Skip to main content

Showing 1–22 of 22 results for author: Annand, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2311.00725  [pdf, other

    physics.ins-det nucl-ex

    Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons

    Authors: N. Mauritzson, K. G. Fissum, J. R. M. Annand, H. Perrey, R. Al Jebali, A. Backis, R. Hall-Wilton, K. Kanaki, V. Maulerova-Subert, F. Messi, R. J. W. Frost, E. Rofors, J. Scherzinger

    Abstract: Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge p… ▽ More

    Submitted 24 November, 2023; v1 submitted 31 October, 2023; originally announced November 2023.

    Comments: 31 pages, 15 figures, 4 tables

  2. arXiv:2211.16091  [pdf

    physics.ins-det hep-ex

    Advanced Radio Frequency Timing AppaRATus (ARARAT) Technique and Applications

    Authors: Ani Aprahamian, Amur Margaryan, Vanik Kakoyan, Simon Zhamkochyan, Sergey Abrahamyan, Hayk Elbakyan, Samvel Mayilyan, Arpine Piloyan, Henrik Vardanyan, Hamlet Zohrabyan, Lekdar Gevorgian, Robert Ayvazyan, Artashes Papyan, Garnik Ayvazyan, Arsen Ghalumyan, Narek Margaryan, Hasmik Rostomyan, Anna Safaryan, Bagrat Grigoryan, Ashot Vardanyan, Arsham Yeremyan, John Annand, Kenneth Livingston, Rachel Montgomery, Patrick Achenbach , et al. (6 additional authors not shown)

    Abstract: The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, bas… ▽ More

    Submitted 29 November, 2022; originally announced November 2022.

    Comments: 15 pages, 7 figures. arXiv admin note: text overlap with arXiv:2203.09194

  3. arXiv:2206.00948  [pdf, other

    physics.ins-det nucl-ex

    Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons

    Authors: N. Mauritzson, K. G. Fissum, J. R. M. Annand, H. Perrey, R. J. W. Frost, R. Al Jebali, A. Backis, R. Hall-Wilton, K. Kanaki, V. Maulerova-Subert, C. Maurer, F. Messi, E. Rofors

    Abstract: Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray even… ▽ More

    Submitted 2 June, 2022; originally announced June 2022.

    Comments: 22 pages, 12 figures, 2 tables

  4. An RF Timer of Electrons and Photons with the Potential to reach Picosecond Precision

    Authors: Amur Margaryan, Vanik Kakoyan, Simon Zhamkochyan, Sergey Abrahamyan, Hayk Elbakyan, Samvel Mayilyan, Henrik Vardanyan, Hamlet Zohrabyan, Lekdar Gevorgian, Robert Ayvazyan, Artashes Papyan, Garnik Ayvazyan, Bagrat Grigoryan, John Annand, Kenneth Livingston, Rachel Montgomery, Patrick Achenbach, Josef Pochodzalla, Dimiter L. Balabanski, Satoshi N. Nakamura

    Abstract: This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on s… ▽ More

    Submitted 20 May, 2022; v1 submitted 17 March, 2022; originally announced March 2022.

    Comments: 12 pages, 7 figures

  5. arXiv:2109.11963  [pdf, other

    physics.ins-det nucl-ex

    Geant4-based calibration of an organic liquid scintillator

    Authors: N. Mauritzson, K. G. Fissum, H. Perrey, J. R. M. Annand, R. J. W. Frost, R. Hall-Wilton, R. Al Jebali, K. Kanaki, V. Maulerova, F. Messi, E. Rofors

    Abstract: A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detec… ▽ More

    Submitted 22 October, 2021; v1 submitted 24 September, 2021; originally announced September 2021.

