-
Construction of Precision sMDT Detector for ATLAS Muon Spectrometer Upgrade
Authors:
D. Amidei,
N. Anderson,
A. Chen,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
Y. Guo,
J. Li,
X. Meng,
K. Nelson,
V. Pillsbury,
E. Salzer,
T. Schwarz,
L. Simpson,
Z. Wang,
C. Weaverdyck,
C. Wei,
Z. Yang,
M. Yuan,
B. Zhou,
J. Zhu
Abstract:
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms f…
▽ More
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 +- 7 microns with an average detection efficiency above 99 %. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade
Authors:
C. Wei,
A. Chen,
D. Amidei,
N. Anderson,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
J. Li,
P. Lugato,
J. Minnella,
S. Moskaitis,
K. Nelson,
V. Pillsbury,
E. Salzer,
L. Simpson,
Z. C. Wang,
Z. R. Wang,
C. Weaverdyck,
Z. Yang,
B. Zhou
Abstract:
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in d…
▽ More
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. These tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
Halogen Bonding Interactions: Revised Benchmarks and a New Assessment of Exchange vs. Dispersion
Authors:
Lindsey N. Anderson,
Fredy W. Aquino,
Alexandra E. Raeber,
Xi Chen,
Bryan M. Wong
Abstract:
We present a new analysis of exchange and dispersion effects for calculating halogen-bonding interactions in a wide variety of complex dimers (69 total) within the XB18 and XB51 benchmark sets. Contrary to previous work on these systems, we find that dispersion plays a more significant role than exact exchange in accurately calculating halogen-bonding interaction energies, which are further confir…
▽ More
We present a new analysis of exchange and dispersion effects for calculating halogen-bonding interactions in a wide variety of complex dimers (69 total) within the XB18 and XB51 benchmark sets. Contrary to previous work on these systems, we find that dispersion plays a more significant role than exact exchange in accurately calculating halogen-bonding interaction energies, which are further confirmed by extensive SAPT analyses. In particular, we find that even if the amount of exact exchange is non-empirically tuned to satisfy known DFT constraints, we still observe an overall improvement in predicting dissociation energies when dispersion corrections are applied, in stark contrast to previous studies (J. Chem. Theory Comput. 2013, 9, 1918-1931). In addition to these new analyses, we correct several (14) inconsistencies in the XB51 set, which is widely used in the scientific literature for develo** and benchmarking various DFT methods. Together, these new analyses and revised benchmarks emphasize the importance of dispersion and provide corrected reference values that are essential for develo**/parameterizing new DFT functionals specifically for complex halogen-bonding interactions.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Accurate Electron Affinities and Orbital Energies of Anions from a Non-Empirically Tuned Range-Separated Density Functional Theory Approach
Authors:
Lindsey N. Anderson,
M. Belén Oviedo,
Bryan M. Wong
Abstract:
The treatment of atomic anions with Kohn-Sham density functional theory (DFT) has long been controversial since the highest occupied molecular orbital (HOMO) energy, $E_{HOMO}$, is often calculated to be positive with most approximate density functionals. We assess the accuracy of orbital energies and electron affinities for all three rows of elements in the periodic table (H-Ar) using a variety o…
▽ More
The treatment of atomic anions with Kohn-Sham density functional theory (DFT) has long been controversial since the highest occupied molecular orbital (HOMO) energy, $E_{HOMO}$, is often calculated to be positive with most approximate density functionals. We assess the accuracy of orbital energies and electron affinities for all three rows of elements in the periodic table (H-Ar) using a variety of theoretical approaches and customized basis sets. Among all of the theoretical methods studied here, we find that a non-empirically tuned range-separated approach (constructed to satisfy DFT-Koopmans' theorem for the anionic electron system) provides the best accuracy for a variety of basis sets - even for small basis sets where most functionals typically fail. Previous approaches to solve this conundrum of positive $E_{HOMO}$ values have utilized non-self-consistent methods; however electronic properties, such as electronic couplings/gradients (which require a self-consistent potential and energy), become ill-defined with these approaches. In contrast, the non-empirically tuned range-separated procedure used here yields well-defined electronic couplings/gradients and correct $E_{HOMO}$ values since both the potential and resulting electronic energy are computed self-consistently. Orbital energies and electron affinities are further analyzed in the context of the electronic energy as a function of electronic number (including fractional numbers of electrons) to provide a stringent assessment of self-interaction errors for these complex anion systems.
△ Less
Submitted 19 March, 2019; v1 submitted 3 March, 2018;
originally announced March 2018.
