-
Report on the AAPM Grand Challenge on deep generative modeling for learning medical image statistics
Authors:
Rucha Deshpande,
Varun A. Kelkar,
Dimitrios Gotsis,
Prabhat Kc,
Rong** Zeng,
Kyle J. Myers,
Frank J. Brooks,
Mark A. Anastasio
Abstract:
The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. The goal of this challenge was to promote the development of deep generative models (DGMs) for medical imaging and to emphasize the need for their domain-relevant assessment via the analysis of relevant image statistics. As part of this Grand Challeng…
▽ More
The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. The goal of this challenge was to promote the development of deep generative models (DGMs) for medical imaging and to emphasize the need for their domain-relevant assessment via the analysis of relevant image statistics. As part of this Grand Challenge, a training dataset was developed based on 3D anthropomorphic breast phantoms from the VICTRE virtual imaging toolbox. A two-stage evaluation procedure consisting of a preliminary check for memorization and image quality (based on the Frechet Inception distance (FID)), and a second stage evaluating the reproducibility of image statistics corresponding to domain-relevant radiomic features was developed. A summary measure was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, and to identify various artifacts. 58 submissions from 12 unique users were received for this Challenge. The top-ranked submission employed a conditional latent diffusion model, whereas the joint runners-up employed a generative adversarial network, followed by another network for image superresolution. We observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID-based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. This Grand Challenge highlighted the need for domain-specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
Simulation tools, first results and experimental status of the MURAVES experiment
Authors:
Andrea Giammanco,
Yanwen Hong,
Marwa Al Moussawi,
Fabio Ambrosino,
Antonio Anastasio,
Samip Basnet,
Lorenzo Bonechi,
Massimo Bongi,
Diletta Borselli,
Alan Bross,
Antonio Caputo,
Roberto Ciaranfi,
Luigi Cimmino,
Vitaliano Ciulli,
Raffaello D'Alessandro,
Mariaelena D'Errico,
Catalin Frosin,
Flora Giudicepietro,
Sandro Gonzi,
Giovanni Macedonio,
Vincenzo Masone,
Massimo Orazi,
Andrea Paccagnella,
Rosario Peluso,
Anna Pla-Dalmau
, et al. (7 additional authors not shown)
Abstract:
The MUon RAdiography of VESuvius (MURAVES) project aims at the study of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy, with the use of muons freely and abundantly produced by cosmic rays. In particular, the MURAVES experiment intends to perform muographic imaging of the internal structure of the summit of Mt. Vesuvius. The challenging measurement of the rock density distribution…
▽ More
The MUon RAdiography of VESuvius (MURAVES) project aims at the study of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy, with the use of muons freely and abundantly produced by cosmic rays. In particular, the MURAVES experiment intends to perform muographic imaging of the internal structure of the summit of Mt. Vesuvius. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help model possible eruption dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. This paper presents preliminary results from the analysis of the first data samples acquired with trackers pointing towards Mt. Vesuvius, including the first relative measurement of the density projection of two flanks of the volcano at three different altitudes; we also present the workflow of the simulation chain of the MURAVES experiment and its ongoing developments.
△ Less
Submitted 19 June, 2024; v1 submitted 22 November, 2023;
originally announced November 2023.
-
Spatiotemporal Image Reconstruction to Enable High-Frame Rate Dynamic Photoacoustic Tomography with Rotating-Gantry Volumetric Imagers
Authors:
Refik M. Cam,
Chao Wang,
Weylan Thompson,
Sergey A. Ermilov,
Mark A. Anastasio,
Umberto Villa
Abstract:
Significance: Dynamic photoacoustic computed tomography (PACT) is a valuable technique for monitoring physiological processes. However, current dynamic PACT techniques are often limited to 2D spatial imaging. While volumetric PACT imagers are commercially available, these systems typically employ a rotating gantry in which the tomographic data are sequentially acquired. Because the object varies d…
▽ More
Significance: Dynamic photoacoustic computed tomography (PACT) is a valuable technique for monitoring physiological processes. However, current dynamic PACT techniques are often limited to 2D spatial imaging. While volumetric PACT imagers are commercially available, these systems typically employ a rotating gantry in which the tomographic data are sequentially acquired. Because the object varies during the data-acquisition process, the sequential data-acquisition poses challenges to image reconstruction associated with data incompleteness. The proposed method is highly significant in that it will address these challenges and enable volumetric dynamic PACT imaging with existing imagers. Aim: The aim of this study is to develop a spatiotemporal image reconstruction (STIR) method for dynamic PACT that can be applied to commercially available volumetric PACT imagers that employ a sequential scanning strategy. The proposed method aims to overcome the challenges caused by the limited number of tomographic measurements acquired per frame. Approach: A low-rank matrix estimation-based STIR method (LRME-STIR) is proposed to enable dynamic volumetric PACT. The LRME-STIR method leverages the spatiotemporal redundancies to accurately reconstruct a 4D spatiotemporal image. Results: The numerical studies substantiate the LRME-STIR method's efficacy in reconstructing 4D dynamic images from measurements acquired with a rotating gantry. The experimental study demonstrates the method's ability to faithfully recover the flow of a contrast agent at a frame rate of 0.1 s even when only a single tomographic measurement per frame is available. Conclusions: The LRME-STIR method offers a promising solution to the challenges faced by enabling 4D dynamic imaging using commercially available volumetric imagers. By enabling accurate 4D reconstruction, this method has the potential to advance preclinical research.
△ Less
Submitted 30 September, 2023;
originally announced October 2023.