    Comments: 20 pages, 8 figures, 4 tables

  6. arXiv:2012.10843  [pdf, other

    nucl-ex nucl-th physics.acc-ph

    International Workshop on Next Generation Gamma-Ray Source

    Authors: C. R. Howell, M. W. Ahmed, A. Afanasev, D. Alesini, J. R. M. Annand, A. Aprahamian, D. L. Balabanski, S. V. Benson, A. Bernstein, C. R. Brune, J. Byrd, B. E. Carlsten, A. E. Champagne, S. Chattopadhyay, D. Davis, E. J. Downie, M. J. Durham, G. Feldman, H. Gao, C. G. R. Geddes, H. W. Griesshammer, R. Hajima, H. Hao, D. Hornidge, J. Isaak , et al. (28 additional authors not shown)

    Abstract: A workshop on The Next Generation Gamma-Ray Sources sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To an… ▽ More

    Submitted 19 December, 2020; originally announced December 2020.

  7. arXiv:2010.15695  [pdf, other

    physics.ins-det physics.comp-ph

    Simulation of the Response of the Solid State Neutron Detector for the European Spallation Source

    Authors: L. Boyd, E. Rofors, J. R. M. Annand, K. G. Fissum, R. Hall-Wilton, R. Al Jebali, K. Kanaki, K. Livingston, V. Maulerova, N. Mauritzson, R. Montgomery, H. Perrey, B. Seitz

    Abstract: The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, sc… ▽ More

    Submitted 11 March, 2021; v1 submitted 29 October, 2020; originally announced October 2020.

    Comments: Preprint 22 pages, 12 figures, published in NIM A

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A, Volume 998, 11 May 2021, 165174

  8. arXiv:2010.06347  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Authors: E. Rofors, N. Mauritzson, H. Perrey, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, R. Engels, K. G. Fissum, H. Frielinghaus, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, S. Kazi, G. Kemmerling, I. Llamas Jansa, V. Maulerova, R. Montgomery, T. Richter, J. Scherzinger, B. Seitz, M. Shetty

    Abstract: The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube… ▽ More

    Submitted 9 December, 2020; v1 submitted 13 October, 2020; originally announced October 2020.

    Comments: 23 pages, 8 figures

  9. arXiv:2005.08675  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams

    Authors: E. Rofors, J. Pallon, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, M. Elfman, R. Engels, K. G. Fissum, H. Frielinghaus, R. Frost, S. Gardner, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, G. Kemmerling, P. Kristiansson, K. Livingston, V. Maulerova, N. Mauritzson, R. Montgomery, H. Perrey , et al. (4 additional authors not shown)

    Abstract: The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel… ▽ More

    Submitted 18 May, 2020; originally announced May 2020.

    Comments: 22 pages, 8 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A

  10. arXiv:1812.08854  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am

    Authors: E. Rofors, H. Perrey, R. Al Jebali, J. R. M. Annand, L. Boyd, U. Clemens, S. Desert, R. Engels, K. G. Fissum, H. Frielinghaus, C. Gheorghe, R. Hall-Wilton, S. Jaksch, A. Jalgén, K. Kanaki, G. Kemmerling, V. Maulerova, N. Mauritzson, R. Montgomery, J. Scherzinger, B. Seitz

    Abstract: The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position an… ▽ More

    Submitted 19 December, 2018; originally announced December 2018.

    Comments: 23 pages, 7 figures, to be submitted to Nuclear Instruments and Methods in Physics Research Section A

  11. arXiv:1711.10286  [pdf

    physics.ins-det

    The neutron tagging facility at Lund University

    Authors: F. Messi, H. Perrey, K. Fissum, M. Akkawi, R. Al Jebali, J. R. M. Annand, P. Bentley, L. Boyd, C. P. Cooper-Jensen, D. D. DiJulio, J. Freita-Ramos, R. Hall-Wilton, A. Huusko, T. Ilves, F. Issa, A. Jalgén, K. Kanaki, E. Karnickis, A. Khaplanov, S. Koufigar, V. Maulerova, G. Mauri, N. Mauritzson, W. Pei, F. Piscitelli , et al. (5 additional authors not shown)

    Abstract: Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation p… ▽ More

    Submitted 28 November, 2017; originally announced November 2017.

