-
Results and Limits of Time Division Multiplexing for the BICEP Array High Frequency Receivers
Authors:
S. Fatigoni,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. J. Cukierman,
E. V. Denison,
M. I. Dierickx,
L. Duband,
M. Eiben,
J. P. Filippini,
A. Fortes,
M. Gao,
C. Giannakopoulos,
N. Goeckner-Wald,
D. C. Goldfinger
, et al. (62 additional authors not shown)
Abstract:
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the…
▽ More
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard Multi Channel Electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates Time Division Multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and crosstalk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Future experiments like CMB-S4 plan to use TES bolometers with Time Division/SQUID-based readout for an even larger number of detectors.
△ Less
Submitted 24 October, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Theoretical and real-time study of uniaxial nematic liquid crystal phase transitions using Fresnel diffraction
Authors:
N. Madadi,
M. Amiri
Abstract:
Liquid crystals (LCs) play a fundamental and significant role in modern technology. Recently, they have also been used in active switching, adaptive optics, and next-generation displays for augmented and virtual reality. This is due to the diverse properties of their various phases and the growing physical understanding of LCs. Our goal is to examine the applicability of a new method in determinin…
▽ More
Liquid crystals (LCs) play a fundamental and significant role in modern technology. Recently, they have also been used in active switching, adaptive optics, and next-generation displays for augmented and virtual reality. This is due to the diverse properties of their various phases and the growing physical understanding of LCs. Our goal is to examine the applicability of a new method in determining these quantities for thermotropic uniaxial nematic liquid crystals (NLCs), even though nearly all theoretical and experimental efforts are focused on a deeper understanding of the temperature-dependent free energy behavior and other quantities related to it, especially in the vicinity of the first- and second-order phase transitions of LCs. The method that is being discussed is based on Fresnel diffraction (FD) from phase objects, which has found a wide range of precise metrological applications over the past two decades. Diffractometry is a very sensitive, accurate, and immune technique that can convert any change in the order of LCs as a function of temperature into a change in the optical phase and, as a result, a recordable change in the visibility of the light diffraction pattern from phase steps. This contrasts with interferometry, which is very sensitive to environmental changes. Theoretical investigations, numerical calculations, and comparisons of the results with experimental observations in turn demonstrate very high compliance with the output of other existing methods. As we will see, this method has the potential to not only strengthen existing approaches by addressing some of their flaws and shortcomings but also to take its place next to them.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Authors:
C. Zhang,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
H. Boenish,
E. Bullock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
M. Dierickx,
L. Duband,
S. Fatigoni,
J. P. Filippini,
G. Hall,
M. Halpern,
S. Harrison,
S. Henderson,
S. R. Hildebrandt
, et al. (44 additional authors not shown)
Abstract:
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of grav…
▽ More
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
Effect of surface roughness on the Goos-Hänchen shift
Authors:
Z. Tahmasebi,
M. Amiri
Abstract:
By considering an optically denser medium with a flat surface, but with natural roughness instead of abstract geometrical boundary which leads to mathematical discontinuity on the boundary of two adjacent stratified media, we have thus established the importance of considering physical surfaces; and thus we studied the Goos-Hänchen (GH) effect by ray-optics description to shed light on parts of th…
▽ More
By considering an optically denser medium with a flat surface, but with natural roughness instead of abstract geometrical boundary which leads to mathematical discontinuity on the boundary of two adjacent stratified media, we have thus established the importance of considering physical surfaces; and thus we studied the Goos-Hänchen (GH) effect by ray-optics description to shed light on parts of this effect which have remained ambiguous. We replaced the very thin region of surface roughness by a continuous inhomogeneous intermediary medium. Applying Fermat's principle for the incident light ray, few fundamental questions about GH shift are more convincingly addressed which are in excellent agreement, even with the most details of the experimental results.
△ Less
Submitted 29 September, 2016;
originally announced September 2016.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
On Laplace-Runge-Lenz Vector as Symmetry Breaking order parameter in Kepler Orbit and Goldstone Boson
Authors:
Manouchehr Amiri
Abstract:
We introduce a type of symmetry breaking and associated order parameter in connection with Laplace-Runge-Lenz vector of Kepler orbit through an extended spatial dimension and Ensemble view. By implementation of a small extra spatial dimension and embedded infinitesimal toral manifold, it has been shown that emerging of LRL vector under SO(4)symmetry is in analogy with a variety of explicit and spo…
▽ More
We introduce a type of symmetry breaking and associated order parameter in connection with Laplace-Runge-Lenz vector of Kepler orbit through an extended spatial dimension and Ensemble view. By implementation of a small extra spatial dimension and embedded infinitesimal toral manifold, it has been shown that emerging of LRL vector under SO(4)symmetry is in analogy with a variety of explicit and spontaneous symmetry breaking situations and related Goldstone bosons such as phonons and spin waves. A theorem introduced to generalize this concept of breaking symmetry. The diffeomorphism of circular orbit(geodesic)to elliptic one proved to be equivalent with a covariant derivative and related parallel displacement in this extended four dimensional spatial space.Respect to ensemble definition this diffeomorphism breaks the O(2) symmetry of initial orbit and Hamiltonian to Z2 resulting in broken generators in quotient space and associated Goldstone boson as perturbing Hamiltonian term leading to a perpetual circular motion on 2-torus comparable to the perpetual motion idea in Time Crystal of Wilczek. This leads to an introduction of gravitational gauge potential under the symmetry of Cartan sub algebra of su(2).
△ Less
Submitted 11 April, 2014;
originally announced May 2014.
-
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell Telescope
Authors:
W. S. Holland,
D. Bintley,
E. L. Chapin,
A. Chrysostomou,
G. R. Davis,
J. T. Dempsey,
W. D. Duncan,
M. Fich,
P. Friberg,
M. Halpern,
K. D. Irwin,
T. Jenness,
B. D. Kelly,
M. J. MacIntosh,
E. I. Robson,
D. Scott,
P. A. R. Ade,
E. Atad-Ettedgui,
D. S. Berry,
S. C. Craig,
X. Gao,
A. G. Gibb,
G. C. Hilton,
M. I. Hollister,
J. B. Kycia
, et al. (24 additional authors not shown)
Abstract:
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 micro…
▽ More
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 microns, the vast increase in pixel count means that SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument. In this paper we present an overview of the instrument, discuss the physical characteristics of the superconducting detector arrays, outline the observing modes and data acquisition, and present the early performance figures on the telescope. We also showcase the capabilities of the instrument via some early examples of the science SCUBA-2 has already undertaken. In February 2012, SCUBA-2 began a series of unique legacy surveys for the JCMT community. These surveys will take 2.5 years and the results are already providing complementary data to the shorter wavelength, shallower, larger-area surveys from Herschel. The SCUBA-2 surveys will also provide a wealth of information for further study with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
△ Less
Submitted 16 January, 2013;
originally announced January 2013.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.