-
Learned Full Waveform Inversion Incorporating Task Information for Ultrasound Computed Tomography
Authors:
Luke Lozenski,
Hanchen Wang,
Fu Li,
Mark A. Anastasio,
Brendt Wohlberg,
Youzuo Lin,
Umberto Villa
Abstract:
Ultrasound computed tomography (USCT) is an emerging imaging modality that holds great promise for breast imaging. Full-waveform inversion (FWI)-based image reconstruction methods incorporate accurate wave physics to produce high spatial resolution quantitative images of speed of sound or other acoustic properties of the breast tissues from USCT measurement data. However, the high computational co…
▽ More
Ultrasound computed tomography (USCT) is an emerging imaging modality that holds great promise for breast imaging. Full-waveform inversion (FWI)-based image reconstruction methods incorporate accurate wave physics to produce high spatial resolution quantitative images of speed of sound or other acoustic properties of the breast tissues from USCT measurement data. However, the high computational cost of FWI reconstruction represents a significant burden for its widespread application in a clinical setting. The research reported here investigates the use of a convolutional neural network (CNN) to learn a map** from USCT waveform data to speed of sound estimates. The CNN was trained using a supervised approach with a task-informed loss function aiming at preserving features of the image that are relevant to the detection of lesions. A large set of anatomically and physiologically realistic numerical breast phantoms (NBPs) and corresponding simulated USCT measurements was employed during training. Once trained, the CNN can perform real-time FWI image reconstruction from USCT waveform data. The performance of the proposed method was assessed and compared against FWI using a hold-out sample of 41 NBPs and corresponding USCT data. Accuracy was measured using relative mean square error (RMSE), structural self-similarity index measure (SSIM), and lesion detection performance (DICE score). This numerical experiment demonstrates that a supervised learning model can achieve accuracy comparable to FWI in terms of RMSE and SSIM, and better performance in terms of task performance, while significantly reducing computational time.
△ Less
Submitted 30 August, 2023;
originally announced August 2023.
-
Super Phantoms: advanced models for testing medical imaging technologies
Authors:
Srirang Manohar,
Ioannis Sechopoulos,
Mark A. Anastasio,
Lena Maier-Hein,
Rajiv,
Gupta
Abstract:
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or…
▽ More
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or ex-vivo organs. Testing on these super phantoms, will enable iterative improvements well before in-vivo studies, fostering innovation. We illustrate super phantom examples, address development challenges, and envision centralized facilities supporting multiple institutions in applying these models for medical advancements.
△ Less
Submitted 8 April, 2024; v1 submitted 24 August, 2023;
originally announced August 2023.
-
A forward model incorporating elevation-focused transducer properties for 3D full-waveform inversion in ultrasound computed tomography
Authors:
Fu Li,
Umberto Villa,
Nebojsa Duric,
Mark A. Anastasio
Abstract:
Ultrasound computed tomography (USCT) is an emerging medical imaging modality that holds great promise for improving human health. Full-waveform inversion (FWI)-based image reconstruction methods account for the relevant wave physics to produce high spatial resolution images of the acoustic properties of the breast tissues. A practical USCT design employs a circular ring-array comprised of elevati…
▽ More
Ultrasound computed tomography (USCT) is an emerging medical imaging modality that holds great promise for improving human health. Full-waveform inversion (FWI)-based image reconstruction methods account for the relevant wave physics to produce high spatial resolution images of the acoustic properties of the breast tissues. A practical USCT design employs a circular ring-array comprised of elevation-focused ultrasonic transducers, and volumentric imaging is achieved by translating the ring-array orthogonally to the imaging plane. In commonly deployed slice-by-slice (SBS) reconstruction approaches, the three-dimensional (3D) volume is reconstructed by stacking together two-dimensional (2D) images reconstructed for each position of the ring-array. A limitation of the SBS reconstruction approach is that it does not account for 3D wave propagation physics and the focusing properties of the transducers, which can result in significant image artifacts and inaccuracies. To perform 3D image reconstruction when elevation-focused transducers are employed, a numerical description of the focusing properties of the transducers should be included in the forward model. To address this, a 3D computational model of an elevation-focused transducer is developed to enable 3D FWI-based reconstruction methods to be deployed in ring-array-based USCT. The focusing is achieved by applying a spatially varying temporal delay to the ultrasound pulse (emitter mode) and recorded signal (receiver mode). The proposed numerical transducer model is quantitatively validated and employed in computer-simulation studies that demonstrate its use in image reconstruction for ring-array USCT
△ Less
Submitted 14 September, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Investigating the robustness of a learning-based method for quantitative phase retrieval from propagation-based x-ray phase contrast measurements under laboratory conditions
Authors:
Rucha Deshpande,
Ashish Avachat,
Frank J. Brooks,
Mark A. Anastasio
Abstract:
Quantitative phase retrieval (QPR) in propagation-based x-ray phase contrast imaging of heterogeneous and structurally complicated objects is challenging under laboratory conditions due to partial spatial coherence and polychromaticity. A learning-based method (LBM) provides a non-linear approach to this problem while not being constrained by restrictive assumptions about object properties and bea…
▽ More
Quantitative phase retrieval (QPR) in propagation-based x-ray phase contrast imaging of heterogeneous and structurally complicated objects is challenging under laboratory conditions due to partial spatial coherence and polychromaticity. A learning-based method (LBM) provides a non-linear approach to this problem while not being constrained by restrictive assumptions about object properties and beam coherence. In this work, a LBM was assessed for its applicability under practical scenarios by evaluating its robustness and generalizability under typical experimental variations. Towards this end, an end-to-end LBM was employed for QPR under laboratory conditions and its robustness was investigated across various system and object conditions. The robustness of the method was tested via varying propagation distances and its generalizability with respect to object structure and experimental data was also tested. Although the LBM was stable under the studied variations, its successful deployment was found to be affected by choices pertaining to data pre-processing, network training considerations and system modeling. To our knowledge, we demonstrated for the first time, the potential applicability of an end-to-end learning-based quantitative phase retrieval method, trained on simulated data, to experimental propagation-based x-ray phase contrast measurements acquired under laboratory conditions. We considered conditions of polychromaticity, partial spatial coherence, and high noise levels, typical to laboratory conditions. This work further explored the robustness of this method to practical variations in propagation distances and object structure with the goal of assessing its potential for experimental use. Such an exploration of any LBM (irrespective of its network architecture) before practical deployment provides an understanding of its potential behavior under experimental settings.
