Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC
Authors:
Nir Amram,
Gideon Bella,
Yan Benhammou,
Marco A. Diaz,
Ehud Duchovni,
Erez Etzion,
Alon Hershenhorn,
Amit Klier,
Nachman Lupu,
Giora Mikenberg,
Dmitry Milstein,
Yonathan Munwes,
Osamu Sasaki,
Meir Shoa,
Vladimir Smakhtin,
Ulrich Volkmann
Abstract:
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strip…
▽ More
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strips and wires readout, with a total thickness of 50 mm, have been constructed. Their local spatial resolution has been measured in a 100 GeV/c muon test beam at CERN. At perpendicular incidence angle, single gap position resolution better than 60 microns has been obtained. For incidence angle of 20 degrees resolution of less than 100 micron was achieved. TGC prototypes were also tested under a flux of 10^5 Hz/cm^2 of 5.5-6.5 MeV neutrons, showing a high efficiency for cosmic muons detection.
△ Less
Submitted 2 June, 2010; v1 submitted 1 June, 2010;
originally announced June 2010.
-
The use of cluster quality for track fitting in the CSC detector
Authors:
Erez Etzion,
David Primor,
Giora Mikenberg,
Nir Amram,
Hagit Messer
Abstract:
The new particle accelerators and its experiments create a challenging data processing environment, characterized by large amount of data where only small portion of it carry the expected new scientific information. Modern detectors, such as the Cathode Strip Chamber (CSC), achieve high accuracy of coordinate measurements (between 50 to 70 microns). However, heavy physical backgrounds can decrea…
▽ More
The new particle accelerators and its experiments create a challenging data processing environment, characterized by large amount of data where only small portion of it carry the expected new scientific information. Modern detectors, such as the Cathode Strip Chamber (CSC), achieve high accuracy of coordinate measurements (between 50 to 70 microns). However, heavy physical backgrounds can decrease the accuracy significantly. In the presence of such background, the charge induced over adjacent CSC strips (cluster) is different from the ideal Matheison distribution. The traditional least squares method which takes the same ideal position error for all clusters loses its optimal properties on contaminated data. A new technique that calculates the cluster quality and uses it to improve the track fitting results is suggested. The algorithm is applied on test beam data, and its performance is compared to other fitting methods. It is shown that the suggested algorithm improves the fitting performance significantly.
△ Less
Submitted 13 December, 2006;
originally announced December 2006.
-
The Cosmic Ray Hodoscopes for Testing Thin Gap Chambers at the Technion and Tel Aviv University
Authors:
E. Etzion,
H. Abramowicz,
N. Amram,
Y. Benhammou,
M. Ben-Moshe,
G. Bella,
J. Ginzburg,
Y. Gernitzky,
A. Harel,
H. Landsman,
N. Panikashvili,
Y. Rozen,
S. Tarem,
E. Warszawski,
J. Wasilewski,
L. Levinson
Abstract:
Thin gap chambers (TGCs) are built for the muon trigger chambers in the endcap region of the LHC experiment ATLAS. More than 2500 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Detailed testing of these chambers is performed at the Technion and at the Tel-Aviv University. Two cosmic ray hodoscopes for testing the operation of these detecto…
▽ More
Thin gap chambers (TGCs) are built for the muon trigger chambers in the endcap region of the LHC experiment ATLAS. More than 2500 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Detailed testing of these chambers is performed at the Technion and at the Tel-Aviv University. Two cosmic ray hodoscopes for testing the operation of these detectors were built in Israel. In these hodoscopes the response of the chambers to energetic cosmic ray muons is recorded and analyzed. The hodoscopes measure the exact time and space location of the cosmic ray hit and read out the chambers which are being tested to verify that they produce a corresponding signal within the required time interval. The cosmic ray hodoscopes built at the Technion and at the Tel Aviv University for the test of ATLAS TGCs are described. The mechanical structure, readout electronics, data acquisition and operating scheme are presented. Typical TGC test results are presented and discussed.
△ Less
Submitted 19 February, 2004; v1 submitted 11 December, 2003;
originally announced December 2003.