-
Enhancing the light yield of He:CF$_4$ based gaseous detector
Authors:
F. D. Amaro,
R. Antonietti,
E. Baracchini,
L. Benussi,
S. Bianco,
R. Campagnola,
C. Capoccia,
M. Caponero,
D. S. Cardoso,
L. G. M. de Carvalho,
G. Cavoto,
I. Abritta Costa,
A. Croce,
E. Dané,
G. Dho,
F. Di Giambattista,
E. Di Marco,
M. D'Astolfo,
G. D'Imperio,
D. Fiorina,
F. Iacoangeli,
Z. Islam,
H. P. L. Jùnior,
E. Kemp,
G. Maccarrone
, et al. (29 additional authors not shown)
Abstract:
The CYGNO experiment aims to build a large ($\mathcal{O}(10)$ m$^3$) directional detector for rare event searches, such as nuclear recoils (NRs) induced by dark matter (DM), such as weakly interactive massive particles (WIMPs). The detector concept comprises a time projection chamber (TPC), filled with a He:CF$_4$ 60/40 scintillating gas mixture at room temperature and atmospheric pressure, equipp…
▽ More
The CYGNO experiment aims to build a large ($\mathcal{O}(10)$ m$^3$) directional detector for rare event searches, such as nuclear recoils (NRs) induced by dark matter (DM), such as weakly interactive massive particles (WIMPs). The detector concept comprises a time projection chamber (TPC), filled with a He:CF$_4$ 60/40 scintillating gas mixture at room temperature and atmospheric pressure, equipped with an amplification stage made of a stack of three gas electron multipliers (GEMs) which are coupled to an optical readout. The latter consists in scientific CMOS (sCMOS) cameras and photomultipliers tubes (PMTs). The maximisation of the light yield of the amplification stage plays a major role in the determination of the energy threshold of the experiment. In this paper, we simulate the effect of the addition of a strong electric field below the last GEM plane on the GEM field structure and we experimentally test it by means of a 10$\times$10 cm$^2$ readout area prototype. The experimental measurements analyse stacks of different GEMs and helium concentrations in the gas mixture combined with this extra electric field, studying their performances in terms of light yield, energy resolution and intrinsic diffusion. It is found that the use of this additional electric field permits large light yield increases without degrading intrinsic characteristics of the amplification stage with respect to the regular use of GEMs.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Charge Amplification in Low Pressure CF4:SF6:He Mixtures with a Multi-Mesh ThGEM for Directional Dark Matter Searches
Authors:
F. D. Amaro,
E. Baracchini,
L. Benussi,
S. Bianco,
F. Borra,
C. Capoccia,
M. Caponero,
D. S. Cardoso,
G. Cavoto,
I. A. Costa,
T. Crane,
E. Dane,
M. DAstolfo,
G. Dho,
F. Di Giambattista,
G. DImperio,
E. Di Marco,
J. M. F. Dos Santos,
A. C. Ezeribe,
D. Fiorina,
F. Iacoangeli,
H. P. Lima Junior,
G. S. P. Lopes,
G. Maccarrone,
R. D. P. Mano
, et al. (24 additional authors not shown)
Abstract:
The CYGNO collaboration is develo** next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below the Neutrino Fog. SF6 is potentially ideal for this since it provides a high fluorine content, enhancing sensitivity to spin-dependent interactions and, as a Neg…
▽ More
The CYGNO collaboration is develo** next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below the Neutrino Fog. SF6 is potentially ideal for this since it provides a high fluorine content, enhancing sensitivity to spin-dependent interactions and, as a Negative Ion Drift (NID) gas, reduces charge diffusion leading to improved positional resolution. CF4, although not a NID gas, has also been identified as a favourable gas target as it provides a scintillation signal which can be used for a complimentary light/charge readout approach. These gases can operate at low pressures to elongate Nuclear Recoil (NR) tracks and facilitate directional measurements. In principle, He could be added to low pressure SF6/CF4 without significant detriment to the length of 16S, 12C, and 19F recoils. This would improve the target mass, sensitivity to lower WIMP masses, and offer the possibility of atmospheric operation; potentially reducing the cost of a containment vessel. In this article, we present gas gain and energy resolution measurements, taken with a Multi-Mesh Thick Gaseous Electron Multiplier (MMThGEM), in low pressure SF6 and CF4:SF6 mixtures following the addition of He. We find that the CF4:SF6:He mixtures tested were able to produce gas gains on the order of 10^4 up to a total pressure of 100 Torr. These results demonstrate an order of magnitude improvement in charge amplification in NID gas mixtures with a He component.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
