Development of wide range photon detection system for muonic X-ray spectroscopy
Authors:
R. Mizuno,
M. Niikura,
T. Y. Saito,
T. Matsuzaki,
H. Sakurai,
A. Amato,
S. Asari,
S. Biswas,
I. Chiu,
L. Gerchow,
Z. Guguchia,
G. Janka,
K. Ninomiya,
N. Ritjoho,
A. Sato,
K. von Schoeler,
D. Tomono,
K. Terada,
C. Wang
Abstract:
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durabi…
▽ More
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durability are studied with standard $γ$-ray sources and in-beam experiment using $^{27}\mathrm{Al}(p, γ){}^{28}\mathrm{Si}$ resonance reaction. The detection system was demonstrated at Paul Scherrer Institute. A calibration method for a photon detector at a muon facility using muonic X-rays of $^{197}$Au and $^{209}$Bi is proposed.
△ Less
Submitted 18 December, 2023; v1 submitted 31 August, 2023;
originally announced September 2023.
-
Determination of compressive stress in thin films using micro-machined buckled membranes
Authors:
C. Malhaire,
M. Granata,
D. Hofman,
A. Amato,
V. Martinez,
G. Cagnoli,
A. Lemaitre,
N. Shcheblanov
Abstract:
In this work, optical profilometry and finite-element simulations are applied on buckled micro-machined membranes for the stress analysis of ion-beam-sputtered $\mathrm{Ta_{2}O_{5}}$ and $\mathrm{SiO_{2}}$ thin films. Layers with different thicknesses are grown on silicon substrates, then several membranes with different geometries are manufactured with standard micro-system technologies; due to a…
▽ More
In this work, optical profilometry and finite-element simulations are applied on buckled micro-machined membranes for the stress analysis of ion-beam-sputtered $\mathrm{Ta_{2}O_{5}}$ and $\mathrm{SiO_{2}}$ thin films. Layers with different thicknesses are grown on silicon substrates, then several membranes with different geometries are manufactured with standard micro-system technologies; due to a high level of the films' compressive stress, buckled membranes are obtained. Thermally-grown silica membranes are also produced, for comparison. The residual stress values are determined by comparing the measured and simulated deflections of the membranes. The average stress state of the $\mathrm{Ta_{2}O_{5}}$ thin films is found to be $-209$ MPa. The $\mathrm{SiO_{2}}$ thin films are in a higher compressive stress state whose average value is $-576$ MPa. The average stress in thermal $\mathrm{SiO_{2}}$ thin layers grown at 1130 $^{\circ}$C is found equal to $-321$ MPa, in good agreement with the literature.
△ Less
Submitted 25 May, 2023;
originally announced May 2023.
-
GermanIum Array for Non-destructive Testing (GIANT) setup for Muon Induced X-ray Emission (MIXE) at the Paul Scherrer Institute
Authors:
Lars Gerchow,
Sayani Biswas,
Gianluca Janka,
Carlos Vigo,
Andreas Knecht,
Stergiani Marina Vogiatzi,
Narongrit Ritjoho,
Thomas Prokscha,
Hubertus Luetkens,
Alex Amato
Abstract:
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most mu…
▽ More
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (S$μ$S). We report here the decision making, construction and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g. resolving down to 1 at% elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beamspots were characterized with a dedicated charged particle tracker to be 22.06$\pm$0.18 and 14.45$\pm$0.06 mm for 25 and 45 MeV/c, respectively. Advanced analysis of the High Purity Germanium (HPGe) signals further allows to improve energy and timing resolutions to ~1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of $\overline{ε_E}$ =0.11% and an energy resolution of $\overline{σ_E}$ = 0.8 keV at E=1000 keV. The overall performance of the GIANT setup at S$μ$S allowed to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with industry. Future improvements will include a simulation based analysis and a higher degree of automation, e.g. automatic scans of a series of muon momenta and automatic sample changing.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Effects of mixing and annealing on the optical and mechanical properties of TiO$_{2}$:Ta$_{2}$O$_{5}$ amorphous coatings
Authors:
Alex Amato,
Michele Magnozzi,
Nikita Shcheblanov,
Anaël Lemaître,
Gianpietro Cagnoli,
Massimo Granata,
Christophe Michel,
Gianluca Gemme,
Laurent Pinard,
Maurizio Canepa
Abstract:
Amorphous mixed titania-tantala coatings are key components of Bragg reflectors in the gravitational wave detectors (GWDs). Attaining the lowest possible values of optical absorption and mechanical losses in the coatings is of paramount importance for GWDs, and this requires a complex optimization of the coating deposition and post-deposition annealing. We present here a systematic investigation o…