△ Less
Submitted 2 November, 2022;
originally announced November 2022.
-
Assessing the ability of generative adversarial networks to learn canonical medical image statistics
Authors:
Varun A. Kelkar,
Dimitrios S. Gotsis,
Frank J. Brooks,
Prabhat KC,
Kyle J. Myers,
Rong** Zeng,
Mark A. Anastasio
Abstract:
In recent years, generative adversarial networks (GANs) have gained tremendous popularity for potential applications in medical imaging, such as medical image synthesis, restoration, reconstruction, translation, as well as objective image quality assessment. Despite the impressive progress in generating high-resolution, perceptually realistic images, it is not clear if modern GANs reliably learn t…
▽ More
In recent years, generative adversarial networks (GANs) have gained tremendous popularity for potential applications in medical imaging, such as medical image synthesis, restoration, reconstruction, translation, as well as objective image quality assessment. Despite the impressive progress in generating high-resolution, perceptually realistic images, it is not clear if modern GANs reliably learn the statistics that are meaningful to a downstream medical imaging application. In this work, the ability of a state-of-the-art GAN to learn the statistics of canonical stochastic image models (SIMs) that are relevant to objective assessment of image quality is investigated. It is shown that although the employed GAN successfully learned several basic first- and second-order statistics of the specific medical SIMs under consideration and generated images with high perceptual quality, it failed to correctly learn several per-image statistics pertinent to the these SIMs, highlighting the urgent need to assess medical image GANs in terms of objective measures of image quality.
△ Less
Submitted 26 April, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Evaluating Procedures for Establishing Generative Adversarial Network-based Stochastic Image Models in Medical Imaging
Authors:
Varun A. Kelkar,
Dimitrios S. Gotsis,
Frank J. Brooks,
Kyle J. Myers,
Prabhat KC,
Rong** Zeng,
Mark A. Anastasio
Abstract:
Modern generative models, such as generative adversarial networks (GANs), hold tremendous promise for several areas of medical imaging, such as unconditional medical image synthesis, image restoration, reconstruction and translation, and optimization of imaging systems. However, procedures for establishing stochastic image models (SIMs) using GANs remain generic and do not address specific issues…
▽ More
Modern generative models, such as generative adversarial networks (GANs), hold tremendous promise for several areas of medical imaging, such as unconditional medical image synthesis, image restoration, reconstruction and translation, and optimization of imaging systems. However, procedures for establishing stochastic image models (SIMs) using GANs remain generic and do not address specific issues relevant to medical imaging. In this work, canonical SIMs that simulate realistic vessels in angiography images are employed to evaluate procedures for establishing SIMs using GANs. The GAN-based SIM is compared to the canonical SIM based on its ability to reproduce those statistics that are meaningful to the particular medically realistic SIM considered. It is shown that evaluating GANs using classical metrics and medically relevant metrics may lead to different conclusions about the fidelity of the trained GANs. This work highlights the need for the development of objective metrics for evaluating GANs.
△ Less
Submitted 7 April, 2022;
originally announced April 2022.
-
The MURAVES experiment: study of the Vesuvius Great Cone with Muon Radiography
Authors:
M. D'Errico,
F. Ambrosino,
A. Anastasio,
S. Basnet,
L. Bonechi,
M. Bongi,
A. Bross,
R. Ciaranfi,
L. Cimmino,
C. Ciulli,
R. D'Alessandro,
A. Giammanco,
F. Giudicepietro,
S. Gonzi,
R. Karnam,
G. Macedonio,
V. Masone,
N. Mori,
M. Moussawi,
M. Orazi,
G. Passeggio,
R. Peluso,
A. Pla-Dalmau,
C. Rendon,
A. Samalan
, et al. (6 additional authors not shown)
Abstract:
The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techni…
▽ More
The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help the modeling of possible eruptive dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. Preliminary results from the analysis of a first data sample are presented.
△ Less
Submitted 24 February, 2022;
originally announced February 2022.
-
Prior image-based medical image reconstruction using a style-based generative adversarial network
Authors:
Varun A. Kelkar,
Mark A. Anastasio
Abstract:
Computed medical imaging systems require a computational reconstruction procedure for image formation. In order to recover a useful estimate of the object to-be-imaged when the recorded measurements are incomplete, prior knowledge about the nature of object must be utilized. In order to improve the conditioning of an ill-posed imaging inverse problem, deep learning approaches are being actively in…
▽ More
Computed medical imaging systems require a computational reconstruction procedure for image formation. In order to recover a useful estimate of the object to-be-imaged when the recorded measurements are incomplete, prior knowledge about the nature of object must be utilized. In order to improve the conditioning of an ill-posed imaging inverse problem, deep learning approaches are being actively investigated for better representing object priors and constraints. This work proposes to use a style-based generative adversarial network (StyleGAN) to constrain an image reconstruction problem in the case where additional information in the form of a prior image of the sought-after object is available. An optimization problem is formulated in the intermediate latent-space of a StyleGAN, that is disentangled with respect to meaningful image attributes or "styles", such as the contrast used in magnetic resonance imaging (MRI). Discrepancy between the sought-after and prior images is measured in the disentangled latent-space, and is used to regularize the inverse problem in the form of constraints on specific styles of the disentangled latent-space. A stylized numerical study inspired by MR imaging is designed, where the sought-after and the prior image are structurally similar, but belong to different contrast mechanisms. The presented numerical studies demonstrate the superiority of the proposed approach as compared to classical approaches in the form of traditional metrics.
