru and Ir-Pd-Pt-Rh-Ru. The discovered optima are then scrutinized with DFT and subjected to experimental validation where optimal catalytic activities are verified for Ag-Pd, Ir-Pt, and Pd-Ru binary systems. This study offers insight into the number of experiments needed for exploring the vast compositional space of multimetallic alloys which has been determined to be on the order of 50 for ORR on these HEAs.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pum** sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (102 additional authors not shown)
Abstract:
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage divid…
▽ More
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
△ Less
Submitted 15 May, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
First transmission of electrons and ions through the KATRIN beamline
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (104 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons fr…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
△ Less
Submitted 7 July, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Commissioning of the vacuum system of the KATRIN Main Spectrometer
Authors:
M. Arenz,
M. Babutzka,
M. Bahr,
J. P. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
J. Blümer,
L. I. Bodine,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
S. Büsch,
T. H. Burritt,
S. Chilingaryan,
T. J. Corona,
L. De Viveiros,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (125 additional authors not shown)
Abstract:
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong m…
▽ More
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
△ Less
Submitted 3 March, 2016;
originally announced March 2016.