-
MARS-MD: rejection based image domain material decomposition
Authors:
C. J. Bateman,
D. Knight,
B. Brandwacht,
J. Mc Mahon,
J. Healy,
R. Panta,
R. Aamir,
K. Rajendran,
M. Moghiseh,
M. Ramyar,
D. Rundle,
J. Bennett,
N. de Ruiter,
D. Smithies,
S. T. Bell,
R. Doesburg,
A. Chernoglazov,
V. B. H. Mandalika,
M. Walsh,
M. Shamshad,
M. Anjomrouz,
A. Atharifard,
L. Vanden Broeke,
S. Bheesette,
T. Kirkbride
, et al. (6 additional authors not shown)
Abstract:
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problem…
▽ More
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problems, each containing fewer materials; (2) solving each sub-problem; and (3) applying rejection criteria to eliminate all but one sub-problem's solution. An advantage of this process is that different constraints can be applied to each sub-problem if necessary. In addition, the result of this process is that solutions will be sparse in the material domain, which reduces crossover of signal between material images. Two algorithms based on this process are presented: the Segmentation variant, which uses segmented material classes to define each sub-problem; and the Angular Rejection variant, which defines the rejection criteria using the angle between reconstructed attenuation vectors.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Combined visible and near-infrared OPA for wavelength scaling experiments in strong-field physics
Authors:
David T. Lloyd,
Kevin O'Keeffe,
Adam S. Wyatt,
Patrick N. Anderson,
Daniel Treacher,
Simon M. Hooker
Abstract:
We report the operation of an optical parametric amplifier (OPA) capable of producing gigawatt peak-power laser pulses with tunable wavelength in either the visible or near-infrared spectrum. The OPA has two distinct operation modes (i) generation of >350 uJ, sub 100 fs pulses, tunable between 1250 - 1550 nm; (ii) generation of >190 uJ, sub 150 fs pulses tunable between 490 - 530 nm. We have recor…
▽ More
We report the operation of an optical parametric amplifier (OPA) capable of producing gigawatt peak-power laser pulses with tunable wavelength in either the visible or near-infrared spectrum. The OPA has two distinct operation modes (i) generation of >350 uJ, sub 100 fs pulses, tunable between 1250 - 1550 nm; (ii) generation of >190 uJ, sub 150 fs pulses tunable between 490 - 530 nm. We have recorded high-order harmonic spectra over a wide range of driving wavelengths. This flexible source of femtosecond pulses presents a useful tool for exploring the wavelength-dependence of strong-field phenomena, in both the multi-photon and tunnel ionization regimes.
△ Less
Submitted 7 March, 2017;
originally announced March 2017.
-
Spectral-gap immune characterization of electric fields
Authors:
Ilaria Gianani,
Charles Bourassin-Bouchet,
Patrick N. Anderson,
Matthias M. Mang,
Adam S. Wyatt,
Marco Barbieri,
Ian A. Walmsley
Abstract:
Synthesised light sources need reliable diagnostics for effective application to sub-femtosecond control and probing. However, commonly employed self-referencing techniques for pulsed-field characterisation fail in the presence of wide spectral gaps, while direct sampling methods are limited to high intensities. Here, we introduce a new approach labelled SPectral-gap Immune Characterisation of Ele…
▽ More
Synthesised light sources need reliable diagnostics for effective application to sub-femtosecond control and probing. However, commonly employed self-referencing techniques for pulsed-field characterisation fail in the presence of wide spectral gaps, while direct sampling methods are limited to high intensities. Here, we introduce a new approach labelled SPectral-gap Immune Characterisation of Electric Fields (SPICE), which overcomes these barriers by means of multi-spectral shearing interferometry, using an unknown reference and a reconstruction algorithm that makes use of this redundant information to simultaneously reconstruct the reference and test pulse with high precision and accuracy. We envisage that this technique will help foster new applications for broadband sources.
△ Less
Submitted 7 November, 2017; v1 submitted 20 December, 2016;
originally announced December 2016.
