  1. arXiv:2007.11527  [pdf, other

    physics.med-ph

    Optical Hemodynamic Imaging of Jugular Venous Dynamics During Altered Central Venous Pressure

    Authors: Robert Amelard, Andrew D Robertson, Courtney A Patterson, Hannah Heigold, Essi Saarikoski, Richard L Hughson

    Abstract: An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible… ▽ More

    Submitted 24 March, 2021; v1 submitted 22 July, 2020; originally announced July 2020.

  2. arXiv:1907.05376  [pdf, other

    eess.IV cs.CV physics.med-ph

    Monocular 3D Sway Tracking for Assessing Postural Instability in Cerebral Hypoperfusion During Quiet Standing

    Authors: Robert Amelard, Kevin R Murray, Eric T Hedge, Taylor W Cleworth, Mamiko Noguchi, Andrew Laing, Richard L Hughson

    Abstract: Postural instability is prevalent in aging and neurodegenerative disease, decreasing quality of life and independence. Quantitatively monitoring balance control is important for assessing treatment efficacy and rehabilitation progress. However, existing technologies for assessing postural sway are complex and expensive, limiting their widespread utility. Here, we propose a monocular imaging system… ▽ More

    Submitted 5 November, 2019; v1 submitted 11 July, 2019; originally announced July 2019.

  3. A new take on measuring relative nutritional density: The feasibility of using a deep neural network to assess commercially-prepared pureed food concentrations

    Authors: Kaylen J. Pfisterer, Robert Amelard, Audrey G. Chung, Alexander Wong

    Abstract: Dysphagia affects 590 million people worldwide and increases risk for malnutrition. Pureed food may reduce choking, however preparation differences impact nutrient density making quality assurance necessary. This paper is the first study to investigate the feasibility of computational pureed food nutritional density analysis using an imaging system. Motivated by a theoretical optical dilution mode… ▽ More

    Submitted 3 November, 2017; v1 submitted 23 July, 2017; originally announced July 2017.

  4. arXiv:1606.09118  [pdf, other

    cs.CV physics.optics

    A spectral-spatial fusion model for robust blood pulse waveform extraction in photoplethysmographic imaging

    Authors: Robert Amelard, David A Clausi, Alexander Wong

    Abstract: Photoplethysmographic imaging is a camera-based solution for non-contact cardiovascular monitoring from a distance. This technology enables monitoring in situations where contact-based devices may be problematic or infeasible, such as ambulatory, sleep, and multi-individual monitoring. However, extracting the blood pulse waveform signal is challenging due to the unknown mixture of relevant (pulsat… ▽ More

    Submitted 29 June, 2016; originally announced June 2016.

    Comments: 10 pages, 6 figures

  5. arXiv:1604.05213  [pdf, other

    physics.med-ph cs.CV physics.optics

    Non-contact hemodynamic imaging reveals the jugular venous pulse waveform

    Authors: Robert Amelard, Richard L Hughson, Danielle K Greaves, Kaylen J Pfisterer, Jason Leung, David A Clausi, Alexander Wong

    Abstract: Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a novel light-based photoplethysmo… ▽ More

    Submitted 21 April, 2016; v1 submitted 15 April, 2016; originally announced April 2016.

    Comments: 10 pages, 8 figures

  6. arXiv:1503.06775  [pdf, other

    physics.optics cs.CV

    Non-contact transmittance photoplethysmographic imaging (PPGI) for long-distance cardiovascular monitoring

    Authors: Robert Amelard, Christian Scharfenberger, Farnoud Kazemzadeh, Kaylen J. Pfisterer, Bill S. Lin, Alexander Wong, David A. Clausi

    Abstract: Photoplethysmography (PPG) devices are widely used for monitoring cardiovascular function. However, these devices require skin contact, which restrict their use to at-rest short-term monitoring using single-point measurements. Photoplethysmographic imaging (PPGI) has been recently proposed as a non-contact monitoring alternative by measuring blood pulse signals across a spatial region of interest.… ▽ More

    Submitted 23 March, 2015; originally announced March 2015.

    Comments: 13 pages, 6 figures, submitted to Nature Scientific Reports, for associated video files see http://vip.uwaterloo.ca/publications/non-contact-transmittance-photoplethysmographic-imaging-ppgi-long-distance