△ Less
Submitted 17 February, 2022;
originally announced February 2022.
-
Impact of deep learning-based image super-resolution on binary signal detection
Authors:
Xiaohui Zhang,
Varun A. Kelkar,
Jason Granstedt,
Hua Li,
Mark A. Anastasio
Abstract:
Deep learning-based image super-resolution (DL-SR) has shown great promise in medical imaging applications. To date, most of the proposed methods for DL-SR have only been assessed by use of traditional measures of image quality (IQ) that are commonly employed in the field of computer vision. However, the impact of these methods on objective measures of image quality that are relevant to medical im…
▽ More
Deep learning-based image super-resolution (DL-SR) has shown great promise in medical imaging applications. To date, most of the proposed methods for DL-SR have only been assessed by use of traditional measures of image quality (IQ) that are commonly employed in the field of computer vision. However, the impact of these methods on objective measures of image quality that are relevant to medical imaging tasks remains largely unexplored. In this study, we investigate the impact of DL-SR methods on binary signal detection performance. Two popular DL-SR methods, the super-resolution convolutional neural network (SRCNN) and the super-resolution generative adversarial network (SRGAN), were trained by use of simulated medical image data. Binary signal-known-exactly with background-known-statistically (SKE/BKS) and signal-known-statistically with background-known-statistically (SKS/BKS) detection tasks were formulated. Numerical observers, which included a neural network-approximated ideal observer and common linear numerical observers, were employed to assess the impact of DL-SR on task performance. The impact of the complexity of the DL-SR network architectures on task-performance was quantified. In addition, the utility of DL-SR for improving the task-performance of sub-optimal observers was investigated. Our numerical experiments confirmed that, as expected, DL-SR could improve traditional measures of IQ. However, for many of the study designs considered, the DL-SR methods provided little or no improvement in task performance and could even degrade it. It was observed that DL-SR could improve the task-performance of sub-optimal observers under certain conditions. The presented study highlights the urgent need for the objective assessment of DL-SR methods and suggests avenues for improving their efficacy in medical imaging applications.
△ Less
Submitted 5 July, 2021;
originally announced July 2021.
-
3-D Stochastic Numerical Breast Phantoms for Enabling Virtual Imaging Trials of Ultrasound Computed Tomography
Authors:
Fu Li,
Umberto Villa,
Seonyeong Park,
Mark A. Anastasio
Abstract:
Ultrasound computed tomography (USCT) is an emerging imaging modality for breast imaging that can produce quantitative images that depict the acoustic properties of tissues. Computer-simulation studies, also known as virtual imaging trials, provide researchers with an economical and convenient route to systematically explore imaging system designs and image reconstruction methods. When simulating…
▽ More
Ultrasound computed tomography (USCT) is an emerging imaging modality for breast imaging that can produce quantitative images that depict the acoustic properties of tissues. Computer-simulation studies, also known as virtual imaging trials, provide researchers with an economical and convenient route to systematically explore imaging system designs and image reconstruction methods. When simulating an imaging technology intended for clinical use, it is essential to employ realistic numerical phantoms that can facilitate the objective, or task-based, assessment of image quality. Moreover, when computing objective image quality measures, an ensemble of such phantoms should be employed that display the variability in anatomy and object properties that is representative of the to-be-imaged patient cohort. Such stochastic phantoms for clinically relevant applications of USCT are currently lacking. In this work, a methodology for producing realistic three-dimensional (3D) numerical breast phantoms for enabling clinically relevant computer-simulation studies of USCT breast imaging is presented. By extending and adapting an existing stochastic 3D breast phantom for use withUSCT, methods for creating ensembles of numerical acoustic breast phantoms are established. These breast phantoms will possess clinically relevant variations in breast size, composition, acoustic properties, tumor locations, and tissue textures. To demonstrate the use of the phantoms in virtual USCT studies, two brief case studies are presented that address the development and assessment of image reconstruction procedures. Examples of breast phantoms produced by use of the proposed methods and a collection of 52 sets of simulated USCT measurement data have been made open source for use in image reconstruction development
△ Less
Submitted 22 June, 2022; v1 submitted 4 June, 2021;
originally announced June 2021.
-
A signal detection model for quantifying over-regularization in non-linear image reconstruction
Authors:
Emil Y. Sidky,
John Paul Phillips,
Weimin Zhou,
Greg Ongie,
Juan Cruz-Bastida,
Ingrid S. Reiser,
Mark A. Anastasio,
Xiaochuan Pan
Abstract:
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regu…
▽ More
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.
△ Less
Submitted 8 December, 2020; v1 submitted 7 October, 2020;
originally announced October 2020.