▽ More
Amorphous mixed titania-tantala coatings are key components of Bragg reflectors in the gravitational wave detectors (GWDs). Attaining the lowest possible values of optical absorption and mechanical losses in the coatings is of paramount importance for GWDs, and this requires a complex optimization of the coating deposition and post-deposition annealing. We present here a systematic investigation of the optical properties and internal friction of amorphous mixed titania-tantala coatings grown by ion beam sputtering. We consider coatings with six different cation mixing ratios and we study them both in the as-deposited and annealed state. By exploiting spectroscopic ellipsometry data and modelling, along with ancillary techniques, we retrieved the dielectric function of the coatings in a wide spectral range. When varying the mixing ratio and performing the annealing we find monotonic trends for most of the aforementioned properties. Remakably, the post-annealing Urbach energy displays a definite minimum for a mixing ratio around 20%, very close to the composition of the coatings showing the lowest optical absorption for GWDs applications. We suggest that the observed minimum in the Urbach energy depends not only on the mixing ratio, but also on the annealing parameters. On the other hand, the minimum coating loss angle was found to be weakly dependent on the considered measurement frequency and to lie within a rather broad range of Ti content, suggesting that the search for an absolute minimum following post-deposition annealing should be rather sought in the study of the best annealing parameters for each specific cation ratio considered. This work constitutes a reference for the optical properties of the amorphous mixed titania-tantala coatings, and highlights the relevance of the Urbach energy in the optimization process of materials for high-performing Bragg reflectors.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
ETpathfinder: a cryogenic testbed for interferometric gravitational-wave detectors
Authors:
A. Utina,
A. Amato,
J. Arends,
C. Arina,
M. de Baar,
M. Baars,
P. Baer,
N. van Bakel,
W. Beaumont,
A. Bertolini,
M. van Beuzekom,
S. Biersteker,
A. Binetti,
H. J. M. ter Brake,
G. Bruno,
J. Bryant,
H. J. Bulten,
L. Busch,
P. Cebeci,
C. Collette,
S. Cooper,
R. Cornelissen,
P. Cuijpers,
M. van Dael,
S. Danilishin
, et al. (90 additional authors not shown)
Abstract:
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are req…
▽ More
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are required. ETpathfinder prototype uses full interferometer configurations and aims to provide a high sensitivity facility in a similar environment as ET. Along with the interferometry at 1550 nm and silicon test masses, ETpathfinder will focus on cryogenic technologies, lasers and optics at 2090 nm and advanced quantum-noise reduction schemes. This paper analyses the underpinning noise contributions and combines them into full noise budgets of the two initially targeted configurations: 1) operating with 1550 nm laser light and at a temperature of 18 K and 2) operating at 2090 nm wavelength and a temperature of 123 K.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Characterization of ion-beam-sputtered AlF$_3$ thin films for gravitational-wave interferometers
Authors:
M. Bischi,
A. Amato,
M. Bazzan,
G. Cagnoli,
M. Canepa,
G. Favaro,
D. Forest,
P. Gobbi,
M. Granata,
G. M. Guidi,
G. Maggioni,
F. Martelli,
M. Menotta,
M. Montani,
F. Piergiovanni,
L. Valentini
Abstract:
Thermal noise in amorphous coatings is a limitation for a wide range of precision experiments such as gravitational-wave detectors (GWDs). Mirrors for GWDs are composed of multiple thin layers of dielectric materials deposited on a substrate: the stack is made of layers with a high refractive index interleaved with layers of a low refractive index. The goal is to obtain high reflectivity and low t…
▽ More
Thermal noise in amorphous coatings is a limitation for a wide range of precision experiments such as gravitational-wave detectors (GWDs). Mirrors for GWDs are composed of multiple thin layers of dielectric materials deposited on a substrate: the stack is made of layers with a high refractive index interleaved with layers of a low refractive index. The goal is to obtain high reflectivity and low thermal noise. In this paper we report on the optical and mechanical properties of ion-beam-sputtered aluminium fluoride (AlF$_3$) thin films which have one of the lowest refractive index among the known coating materials and we discuss their application in current and future GWDs.