LIME -- a gas TPC prototype for directional Dark Matter search for the CYGNO experiment
Authors:
Fernando Domingues Amaro,
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Caponero,
Danilo Santos Cardoso,
Gianluca Cavoto,
André Cortez,
Igor Abritta Costa,
Emiliano Dané,
Giorgio Dho,
Flaminia Di Giambattista,
Emanuele Di Marco,
Giulia D'Imperio,
Francesco Iacoangeli,
Herman Pessoa Lima Junior,
Guilherme Sebastiao Pinheiro Lopes,
Giovanni Maccarrone,
Rui Daniel Passos Mano,
Robert Renz Marcelo Gregorio,
David José Gaspar Marques,
Giovanni Mazzitelli,
Alasdair Gregor McLean,
Andrea Messina
, et al. (22 additional authors not shown)
Abstract:
The CYGNO experiment aims at the development of a large gaseous TPC with GEM-based amplification and an optical readout by means of PMTs and scientific CMOS cameras for 3D tracking down to O(keV) energies, for the directional detection of rare events such as low mass Dark Matter and solar neutrino interactions. The largest prototype built so far towards the realisation of the CYGNO experiment demo…
▽ More
The CYGNO experiment aims at the development of a large gaseous TPC with GEM-based amplification and an optical readout by means of PMTs and scientific CMOS cameras for 3D tracking down to O(keV) energies, for the directional detection of rare events such as low mass Dark Matter and solar neutrino interactions. The largest prototype built so far towards the realisation of the CYGNO experiment demonstrator is the 50 L active volume LIME, with 4 PMTs and a single sCMOS imaging a 33$\times$33 cm\textsuperscript{2} area for 50 cm drift, that has been installed in underground Laboratori Nazionali del Gran Sasso in February 2022. We will illustrate LIME performances as evaluated overground in Laboratori Nazionali di Frascati by means of radioactive X-ray sources, and in particular the detector stability, energy response and energy resolution. We will discuss the MC simulation developed to reproduce the detector response and show the comparison with actual data. We will furthermore examine the background simulation worked out for LIME underground data taking and illustrate the foreseen expected measurement and results in terms of natural and materials intrinsic radioactivity characterisation and measurement of the LNGS underground natural neutron flux. The results that will be obtained by underground LIME installation will be paramount in the optimisation of the CYGNO demonstrator, since this is foreseen to be composed by multiple modules with the same LIME dimensions and characteristics.
△ Less
Submitted 29 June, 2023;
originally announced June 2023.
-
The CYGNO experiment, a directional detector for direct Dark Matter searches
Authors:
F. D. Amaro,
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
D. S. Cardoso,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Dané,
G. Dho,
F. Di Giambattista,
E. Di Marco,
G. D'Imperio,
F. Iacoangeli,
H. P. L. Jùnior,
G. S. P. Lopes,
G. Maccarrone,
R. D. P. Mano,
R. R. M. Gregorio,
D. J. G. Marques,
G. Mazzitelli,
A. G. McLean,
A. Messina
, et al. (22 additional authors not shown)
Abstract:
The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a He:CF$_4$ gas mixture at atmospheric pressure with a Gas Electron Multiplier (GEM) based amplification structure coupled to an optical readout comprised of sCMOS cam…
▽ More
The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a He:CF$_4$ gas mixture at atmospheric pressure with a Gas Electron Multiplier (GEM) based amplification structure coupled to an optical readout comprised of sCMOS cameras and photomultiplier tubes (PMTs). This experimental setup allows to achieve 3D tracking and background rejection down to O(1) keV energy, to boost sensitivity to low WIMP masses. The characteristics of the optical readout approach in terms of the light yield will be illustrated along with the particle identification properties. The project timeline foresees, in the next 2-3 years, the realisation and installation of a 0.4 m$^3$ TPC in the underground laboratories at LNGS to act as a demonstrator. Finally, the studies of the expected DM sensitivities of the CYGNO demonstrator will be presented.
△ Less
Submitted 7 June, 2023;
originally announced June 2023.