-
Gaussian-Schell analysis of the transverse spatial properties of high-harmonic beams
Authors:
David T. Lloyd,
Kevin O'Keeffe,
Patrick N. Anderson,
Simon M. Hooker
Abstract:
High harmonic generation (HHG) is an established means of producing coherent, short wavelength, ultrafast pulses from a compact set-up. Table-top high-harmonic sources are increasingly being used to image physical and biological systems using emerging techniques such as coherent diffraction imaging and ptychography. These novel imaging methods require coherent illumination, and it is therefore imp…
▽ More
High harmonic generation (HHG) is an established means of producing coherent, short wavelength, ultrafast pulses from a compact set-up. Table-top high-harmonic sources are increasingly being used to image physical and biological systems using emerging techniques such as coherent diffraction imaging and ptychography. These novel imaging methods require coherent illumination, and it is therefore important to both characterize the spatial coherence of high-harmonic beams and understand the processes which limit this property. Here we investigate the near- and far-field spatial properties of high-harmonic radiation generated in a gas cell. The variation with harmonic order of the intensity profile, wavefront curvature, and complex coherence factor is measured in the far-field by the SCIMITAR technique. Using the Gaussian-Schell model, the properties of the harmonic beam in the plane of generation are deduced. Our results show that the order-dependence of the harmonic spatial coherence is consistent with partial coherence induced by both variation of the intensity-dependent dipole phase as well as finite spatial coherence of the driving radiation. These findings are used to suggest ways in which the coherence of harmonic beams could be increased further, which would have direct benefits to imaging with high-harmonic radiation.
△ Less
Submitted 1 August, 2016;
originally announced August 2016.
-
Time-resolved energy transfer from single chloride terminated nanocrystals to graphene
Authors:
O. A. Ajayi,
N. C. Anderson,
M. Cotlet,
N. Petrone,
T. Gu,
A. Wolcott,
F. Gesuele,
J. Hone,
J. S. Owen,
C. W. Wong
Abstract:
We examine the time-resolved resonance energy transfer of excitons from single n-butyl amine-bound, chloride-terminated nanocrystals to two-dimensional graphene through time-correlated single photon counting. The radiative biexponential lifetime kinetics and blinking statistics of the individual surface-modified nanocrystal elucidate the non-radiative decay channels. Blinking modification as well…
▽ More
We examine the time-resolved resonance energy transfer of excitons from single n-butyl amine-bound, chloride-terminated nanocrystals to two-dimensional graphene through time-correlated single photon counting. The radiative biexponential lifetime kinetics and blinking statistics of the individual surface-modified nanocrystal elucidate the non-radiative decay channels. Blinking modification as well as a 4 times reduction in spontaneous emission were observed with the short chloride and n-butylamine ligands, probing the energy transfer pathways for the development of graphene-nanocrystal nanophotonic devices.
△ Less
Submitted 29 May, 2014;
originally announced May 2014.
-
Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science
Authors:
K. Rajendran,
M. F. Walsh,
N. J. A. de Ruiter,
A. I. Chernoglazov,
R. K. Panta,
A. P. H. Butler,
P. H. Butler,
S. T. Bell,
N. G. Anderson,
T. B. F. Woodfield,
S. J. Tredinnick,
J. L. Healy,
C. J. Bateman,
R. Aamir,
R. M. N. Doesburg,
P. F. Renaud,
S. P. Gieseg,
D. J. Smithies,
J. L. Mohr,
V. B. H. Mandalika,
A. M. T. Opie,
N. J. Cook,
J. P. Ronaldson,
S. J. Nik,
A. Atharifard
, et al. (6 additional authors not shown)
Abstract:
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routi…
▽ More
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routine. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. Narrow high energy acquisition using the photon-processing detector revealed substantial reduction in beam hardening effects and metal artefacts.
△ Less
Submitted 20 November, 2013;
originally announced November 2013.
-
MARS spectral molecular imaging of lamb tissue: data collection and image analysis
Authors:
R Aamir,
A Chernoglazov,
C J Bateman,
A P H Butler,
P H Butler,
N G Anderson,
S T Bell,
R K Panta,
J L Healy,
J L Mohr,
K Rajendran,
M F Walsh,
N de Ruiter,
S P Gieseg,
T Woodfield,
P F Renaud,
L Brooke,
S Abdul-Majid,
M Clyne,
R Glendenning,
P J Bones,
M Billinghurst,
C Bartneck,
H Mandalika,
R Grasset
, et al. (13 additional authors not shown)
Abstract:
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectros…
▽ More
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectroscopic photon-processing detector, to discriminate fat, calcium, and water in tissue. We present data collected from a sample of lamb meat including bone as an illustrative example of human tissue imaging. The data is analyzed using our 3D Algebraic Reconstruction Algorithm (MARS-ART) and by material decomposition based on a constrained linear least squares algorithm. The results presented here clearly show the quantification of lipid-like, water-like and bone-like components of tissue. However, it is also clear to us that better algorithms could extract more information of clinical interest from our data. Because we are one of the first to present data from multi-energy photon-processing small animal CT systems, we make the raw, partial and fully processed data available with the intention that others can analyze it using their familiar routines. The raw, partially processed and fully processed data of lamb tissue along with the phantom calibration data can be found at [http://hdl.handle.net/10092/8531].
△ Less
Submitted 23 January, 2014; v1 submitted 18 November, 2013;
originally announced November 2013.