-
A survey of computational frameworks for solving the acoustic inverse problem in three-dimensional photoacoustic computed tomography
Authors:
Joemini Poudel,
Yang Lou,
Mark A. Anastasio
Abstract:
Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging technique that holds great promise for biomedical imaging. PACT is a hybrid imaging method that can exploit the strong endogenous contrast of optical methods along with the high spatial resolution of ultrasound methods. In its canonical form that is addressed in this article, PACT seeks to estim…
▽ More
Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging technique that holds great promise for biomedical imaging. PACT is a hybrid imaging method that can exploit the strong endogenous contrast of optical methods along with the high spatial resolution of ultrasound methods. In its canonical form that is addressed in this article, PACT seeks to estimate the photoacoustically-induced initial pressure distribution within the object. Image reconstruction methods are employed to solve the acoustic inverse problem associated with the image formation process. When an idealized imaging scenario is considered, analytic solutions to the PACT inverse problem are available; however, in practice, numerous challenges exist that are more readily addressed within an optimization-based, or iterative, image reconstruction framework. In this article, the PACT image reconstruction problem is reviewed within the context of modern optimization-based image reconstruction methodologies. Imaging models that relate the measured photoacoustic wavefields to the sought-after object function are described in their continuous and discrete forms. The basic principles of optimization-based image reconstruction from discrete PACT measurement data are presented, which includes a review of methods for modeling the PACT measurement system response and other important physical factors. Non-conventional formulations of the PACT image reconstruction problem, in which acoustic parameters of the medium are concurrently estimated along with the PACT image, are also introduced and reviewed.
△ Less
Submitted 9 May, 2019;
originally announced May 2019.
-
First Point-Spread Function and X-Ray Phase-Contrast Imaging Results With an 88-mm Diameter Single Crystal
Authors:
A. H. Lumpkin,
A. B. Garson,
M. A. Anastasio
Abstract:
In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystal…
▽ More
In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase contrast imaging data are quantified and presented.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
The Monitoring System of the End-Cap Calorimeter in the Belle II experiment
Authors:
V. Izzo,
A. Aloisio,
F. Ameli,
A. Anastasio,
P. Branchini,
F. Di Capua,
R. Giordano,
A. Kuzmin,
K. Miyabayashi,
I. Nakamura,
M. Nakao,
G. Tortone,
S. Uehara
Abstract:
The Belle II experiment is presently in phase-2 operation at the SuperKEKB electron-positron collider in KEK (Tsukuba, Japan). The detector is an upgrade of the Belle experiment at the KEKB collider and it is optimized for the study of rare B decays, being also sensitive to signals of New Physics beyond the Standard Model. The Electromagnetic Calorimeter (ECL) is based on CsI(Tl) scintillation cry…
▽ More
The Belle II experiment is presently in phase-2 operation at the SuperKEKB electron-positron collider in KEK (Tsukuba, Japan). The detector is an upgrade of the Belle experiment at the KEKB collider and it is optimized for the study of rare B decays, being also sensitive to signals of New Physics beyond the Standard Model. The Electromagnetic Calorimeter (ECL) is based on CsI(Tl) scintillation crystals. It splits in a barrel and two annular end-cap regions, these latter named Forward and Backward, according to the asymmetric design of the collider. CsI(Tl) crystals deliver a high light output at an affordable cost, however their yield changes with temperature and can be permanently damaged by humidity, due to the strong chemical affinity for moisture. Each ECL region is then equipped with thermistors and humidity probes to monitor environmental data. While sensors and cabling have been inherited from the original Belle design, the ECL monitoring system has been fully redesigned. In this paper, we present hardware and software architecture deployed for the 2112 CsI(Tl) crystals arranged in the Forward and Backward end-caps. Single-Board Computers (SBCs) have been designed ad-hoc for embedded applications. For sensor read-out, a data-acquisition system based on 24-bit ADCs with local processing capability has been realized and interfaced with the SBCs. EPICS applications send data across the Local Area Network for remote control and display.
△ Less
Submitted 1 July, 2018;
originally announced July 2018.
-
From Relativistic Electrons To X-Ray Phase Contrast Imaging
Authors:
A. H. Lumpkin,
A. B. Garson,
M. A. Anastasio
Abstract:
We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the referen…
▽ More
We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphor's 80-μm value. Potential fiber-optic plate depth-of-focus aspects and 33-μm diameter carbon fiber imaging are also addressed.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.
-
A forward-adjoint operator pair based on the elastic wave equation for use in transcranial photoacoustic tomography
Authors:
Kenji Mitsuhashi,
Joemini Poudel,
Thomas P. Matthews,
Alejandro Garcia-Uribe,
Lihong V. Wang,
Mark A. Anastasio
Abstract:
Photoacoustic computed tomography (PACT) is an emerging imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the photoacoustically induced initial pressure distribution within tissue. The PACT reconstruction problem corresponds to an inverse source problem in which the initial pressure distribution is recovered from measurements of the radiated wave…
▽ More
Photoacoustic computed tomography (PACT) is an emerging imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the photoacoustically induced initial pressure distribution within tissue. The PACT reconstruction problem corresponds to an inverse source problem in which the initial pressure distribution is recovered from measurements of the radiated wavefield.
A major challenge in transcranial PACT brain imaging is compensation for aberrations in the measured data due to the presence of the skull. Ultrasonic waves undergo absorption, scattering and longitudinal-to-shear wave mode conversion as they propagate through the skull. To properly account for these effects, a wave-equation-based inversion method should be employed that can model the heterogeneous elastic properties of the skull. In this work, a forward model based on a finite-difference time-domain discretization of the three-dimensional elastic wave equation is established and a procedure for computing the corresponding adjoint of the forward operator is presented. Massively parallel implementations of these operators employing multiple graphics processing units (GPUs) are also developed. The developed numerical framework is validated and investigated in computer-simulation and experimental phantom studies whose designs are motivated by transcranial PACT applications.
△ Less
Submitted 8 September, 2017;
originally announced September 2017.