△ Less
Submitted 9 June, 2022;
originally announced June 2022.
-
Measurement and simulation of mechanical and optical properties of sputtered amorphous SiC coatings
Authors:
G. Favaro,
A. Amato,
F. Arciprete,
M. Bazzan,
E. Cesarini,
F. De Matteis,
T. H. Dao,
M. Granata,
C. Honrado-Benítez,
N. Gutiérrez-Luna,
J. I. Larruquert,
G. Lorenzin,
D. Lumaca,
G. Maggioni,
M. Magnozzi,
E. Placidi,
P. Prosposito,
F. Puosi
Abstract:
In this work We report on the extensive characterization of amorphous silicon carbide (a-SiC) coatings prepared by physical deposition methods. We compare the results obtained on two different sputtering systems (a standard RF magnetron sputtering and a ion-beam assisted sputtering) to seize the impact of two different setups on the repeatably of the results.
After a thorough characterization of…
▽ More
In this work We report on the extensive characterization of amorphous silicon carbide (a-SiC) coatings prepared by physical deposition methods. We compare the results obtained on two different sputtering systems (a standard RF magnetron sputtering and a ion-beam assisted sputtering) to seize the impact of two different setups on the repeatably of the results.
After a thorough characterization of structural, morphological, and compositional characteristics of the prepared samples, we focus on a detailed study of the optical and mechanical losses in those materials. Mechanical losses are further investigated from a microscopic point of view by comparing our experimental results with molecular dynamic simulations of the amorphous SiC structure: first we define a protocol to generate a numerical model of the amorphous film, capturing the main features of the real system; then we simulate its dynamical behaviour upon deformation in order to obtain its mechanical response. Our results are discussed within the perspective application of a-SiC as an optical material for high-precision optical experiments and in particular in gravitational wave interferometry.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique
Authors:
Sayani Biswas,
Lars Gerchow,
Hubertus Luetkens,
Thomas Prokscha,
Aldo Antognini,
Niklaus Berger,
Thomas Elias Cocolios,
Rugard Dressler,
Paul Indelicato,
Klaus Jungmann,
Klaus Kirch,
Andreas Knecht,
Angela Papa,
Randolf Pohl,
Maxim Pospelov,
Elisa Rapisarda,
Peter Reiter,
Narongrit Ritjoho,
Stephanie Roccia,
Nathal Severijns,
Alexander Skawran,
Stergiani Marina Vogiatzi,
Frederik Wauters,
Lorenz Willmann,
Alex Amato
Abstract:
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the avail…
▽ More
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Design of the ELIMAIA ion collection system
Authors:
F. Schillaci,
G. A. P. Cirrone,
G. Cuttone,
M. Maggiore,
L. Ando,
A. Amato,
M. Costa,
G. Gallo,
G. Korn,
G. Larosa,
R. Leanza,
R. Manna,
D. Margarone,
G. Milluzzo,
S. Pulvirenti,
F. Romano,
S. Salamone,
M. Sedita,
V. Scuderia,
A. Tramontana
Abstract:
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be deve…
▽ More
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be developed by INFN-LNS (It) and installed at the ELI-Beamlines facility in Prague (Cz). ELIMED will be the first users open transport beam-line where a controlled laser-driven ion beam will be used for multidisciplinary researches. The definition of well specified characteristics, both in terms of performances and field quality, of the magnetic lenses is crucial for the system realization, for the accurate study of the beam dynamics and for the proper matching with the magnetic selection system which will be designed in the next months.