-
The helion charge radius from laser spectroscopy of muonic helium-3 ions
Authors:
The CREMA Collaboration,
Karsten Schuhmann,
Luis M. P. Fernandes,
François Nez,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth
, et al. (15 additional authors not shown)
Abstract:
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-…
▽ More
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-3 nucleus. This allowed us to extract the Lamb shift $E(2P_{1/2}-2S_{1/2})= 1258.598(48)^{\rm exp}(3)^{\rm theo}$ meV, the 2P fine structure splitting $E_{\rm FS}^{\rm exp} = 144.958(114)$ meV, and the 2S-hyperfine splitting (HFS) $E_{\rm HFS}^{\rm exp} = -166.495(104)^{\rm exp}(3)^{\rm theo}$ meV in $μ^3$He$^+$. Comparing these measurements to theory we determine the rms charge radius of the helion ($^3$He nucleus) to be $r_h$ = 1.97007(94) fm. This radius represents a benchmark for few nucleon theories and opens the way for precision tests in $^3$He atoms and $^3$He-ions. This radius is in good agreement with the value from elastic electron scattering, but a factor 15 more accurate. Combining our Lamb shift measurement with our earlier one in $μ^4$He$^+$ we obtain $r_h^2-r_α^2 = 1.0636(6)^{\rm exp}(30)^{\rm theo}$ fm$^2$ to be compared to results from the isotope shift measurements in regular He atoms, which are however affected by long-standing tensions. By comparing $E_{\rm HFS}^{\rm exp}$ with theory we also obtain the two-photon-exchange contribution (including higher orders) which is another important benchmark for ab-initio few-nucleon theories aiming at understanding the magnetic and current structure of light nuclei.
△ Less
Submitted 25 June, 2023; v1 submitted 19 May, 2023;
originally announced May 2023.
-
Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen
Authors:
J. Nuber,
A. Adamczak,
M. Abdou Ahmed,
L. Affolter,
F. D. Amaro,
P. Amaro,
P. Carvalho,
Y. -H. Chang,
T. -L. Chen,
W. -L. Chen,
L. M. P. Fernandes,
M. Ferro,
D. Goeldi,
T. Graf,
M. Guerra,
T. W. Hänsch,
C. A. O. Henriques,
M. Hildebrandt,
P. Indelicato,
O. Kara,
K. Kirch,
A. Knecht,
F. Kottmann,
Y. -W. Liu,
J. Machado
, et al. (24 additional authors not shown)
Abstract:
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The…
▽ More
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.
△ Less
Submitted 24 May, 2023; v1 submitted 15 November, 2022;
originally announced November 2022.
-
Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Authors:
Dan Shaked-Renous,
Fernando Domingues Amaro,
Purba Bhattacharya,
Amos Breskin,
Maximilien Chefdeville,
Cyril Drancourt,
Theo Geralis,
Yannis Karyotakis,
Luca Moleri,
Andrea Tesi,
Maxim Titov,
Joao Veloso,
Guillaum Vouters,
Shikma Bressler
Abstract:
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average…
▽ More
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average pad-multiplicity. We summarize here the experimental test-beam results of a small-size DHCAL prototype, incorporating six Micromegas (MM) and two Resistive-Plate WELL (RPWELL) sampling elements, interlaced with steel-absorber plates. It was investigated with 2-6 GeV pion beam at the CERN/PS beam facility. The data permitted validating a GEANT4 simulation framework of a DHCAL, and evaluating the expected pion energy resolution of a full-scale RPWELL-based calorimeter. The pion energy resolution of $\fracσ{E[GeV]}=\frac{50.8\%}{\sqrt{E[GeV]}} \oplus 10.3\%$ derived expected with the RPWELL concept is competitive to that of glass RPC and MM sampling techniques.
△ Less
Submitted 7 October, 2022; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Improving position resolution of neutron detectors with ultra-thin B4C foils
Authors:
N. F. V. Duarte,
J. S. Marcos,
A. Antognini,
C. Klauser,
S. A. Felix,
C. M. B. Monteiro,
F. D. Amaro
Abstract:
A new technique for detection of slow neutrons with gaseous detectors using ultra-thin layers with 10B atoms is presented. The reaction between a thermal neutron and a 10B atom releases 2 secondary particles, namely a 7Li ion and an alpha particle, which due to momentum conservation are emitted in opposite directions, along the same line (back to back). Current boron coated neutron detectors are e…
▽ More
A new technique for detection of slow neutrons with gaseous detectors using ultra-thin layers with 10B atoms is presented. The reaction between a thermal neutron and a 10B atom releases 2 secondary particles, namely a 7Li ion and an alpha particle, which due to momentum conservation are emitted in opposite directions, along the same line (back to back). Current boron coated neutron detectors are equipped with 10B films with thicknesses of several micrometers, deposited on very thick substrate plates. However, since the ranges of the 7Li ion and the alpha particle are of few micrometeres in most materials, one of these particles is always lost in the 10B layer or substrate. As such, these detectors lose the ability to reconstruct the reaction line of action and to precisely determine the neutron position, as only one of the two secondary particles track can be measured. With the technique now presented, the sum of the 10B layer and the substrate thicknesses is small enough to allow for both secondary particles to escape and ionize the gas in opposite sides of the 10B converter foil. Independent readout structures, one on each side of the 10B converter foil, detect each secondary particle and determine its track centroid and the deposited energy. Since the two secondary particles are emitted back to back, the neutron position can be obtained by combining the information recorded by the two readout structures. Through GEANT4 simulations, we verified that the spatial resolution can be significantly improved: our results show that, by using a B4C layer with a thickness of 1 micron on a 0.9 micron Mylar substrate, the spatial resolution can by improved by a factor of 8, compared to conventional detectors with thick 10B detection layers.