-
Mitigation of artifacts due to isolated acoustic heterogeneities in photoacoustic computed tomography using a variable data truncation-based reconstruction method
Authors:
Joemini Poudel,
Thomas P. Matthews,
Lei Li,
Mark A. Anastasio,
Lihong V. Wang
Abstract:
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object possesses spatially variant acoustic properties that are unaccounted for by the reconstruction method, the estimated image can contain distortions. While reconstruction…
▽ More
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object possesses spatially variant acoustic properties that are unaccounted for by the reconstruction method, the estimated image can contain distortions. While reconstruction methods have recently been developed to compensate for this effect, they generally require the object's acoustic properties to be known a priori. To circumvent the need for detailed information regarding an object's acoustic properties, we previously proposed a half-time reconstruction method for PACT. A half-time reconstruction method estimates the PACT image from a data set that has been temporally truncated to exclude the data components that have been strongly aberrated. However, this method can be improved upon when the approximate sizes and locations of isolated heterogeneous structures, such as bones or gas pockets, are known. To address this, we investigate PACT reconstruction methods that are based on a variable data truncation (VDT) approach. The VDT approach represents a generalization of the half-time approach, in which the degree of temporal truncation for each measurement is determined by the distance between the corresponding ultrasonic transducer location and the nearest known bone or gas void location. Computer-simulated and experimental data are employed to demonstrate the effectiveness of the approach in mitigating artifacts due to acoustic heterogeneities.
△ Less
Submitted 7 September, 2017; v1 submitted 28 August, 2017;
originally announced August 2017.
-
Regularized Dual Averaging Image Reconstruction for Full-Wave Ultrasound Computed Tomography
Authors:
Thomas P. Matthews,
Kun Wang,
Cui** Li,
Neb Duric,
Mark A. Anastasio
Abstract:
Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are computationally demanding. Recently, a source encoding technique was combined with stochastic gradient descent to greatly reduce image reconstruction times. Howe…
▽ More
Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are computationally demanding. Recently, a source encoding technique was combined with stochastic gradient descent to greatly reduce image reconstruction times. However, this method bundles the stochastic data fidelity term with the deterministic regularization term. This limitation can be overcome by replacing stochastic gradient descent (SGD) with a structured optimization method, such as the regularized dual averaging (RDA) method, that exploits knowledge of the composition of the cost function. In this work, the dual averaging method is combined with source encoding techniques to improve the effectiveness of regularization while maintaining the reduced reconstruction times afforded by source encoding. It is demonstrated that each iteration can be decomposed into a gradient descent step based on the data fidelity term and a proximal update step corresponding to the regularization term. Furthermore, the regularization term is never explicitly differentiated, allowing non-smooth regularization penalties to be naturally incorporated. The wave equation is solved by use of a time-domain method. The effectiveness of this approach is demonstrated through computer-simulation and experimental studies. The results suggest that the dual averaging method can produce images with less noise and comparable resolution to those obtained by use of stochastic gradient descent.
△ Less
Submitted 23 August, 2017;
originally announced August 2017.
-
Impact of non-stationary optical illumination on image reconstruction in optoacoustic tomography
Authors:
Yang Lou,
Kun Wang,
Alexander. A. Oraevsky,
Mark. A. Anastasio
Abstract:
Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to illuminate the tissue of interest and acoustic signals are produced via the photoacoustic effect. From these data, an estimate of the distribution of the absorbed opti…
▽ More
Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to illuminate the tissue of interest and acoustic signals are produced via the photoacoustic effect. From these data, an estimate of the distribution of the absorbed optical energy density within the tissue is reconstructed, referred to as the object function. This quantity is defined, in part, by the distribution of light fluence within the tissue that is established by the laser source. When performing three-dimensional imaging of large objects, such as a female human breast, it can be difficult to achieve a relatively uniform coverage of light fluence within the volume of interest when the position of the laser source is fixed. To circumvent this, researchers have proposed illumination schemes in which the relative position of the laser source and ultrasound probe is fixed, and both are rotated together to acquire a tomographic data set. A problem with this rotating-illumination scheme is that the tomographic data are inconsistent; namely, the acoustic data recorded at each tomographic view angle (i.e., probe position) are produced by a distinct object function. In this work, the impact of this data inconsistency on image reconstruction accuracy is investigated systematically. This is accomplished by use of computer-simulation studies and application of mathematical results from the theory of microlocal analysis. These studies specify the set of image discontinuities that can be stably reconstructed with a non-stationary optical illumination set-up. The study also includes a comparison of the ability of iterative and analytic image reconstruction methods to mitigate artifacts attributable to the data inconsistency.
△ Less
Submitted 26 September, 2016;
originally announced September 2016.
-
The GAP-TPC
Authors:
B. Rossi,
A. Anastasio,
A. Boiano,
S. Catalanotti,
A. G. Cocco,
G. Covone,
P. Di Meo,
G. Longo,
A. Vanzanella,
S. Walker,
H. Wang,
Y. Wang,
G. Fiorillo
Abstract:
Several experiments have been conducted worldwide, with the goal of observing low-energy nuclear recoils induced by WIMPs scattering off target nuclei in ultra-sensitive, low-background detectors. In the last few decades noble liquid detectors designed to search for dark matter in the form of WIMPs have been extremely successful in improving their sensitivities and setting the best limits. One of…
▽ More
Several experiments have been conducted worldwide, with the goal of observing low-energy nuclear recoils induced by WIMPs scattering off target nuclei in ultra-sensitive, low-background detectors. In the last few decades noble liquid detectors designed to search for dark matter in the form of WIMPs have been extremely successful in improving their sensitivities and setting the best limits. One of the crucial problems to be faced for the development of large size (multi ton-scale) liquid argon experiments is the lack of reliable and low background cryogenic PMTs: their intrinsic radioactivity, cost, and borderline performance at 87 K rule them out as a possible candidate for photosensors. We propose a brand new concept of liquid argon-based detector for direct dark matter search: the Geiger-mode Avalanche Photodiode Time Projection Chamber (GAP-TPC) optimized in terms of residual radioactivity of the photosensors, energy and spatial resolution, light and charge collection efficiency
△ Less
Submitted 6 January, 2016; v1 submitted 5 January, 2016;
originally announced January 2016.