    Comments: IAEA Technical Meeting on Modern Neutron Detection (F1-TM-55243)

  12. arXiv:1611.00213  [pdf, ps, other

    physics.ins-det nucl-ex

    A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources

    Authors: Julius Scherzinger, Ramsey Al Jebali, John Annand, Kevin Fissum, Richard Hall-Wilton, Sharareh Koufigar, Nicholai Mauritzson, Francesco Messi, Hanno Perrey, Emil Rofors

    Abstract: Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in an open environment using a CeBr3 detector and the same experimental conditions for both sources. The shapes of the distributions are very similar and agree well with previous data. Tagged-neutron measurements from 2 - 6… ▽ More

    Submitted 14 June, 2017; v1 submitted 1 November, 2016; originally announced November 2016.

    Comments: 16 pages, 6 figures

    Journal ref: Applied Radiation and Isotopes 127, 98-102 (2017)

  13. arXiv:1608.08778  [pdf, ps, other

    physics.ins-det nucl-ex

    The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons

    Authors: J. Scherzinger, R. Al Jebali, J. R. M. Annand, K. G. Fissum, R. Hall-Wilton, K. Kanaki, M. Lundin, B. Nilsson, H. Perrey, A. Rosborg, H. Svensson

    Abstract: The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of t… ▽ More

    Submitted 1 November, 2016; v1 submitted 31 August, 2016; originally announced August 2016.

    Comments: 10 pages, 7 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A, Referee comments addressed

    Journal ref: Nucl. Instr. and Meth. in Phys. Res. A 840 (2016) 121

  14. arXiv:1608.01126  [pdf, ps, other

    physics.ins-det nucl-ex

    High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination

    Authors: A. Margaryan, J. R. M. Annand, P. Achenbach, R. Ajvazyan, H. Elbakyan, R. Montgomery, S. N. Nakamura, J. Pochodzalla, F. Schulz, Y. Toyama, S. Zhamkochyan

    Abstract: We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency… ▽ More

    Submitted 3 August, 2016; originally announced August 2016.

    Comments: 22 pages, 13 figures

  15. arXiv:1503.05545  [pdf, other

    physics.ins-det nucl-ex

    A Helium Gas-Scintillator Active Target for Photoreaction Measurements

    Authors: R. Al Jebali, J. R. M. Annand, J. -O. Adler, I. Akkurt, E. Buchanan, J. Brudvik, K. Fissum, S. Gardner, D. J. Hamilton, K. Hansen, L. Isaksson, K. Livingston, M. Lundin, J. C. McGeorge, I. J. D. MacGregor, R. MacRae, D. G. Middleton, A. J. H. Reiter, G. Rosner, B. Schröder, J. Sjögren, D. Sokhan, B. Strandberg

    Abstract: A multi-cell He gas-scintillator active target, designed for the measurement of photoreaction cross sections, is described. The target has four main chambers, giving an overall thickness of 0.103 $\mathrm{g/cm^{2}}$ at an operating pressure of 2 MPa. Scintillations are read out by photomultiplier tubes and the addition of small amounts of $\mathrm{N}_{2}$ to the He, to shift the scintillation emis… ▽ More

    Submitted 18 March, 2015; originally announced March 2015.

    Comments: 24 pages, 15 figures

  16. arXiv:1502.07317  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector

    Authors: M. Martemianov, V. Kulikov, B. T. Demissie, Z. Marinides, C. S. Akondi, J. R. M. Annand, H. J. Arends, R. Beck, N. Borisov, A. Braghieri, W. J. Briscoe, S. Cherepnya, C. Collicott, S. Costanza, E. J. Downie, M. Dieterle, M. I. Ferretti Bondy, L. V. Filkov, S. Garni, D. I. Glazier, D. Glowa, W. Gradl, G. Gurevich, D. Hornidge, G. M. Huber , et al. (46 additional authors not shown)

    Abstract: We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single p0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.

    Submitted 25 February, 2015; originally announced February 2015.

  17. arXiv:1502.03931  [pdf, ps, other

    physics.ins-det nucl-ex

    A First Comparison of the responses of a He4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

    Authors: R. Jebali, J. Scherzinger, J. R. M. Annand, R. Chandra, G. Davatz, K. G. Fissum, H. Friederich, U. Gendotti, R. Hall-Wilton, E. Håkansson, K. Kanaki, M. Lundin, D. Murer, B. Nilsson, A. Rosborg, H. Svensson

    Abstract: A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between… ▽ More

    Submitted 27 April, 2015; v1 submitted 13 February, 2015; originally announced February 2015.