Here, we report the design of the collection system and the adopted solutions in order to realize a robust system form the magnetic point of view. Moreover, the first preliminary transport simulations are also described.
△ Less
Submitted 1 January, 2022;
originally announced January 2022.
-
Optical and mechanical properties of ion-beam-sputtered MgF$_2$ thin films for gravitational-wave interferometers
Authors:
M. Granata,
A. Amato,
M. Bischi,
M. Bazzan,
G. Cagnoli,
M. Canepa,
M. Chicoine,
A. Di Michele,
G. Favaro,
D. Forest,
G. M. Guidi,
G. Maggioni,
F. Martelli,
M. Menotta,
M. Montani,
F. Piergiovanni,
F. Schiettekatte
Abstract:
Brownian thermal noise associated with highly reflective coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Research is currently ongoing to find coatings with low thermal noise that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered magnesium f…
▽ More
Brownian thermal noise associated with highly reflective coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Research is currently ongoing to find coatings with low thermal noise that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered magnesium fluoride thin films, and we discuss the application of such coatings in current and future gravitational-wave detectors.
△ Less
Submitted 24 March, 2022; v1 submitted 2 November, 2021;
originally announced November 2021.
-
Exploration of co-sputtered Ta$_2$O$_5$-ZrO$_2$ thin films for gravitational-wave detectors
Authors:
M. Abernathy,
A. Amato,
A. Ananyeva,
S. Angelova,
B. Baloukas,
R. Bassiri,
G. Billingsley,
R Birney,
G. Cagnoli,
M. Canepa,
M. Coulon,
J. Degallaix,
A. Di Michele,
M. A. Fazio,
M. M. Fejer,
D. Forest,
C. Gier,
M. Granata,
A. M. Gretarsson,
E. M. Gretarsson,
E. Gustafson,
E. J. Hough,
M. Irving,
É. Lalande,
C. Lévesque
, et al. (23 additional authors not shown)
Abstract:
We report on the development and extensive characterization of co-sputtered tantala-zirconia thin films, with the goal to decrease coating Brownian noise in present and future gravitational-wave detectors. We tested a variety of sputtering processes of different energies and deposition rates, and we considered the effect of different values of cation ratio $η=$ Zr/(Zr+Ta) and of post-deposition he…
▽ More
We report on the development and extensive characterization of co-sputtered tantala-zirconia thin films, with the goal to decrease coating Brownian noise in present and future gravitational-wave detectors. We tested a variety of sputtering processes of different energies and deposition rates, and we considered the effect of different values of cation ratio $η=$ Zr/(Zr+Ta) and of post-deposition heat treatment temperature $T_a$ on the optical and mechanical properties of the films. Co-sputtered zirconia proved to be an efficient way to frustrate crystallization in tantala thin films, allowing for a substantial increase of the maximum annealing temperature and hence for a decrease of coating mechanical loss. The lowest average coating loss was observed for an ion-beam sputtered sample with $η= 0.485 \pm 0.004$ annealed at 800 $^{\circ}$C, yielding $\overline{\varphi} = 1.8 \times 10^{-4}$. All coating samples showed cracks after annealing. Although in principle our measurements are sensitive to such defects, we found no evidence that our results were affected. The issue could be solved, at least for ion-beam sputtered coatings, by decreasing heating and cooling rates down to 7 $^{\circ}$C/h. While we observed as little optical absorption as in the coatings of current gravitational-wave interferometers (0.5 parts per million), further development will be needed to decrease light scattering and avoid the formation of defects upon annealing.