-
Joint Reconstruction of Absorbed Optical Energy Density and Sound Speed Distribution in Photoacoustic Computed Tomography: A numerical Investigation
Authors:
Chao Huang,
Kun Wang,
Robert W. Schoonover,
Lihong V. Wang,
Mark A. Anastasio
Abstract:
Photoacoustic computed tomography (PACT) is a rapidly emerging bioimaging modality that seeks to reconstruct an estimate of the absorbed optical energy density within an object. Conventional PACT image reconstruction methods assume a constant speed-of-sound (SOS), which can result in image artifacts when acoustic aberrations are significant. It has been demonstrated that incorporating knowledge of…
▽ More
Photoacoustic computed tomography (PACT) is a rapidly emerging bioimaging modality that seeks to reconstruct an estimate of the absorbed optical energy density within an object. Conventional PACT image reconstruction methods assume a constant speed-of-sound (SOS), which can result in image artifacts when acoustic aberrations are significant. It has been demonstrated that incorporating knowledge of an object's SOS distribution into a PACT image reconstruction method can improve image quality. However, in many cases, the SOS distribution cannot be accurately and/or conveniently estimated prior to the PACT experiment. Because variations in the SOS distribution induce aberrations in the measured photoacoustic wavefields, certain information regarding an object's SOS distribution is encoded in the PACT measurement data. Based on this observation, a joint reconstruction (JR) problem has been proposed in which the SOS distribution is concurrently estimated along with the sought-after absorbed optical energy density from the photoacoustic measurement data. A broad understanding of the extent to which the JR problem can be accurately and reliably solved has not been reported. In this work, a series of numerical experiments is described that elucidate some important properties of the JR problem that pertain to its practical feasibility. To accomplish this, an optimization-based formulation of the JR problem is developed that yields a non-linear iterative algorithm that alternatingly updates the two image estimates. Heuristic analytic insights into the reconstruction problem are also provided. These results confirm the ill-conditioned nature of the joint reconstruction problem that will present significant challenges for practical applications.
△ Less
Submitted 4 August, 2015;
originally announced August 2015.
-
A constrained variable projection reconstruction method for photoacoustic computed tomography without accurate knowledge of transducer responses
Authors:
Qiwei Sheng,
Kun Wang,
Thomas P. Matthews,
Jun Xia,
Liren Zhu,
Lihong V. Wang,
Mark A. Anastasio
Abstract:
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse resp…
▽ More
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse responses (EIRs) during the measurement process. If unaccounted for, this can degrade the accuracy of the reconstructed image. In principle, the effect of the EIRs on the measured PA signals can be ameliorated via deconvolution; images can be reconstructed subsequently by application of a reconstruction method that assumes an idealized EIR. Alternatively, the effect of the EIR can be incorporated into an imaging model and implicitly compensated for during reconstruction. In either case, the efficacy of the correction can be limited by errors in the assumed EIRs. In this work, a joint optimization approach to PACT image reconstruction is proposed for mitigating errors in reconstructed images that are caused by use of an inaccurate EIR. The method exploits the bi-linear nature of the imaging model and seeks to refine the measured EIR during the process of reconstructing the sought-after absorbed optical energy density. Computer-simulation and experimental studies are conducted to investigate the numerical properties of the method and demonstrate its value for mitigating image distortions and enhancing the visibility of fine structures.
△ Less
Submitted 27 May, 2015;
originally announced May 2015.
-
Waveform Inversion with Source Encoding for Breast Sound Speed Reconstruction in Ultrasound Computed Tomography
Authors:
Kun Wang,
Thomas Matthews,
Fatima Anis,
Cui** Li,
Neb Duric,
Mark A. Anastasio
Abstract:
Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding…
▽ More
Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer-simulation and experimental phantom studies are conducted to demonstrate the use of the WISE method. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.
△ Less
Submitted 30 December, 2014;
originally announced January 2015.
-
Discrete Imaging Models for Three-Dimensional Optoacoustic Tomography using Radially Symmetric Expansion Functions
Authors:
Kun Wang,
Robert W Schoonover,
Richard Su,
Alexander Oraevsky,
Mark A Anastasio
Abstract:
Optoacoustic tomography (OAT), also known as photoacoustic tomography, is an emerging computed biomedical imaging modality that exploits optical contrast and ultrasonic detection principles. Iterative image reconstruction algorithms that are based on discrete imaging models are actively being developed for OAT due to their ability to improve image quality by incorporating accurate models of the im…
▽ More
Optoacoustic tomography (OAT), also known as photoacoustic tomography, is an emerging computed biomedical imaging modality that exploits optical contrast and ultrasonic detection principles. Iterative image reconstruction algorithms that are based on discrete imaging models are actively being developed for OAT due to their ability to improve image quality by incorporating accurate models of the imaging physics, instrument response, and measurement noise. In this work, we investigate the use of discrete imaging models based on Kaiser-Bessel window functions for iterative image reconstruction in OAT. A closed-form expression for the pressure produced by a Kaiser-Bessel function is calculated, which facilitates accurate computation of the system matrix. Computer-simulation and experimental studies are employed to demonstrate the potential advantages of Kaiser-Bessel function-based iterative image reconstruction in OAT.
△ Less
Submitted 8 May, 2014; v1 submitted 3 October, 2013;
originally announced October 2013.