    Comments: 23 pages, 7 figures, Nuclear Instruments and Methods in Physics Research Section A review addressed

  18. arXiv:1409.4593  [pdf, other

    physics.acc-ph physics.ins-det

    A Radio Frequency Helical Deflector for keV Electrons

    Authors: Leckdar Gevorgian, Robert Ajvazyan, Vanik Kakoyan, Amur Margaryan, John Annand

    Abstract: This paper describes a helical deflector to perform circular sweeps of keV electrons by means of radio frequency fields in a frequency range 500-1000 MHz. By converting the time dependence of incident electrons to a hit position dependence on a circle, this device can potentially achieve extremely precise timing. The system can be adjusted to the velocity of the electrons to exclude the reduction… ▽ More

    Submitted 16 September, 2014; originally announced September 2014.

    Comments: 11 pages, 7 figures

  19. arXiv:1405.2686  [pdf, ps, other

    physics.ins-det nucl-ex

    Tagging fast neutrons from an 241Am/9Be source

    Authors: J. Scherzinger, J. R. M. Annand, G. Davatz, K. G. Fissum, U. Gendotti, R. Hall-Wilton, A. Rosborg, E. Håkansson, R. Jebali, K. Kanaki, M. Lundin, B. Nilsson, H. Svensson

    Abstract: We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.

    Submitted 3 January, 2015; v1 submitted 12 May, 2014; originally announced May 2014.

    Comments: 17 pages, 7 figures, submitted to Journal of Applied Radiation and Isotopes

    Journal ref: Applied Radiation and Isotopes 98 (2015) 74

  20. arXiv:1311.5692  [pdf, ps, other

    physics.ins-det nucl-ex

    Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory

    Authors: M. F. Preston, L. S. Myers, J. R. M. Annand, K. G. Fissum, K. Hansen, L. Isaksson, R. Jebali, M. Lundin

    Abstract: Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs.… ▽ More

    Submitted 22 November, 2013; originally announced November 2013.

    Comments: 10 pages, 8 figures, to be submitted to Nuclear Instruments and Methods in Physics Research Section A

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A 744, 17 (2014)

  21. arXiv:1302.4324  [pdf, other

    physics.ins-det nucl-ex

    Hall A Annual Report 2012

    Authors: S. Riordan, C. Keppel, K. Aniol, J. Annand, J. Arrington, T. Averett, C. Ayerbe Gayoso, E. Brash, G. D. Cates, J. -P. Chen, E. Chudakov, D. Flay, G. B. Franklin, M. Friedman, O. Glamazdin, J. Gomez, C. Hanretty, J. -O. Hansen, C. Hyde, M. K. Jones, I. Korover, J. J. LeRose, R. A. Lindgren, N. Liyanage, E. Long , et al. (24 additional authors not shown)

    Abstract: Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.

    Submitted 18 February, 2013; originally announced February 2013.

  22. arXiv:0704.1830  [pdf, ps, other

    physics.ins-det nucl-ex

    An Electromagnetic Calorimeter for the JLab Real Compton Scattering Experiment

    Authors: D. J. Hamilton, A. Shahinyan, B. Wojtsekhowski, J. R. M. Annand, T. -H. Chang, E. Chudakov, A. Danagoulian, P. Degtyarenko, K. Egiyan, R. Gilman, V. Gorbenko, J. Hines, E. Hovhannisyan, C. E. Hyde-Wright, C. W. de Jager, A. Ketikyan, V. H. Mamyan, R. Michaels, A. M. Nathan, V. Nelyubin, I. Rachek, M. Roedelbrom, A. Petrosyan, R. Pomatsalyuk, V. Popov , et al. (4 additional authors not shown)

    Abstract: A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the… ▽ More

    Submitted 25 September, 2015; v1 submitted 14 April, 2007; originally announced April 2007.

    Comments: text updated according to published version

    Report number: JLAB-PHY-07-633

    Journal ref: Nuclear Instruments and Methods A, Volume 643, Issue 1, 1 July 2011, Pages 17-28