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Optical and mechanical properties of ion-beam-sputtered Nb$_2$O$_5$ and TiO$_2$-Nb$_2$O$_5$ thin films for gravitational-wave interferometers
Authors:
N. Demos,
M. Granata,
S. Gras,
A. Amato,
G. Cagnoli,
B. Sassolas,
J. Degallaix,
D. Forest,
C. Michel,
L. Pinard,
M. Evans,
A. Di Michele,
M. Canepa
Abstract:
Brownian thermal noise associated with highly-reflective mirror coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Recently, there has been a worldwide effort to find mirror coatings with improved thermal noise properties that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical…
▽ More
Brownian thermal noise associated with highly-reflective mirror coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Recently, there has been a worldwide effort to find mirror coatings with improved thermal noise properties that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered niobia and titania-niobia thin films, and we discuss application of such coatings in current and future gravitational-wave detectors. We also report an updated direct coating thermal noise measurement of the HR coatings used in Advanced LIGO and Advanced Virgo.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
Progress in the measurement and reduction of thermal noise in optical coatings for gravitational-wave detectors
Authors:
Massimo Granata,
Alex Amato,
Gianpietro Cagnoli,
Matthieu Coulon,
Jérôme Degallaix,
Danièle Forest,
Lorenzo Mereni,
Christophe Michel,
Laurent Pinard,
Benoît Sassolas,
Julien Teillon
Abstract:
Coating thermal noise is a fundamental limit for precision experiments based on optical and quantum transducers. In this review, after a brief overview of the techniques for coating thermal noise measurements, we present the latest world-wide research activity on low-noise coatings, with a focus on the results obtained at the Laboratoire des Matériaux Avancés. We report new updated values for the…
▽ More
Coating thermal noise is a fundamental limit for precision experiments based on optical and quantum transducers. In this review, after a brief overview of the techniques for coating thermal noise measurements, we present the latest world-wide research activity on low-noise coatings, with a focus on the results obtained at the Laboratoire des Matériaux Avancés. We report new updated values for the Ta$_2$O$_5$, Ta$_2$O$_5$-TiO$_2$ and SiO$_2$ coatings of the Advanced LIGO, Advanced Virgo and KAGRA detectors, and new results from sputtered Nb$_2$O$_5$, TiO$_2$-Nb$_2$O$_5$, Ta$_2$O$_5$-ZrO$_2$, MgF$_2$, AlF$_3$ and silicon nitride coatings. Amorphous silicon, crystalline coatings, high-temperature deposition, multi-material coatings and composite layers are also briefly discussed, together with the latest developments of structural analyses and models.
△ Less
Submitted 21 January, 2020; v1 submitted 21 December, 2019;
originally announced December 2019.
-
Amorphous optical coatings of present gravitational-wave interferometers
Authors:
Massimo Granata,
Alex Amato,
Laurent Balzarini,
Maurizio Canepa,
Jérôme Degallaix,
Danièle Forest,
Vincent Dolique,
Lorenzo Mereni,
Christophe Michel,
Laurent Pinard,
Benoît Sassolas,
Julien Teillon,
Gianpietro Cagnoli
Abstract:
We report on the results of an extensive campaign of optical and mechanical characterization of the ion-beam sputtered oxide layers (Ta$_2$O$_5$, TiO$_2$, Ta$_2$O$_5$-TiO$_2$, SiO$_2$) within the high-reflection coatings of the Advanced LIGO, Advanced Virgo and KAGRA gravitational-wave detectors: refractive index, thickness, optical absorption, composition, density, internal friction and elastic c…
▽ More
We report on the results of an extensive campaign of optical and mechanical characterization of the ion-beam sputtered oxide layers (Ta$_2$O$_5$, TiO$_2$, Ta$_2$O$_5$-TiO$_2$, SiO$_2$) within the high-reflection coatings of the Advanced LIGO, Advanced Virgo and KAGRA gravitational-wave detectors: refractive index, thickness, optical absorption, composition, density, internal friction and elastic constants have been measured; the impact of deposition rate and post-deposition annealing on coating internal friction has been assessed. For Ta$_2$O$_5$ and SiO$_2$ layers, coating internal friction increases with the deposition rate, whereas the annealing treatment either erases or largely reduces the gap between samples with different deposition history. For Ta$_2$O$_5$-TiO$_2$ layers, the reduction of internal friction due to TiO$_2$ do** becomes effective only if coupled with annealing. All measured samples showed a weak dependence of internal friction on frequency ($φ_c(f) = af^{b}$, with $-0.208 < b < 0.140$ depending on the coating material considered). SiO$_2$ films showed a mode-dependent loss branching, likely due to spurious losses at the coated edge of the samples. The reference loss values of the Advanced LIGO and Advanced Virgo input (ITM) and end (ETM) mirror HR coatings have been updated by using our estimated value of Young's modulus of Ta$_2$O$_5$-TiO$_2$ layers (120 GPa) and are about 10\% higher than previous estimations.