-
Accelerating Image Reconstruction in Three-Dimensional Optoacoustic Tomography on Graphics Processing Units
Authors:
Kun Wang,
Chao Huang,
Yu-Jiun Kao,
Cheng-Ying Chou,
Alexander A. Oraevsky,
Mark A. Anastasio
Abstract:
Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programmi…
▽ More
Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programming techniques.
Methods: Parallelization strategies are proposed to accelerate a filtered backprojection (FBP) algorithm and two different pairs of projection/backprojection operations that correspond to two different numerical imaging models. The algorithms are designed to fully exploit the parallel computing power of graphic processing units (GPUs). In order to evaluate the parallelization strategies for the projection/backprojection pairs, an iterative image reconstruction algorithm is implemented. Computer-simulation and experimental studies are conducted to investigate the computational efficiency and numerical accuracy of the developed algorithms.
Results: The GPU implementations improve the computational efficiency by factors of 1, 000, 125, and 250 for the FBP algorithm and the two pairs of projection/backprojection operators, respectively. Accurate images are reconstructed by use of the FBP and iterative image reconstruction algorithms from both computer-simulated and experimental data.
Conclusions: Parallelization strategies for 3D OAT image reconstruction are proposed for the first time. These GPU-based implementations significantly reduce the computational time for 3D image reconstruction, complementing our earlier work on 3D OAT iterative image reconstruction.
△ Less
Submitted 7 April, 2013;
originally announced April 2013.
-
Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography with Acoustically Inhomogeneous Media
Authors:
Chao Huang,
Kun Wang,
Liming Nie,
Lihong V. Wang,
Mark A. Anastasio
Abstract:
Existing approaches to image reconstruction in photoacoustic computed tomography (PACT) with acoustically heterogeneous media are limited to weakly varying media, are computationally burdensome, and/or cannot effectively mitigate the effects of measurement data incompleteness and noise. In this work, we develop and investigate a discrete imaging model for PACT that is based on the exact photoacous…
▽ More
Existing approaches to image reconstruction in photoacoustic computed tomography (PACT) with acoustically heterogeneous media are limited to weakly varying media, are computationally burdensome, and/or cannot effectively mitigate the effects of measurement data incompleteness and noise. In this work, we develop and investigate a discrete imaging model for PACT that is based on the exact photoacoustic (PA) wave equation and facilitates the circumvention of these limitations. A key contribution of the work is the establishment of a procedure to implement a matched forward and backprojection operator pair associated with the discrete imaging model, which permits application of a wide-range of modern image reconstruction algorithms that can mitigate the effects of data incompleteness and noise. The forward and backprojection operators are based on the k-space pseudospectral method for computing numerical solutions to the PA wave equation in the time domain. The developed reconstruction methodology is investigated by use of both computer-simulated and experimental PACT measurement data.
△ Less
Submitted 22 March, 2013;
originally announced March 2013.
-
A simple Fourier transform-based reconstruction formula for photoacoustic computed tomography with a circular or spherical measurement geometry
Authors:
Kun Wang,
Mark A. Anastasio
Abstract:
Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging modality that has great potential for a wide range of biomedical imaging applications. In this Note, we derive a hybrid reconstruction formula that is mathematically exact and operates on a data function that is expressed in the temporal frequency and spatial domains. This formula explicitly rev…
▽ More
Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging modality that has great potential for a wide range of biomedical imaging applications. In this Note, we derive a hybrid reconstruction formula that is mathematically exact and operates on a data function that is expressed in the temporal frequency and spatial domains. This formula explicitly reveals new insights into how the spatial frequency components of the sought-after object function are determined by the temporal frequency components of the data function measured with a circular or spherical measurement geometry in two- and three-dimensional implementations of PACT, respectively. The structure of the reconstruction formula is surprisingly simple compared with existing Fourier-domain reconstruction formulae. It also yields a straightforward numerical implementation that is robust and two orders of magnitude more computationally efficient than filtered backprojection algorithms.
△ Less
Submitted 4 October, 2012; v1 submitted 10 August, 2012;
originally announced August 2012.
-
Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography
Authors:
Kun wang,
Richard Su,
Alexander A. Oraevsky,
Mark A. Anastasio
Abstract:
Iterative image reconstruction algorithms for optoacoustic tomography (OAT), also known as photoacoustic tomography, have the ability to improve image quality over analytic algorithms due to their ability to incorporate accurate models of the imaging physics, instrument response, and measurement noise. However, to date, there have been few reported attempts to employ advanced iterative image recon…
▽ More
Iterative image reconstruction algorithms for optoacoustic tomography (OAT), also known as photoacoustic tomography, have the ability to improve image quality over analytic algorithms due to their ability to incorporate accurate models of the imaging physics, instrument response, and measurement noise. However, to date, there have been few reported attempts to employ advanced iterative image reconstruction algorithms for improving image quality in three-dimensional (3D) OAT. In this work, we implement and investigate two iterative image reconstruction methods for use with a 3D OAT small animal imager: namely, a penalized least-squares (PLS) method employing a quadratic smoothness penalty and a PLS method employing a total variation norm penalty. The reconstruction algorithms employ accurate models of the ultrasonic transducer impulse responses. Experimental data sets are employed to compare the performances of the iterative reconstruction algorithms to that of a 3D filtered backprojection (FBP) algorithm. By use of quantitative measures of image quality, we demonstrate that the iterative reconstruction algorithms can mitigate image artifacts and preserve spatial resolution more effectively than FBP algorithms. These features suggest that the use of advanced image reconstruction algorithms can improve the effectiveness of 3D OAT while reducing the amount of data required for biomedical applications.
△ Less
Submitted 15 July, 2012; v1 submitted 4 July, 2012;
originally announced July 2012.