△ Less
Submitted 9 September, 2019;
originally announced September 2019.
-
Observation of a Correlation Between Internal friction and Urbach Energy in Amorphous Oxides Thin Films
Authors:
Alex Amato,
Silvana Terreni,
Massimo Granata,
Christophe Michel,
Benoit Sassolas,
Laurent Pinard,
Maurizio Canepa,
Gianpietro Cagnoli
Abstract:
We have investigated by spectroscopic ellipsometry (SE, 190-1700 nm) the optical properties of uniform, amorphous thin films of Ta2O5 and Nb2O5 as deposited and after annealing, and after so-called "do**" with Ti atoms which leads to mixed oxides. Ta2O5 and Ti:Ta2O5 are currently used as high-index components in Bragg reflectors for Gravitational Wave Detectors. Parallel to the optical investiga…
▽ More
We have investigated by spectroscopic ellipsometry (SE, 190-1700 nm) the optical properties of uniform, amorphous thin films of Ta2O5 and Nb2O5 as deposited and after annealing, and after so-called "do**" with Ti atoms which leads to mixed oxides. Ta2O5 and Ti:Ta2O5 are currently used as high-index components in Bragg reflectors for Gravitational Wave Detectors. Parallel to the optical investigation, we measured the mechanical energy dissipation of the same coatings, through the so-called "loss angle" phi = Q^-1, which quantifies the energy loss in materials. By applying the well-known Cody-Lorentz model in the analysis of SE data we have been able to derive accurate information on the fundamental absorption edge through important parameters related to the electronic density of states, such as the optical gap (E_g) and the energy width of the exponential Urbach tail (the Urbach energy E_U). We have found that E_U is neatly reduced by suitable annealing as is also perceptible from direct inspection of SE data. Ti-do** also points to a minor decrease of E_U. The reduction of E_U parallels a lowering of the mechanical losses quantified by the loss angle phi. The correlation highlights that both the electronic states responsible of Urbach tail and the internal friction are sensitive to a self-correlation of defects on a medium-range scale, which is promoted by annealing and in our case, to a lesser extent, by do**. These observations may contribute to a better understanding of the relationship between structural and mechanical properties in amorphous oxides.
△ Less
Submitted 9 March, 2020; v1 submitted 14 March, 2019;
originally announced March 2019.
-
High-Reflection Coatings for Gravitational-Wave Detectors: State of The Art and Future Developments
Authors:
Alex Amato,
Gianpietro Cagnoli,
Maurizio Canepa,
Elodie Coillet,
Jerome Degallaix,
Vincent Dolique,
Daniele Forest,
Massimo Granata,
Valérie Martinez,
Christophe Michel,
Laurent Pinard,
Benoit Sassolas,
Julien Teillon
Abstract:
We report on the optical, mechanical and structural characterization of the sputtered coating materials of Advanced LIGO, Advanced Virgo and KAGRA gravitational-waves detectors. We present the latest results of our research program aiming at decreasing coating thermal noise through do**, optimization of deposition parameters and post-deposition annealing. Finally, we propose sputtered Si3N4 as a…
▽ More
We report on the optical, mechanical and structural characterization of the sputtered coating materials of Advanced LIGO, Advanced Virgo and KAGRA gravitational-waves detectors. We present the latest results of our research program aiming at decreasing coating thermal noise through do**, optimization of deposition parameters and post-deposition annealing. Finally, we propose sputtered Si3N4 as a candidate material for the mirrors of future detectors.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for $μ$SR measurements on a continuous-wave beam
Authors:
A. Amato,
H. Luetkens,
K. Sedlak,
A. Stoykov,
R. Scheuermann,
M. Elender,
A. Raselli,
D. Graf
Abstract:
We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (S$μ$S) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon instrument (GPS) which has been for long the workhorse of the $μ$SR user facility at PSI. By making us…
▽ More
We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (S$μ$S) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon instrument (GPS) which has been for long the workhorse of the $μ$SR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers (SiPMs), a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built $μ$SR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared to the old GPS.
△ Less
Submitted 2 October, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
Brownian regime of finite-N corrections to particle motion in the XY hamiltonian mean field model
Authors:
Bruno V Ribeiro,
Marco A Amato,
Yves Elskens
Abstract:
We study the dynamics of the N-particle system evolving in the XY hamiltonian mean field (HMF) model for a repulsive potential, when no phase transition occurs. Starting from a homogeneous distribution, particles evolve in a mean field created by the interaction with all others. This interaction does not change the homogeneous state of the system, and particle motion is approximately ballistic wit…
▽ More
We study the dynamics of the N-particle system evolving in the XY hamiltonian mean field (HMF) model for a repulsive potential, when no phase transition occurs. Starting from a homogeneous distribution, particles evolve in a mean field created by the interaction with all others. This interaction does not change the homogeneous state of the system, and particle motion is approximately ballistic with small corrections. For initial particle data approaching a waterbag, it is explicitly proved that corrections to the ballistic velocities are in the form of independent brownian noises over a time scale diverging not slower than $N^{2/5}$ as $N \to \infty$, which proves the propagation of molecular chaos. Molecular dynamics simulations of the XY-HMF model confirm our analytical findings.
△ Less
Submitted 18 May, 2016;
originally announced May 2016.
-
Collective modes in free plasmas subjected to a radiation field
Authors:
Bruno Vieira Ribeiro,
Daniel Dourado de A. Santos,
Marco A. Amato
Abstract:
In this study we report the effects of an external electromagnetic field on the collective properties of unmagnetized plasmas. The calculations are carried out in the semi-classical approximation, i.e., the electromagnetic field is treated classically and the electrons from a quantum mechanical viewpoint. The results show that the collective modes are damped away more smoothly and in a smaller fre…
▽ More
In this study we report the effects of an external electromagnetic field on the collective properties of unmagnetized plasmas. The calculations are carried out in the semi-classical approximation, i.e., the electromagnetic field is treated classically and the electrons from a quantum mechanical viewpoint. The results show that the collective modes are damped away more smoothly and in a smaller frequency range than those reported by previous studies. An exponential-like decay of the plasmon frequencies as a function of the external field amplitude is readily observed. We successfully recreate the results of previous studies. We also find that the single photon processes has a pronounced effect on the decrease of the frequency range of modulation.
△ Less
Submitted 18 April, 2013;
originally announced April 2013.
-
The 10 Tesla muSR instrument: detector solutions
Authors:
A. Stoykov,
R. Scheuermann,
K. Sedlak,
J. Rodriguez,
U. Greuter,
A. Amato
Abstract:
Solutions to the detector system of the High-Field muSR instrument at the Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical requirements are fulfilled through the application of Geiger-mode Avalanche Photodiodes.
Solutions to the detector system of the High-Field muSR instrument at the Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical requirements are fulfilled through the application of Geiger-mode Avalanche Photodiodes.
△ Less
Submitted 13 April, 2012;
originally announced April 2012.
-
A lens-coupled scintillation counter in cryogenic environment
Authors:
A. Stoykov,
R. Scheuermann,
A. Amato,
M. Bartkowiak,
J. A. Konter,
J. Rodriguez,
K. Sedlak
Abstract:
In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber loc…
▽ More
In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD) outside the cryostat, and a lens system guiding the scintillation light re-emitted by the fiber to the G-APD through optical windows in the cryostat shields. With a 0.8mm diameter multiclad fiber and a 1mm active area G-APD the coupling efficiency of the "lens light guide" is about 50%. A reliable performance of the detector down to 3K is demonstrated.
△ Less
Submitted 17 January, 2011;
originally announced January 2011.