△ Less
Submitted 26 February, 2022;
originally announced February 2022.
-
The CYGNO Experiment
Authors:
Fernando Domingues Amaro,
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Caponero,
Danilo Santos Cardoso,
Gianluca Cavoto,
André Cortez,
Igor Abritta Costa,
Rita Joanna da Cruz Roque,
Emiliano Dané,
Giorgio Dho,
Flaminia Di Giambattista,
Emanuele Di Marco,
Giovanni Grilli di Cortona,
Giulia D'Imperio,
Francesco Iacoangeli,
Herman Pessoa Lima Júnior,
Guilherme Sebastiao Pinheiro Lopes,
Amaro da Silva Lopes Júnior,
Giovanni Maccarrone,
Rui Daniel Passos Mano,
Michela Marafini,
Robert Renz Marcelo Gregorio
, et al. (25 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its proper…
▽ More
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Laser excitation of the 1s-hyperfine transition in muonic hydrogen
Authors:
P. Amaro,
A. Adamczak,
M. Abdou Ahmed,
L. Affolter,
F. D. Amaro,
P. Carvalho,
T. -L. Chen,
L. M. P. Fernandes,
M. Ferro,
D. Goeldi,
T. Graf,
M. Guerra,
T. W. Hänsch,
C. A. O. Henriques,
Y. -C. Huang,
P. Indelicato,
O. Kara,
K. Kirch,
A. Knecht,
F. Kottmann,
Y. -W. Liu,
J. Machado,
M. Marszalek,
R. D. P. Mano,
C. M. B. Monteiro
, et al. (21 additional authors not shown)
Abstract:
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine…
▽ More
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $μ$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $μ$p is formed and the laser spectroscopy will occur.
△ Less
Submitted 7 June, 2022; v1 submitted 30 November, 2021;
originally announced December 2021.
-
Electroluminescence yield in pure krypton
Authors:
R. D. P. Mano,
C. A. O. Henriques,
F. D. Amaro,
C. M. B. Monteiro
Abstract:
The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the electroluminescence pulses as well as the direct interaction of x-rays, the latter being used as a reference for the calculation of the number of charge carriers produced by t…
▽ More
The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the electroluminescence pulses as well as the direct interaction of x-rays, the latter being used as a reference for the calculation of the number of charge carriers produced by the electroluminescence pulses and, thus, the determination of the number of photons im**ing the photodiode. An amplification parameter of 113 photons per kV per drifting electron and a scintillation threshold of 2.7 Td ( 0.7 kV/cm/bar at 293 K ) was obtained, in good agreement with the simulation data reported in the literature. On the other hand, the ionisation threshold in krypton was found to be around 13.5 Td (3.4 kV/cm/bar), less than what had been obtained by the most recent simulation work-package. The krypton amplification parameter is about 80% and 140% of those measured for xenon and argon, respectively. The electroluminescence yield in krypton is of great importance for modeling krypton-based double-phase or high-pressure gas detectors, which may be used in future rare event detection experiments.
△ Less
Submitted 29 January, 2021;
originally announced February 2021.
-
$^{222}$Rn emanation measurements for the XENON1T experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (118 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation me…
▽ More
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $^{222}$Rn activity concentration of 10 $μ$Bq/kg in 3.2 t of xenon. The knowledge of the distribution of the $^{222}$Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $^{222}$Rn activity concentration in XENON1T. The final $^{222}$Rn activity concentration of (4.5 $\pm$ 0.1) $μ$Bq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.
△ Less
Submitted 25 November, 2020; v1 submitted 29 September, 2020;
originally announced September 2020.
-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (109 additional authors not shown)
Abstract:
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, whic…
▽ More
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.
△ Less
Submitted 18 August, 2020; v1 submitted 30 July, 2019;
originally announced July 2019.
-
XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (103 additional authors not shown)
Abstract:
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exp…
▽ More
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exposure of science data was collected between October 2016 and February 2018. This article reports on the performance of the detector during this period and describes details of the data analysis that led to the most stringent exclusion limits on various WIMP-nucleon interaction models to date. In particular, signal reconstruction, event selection and calibration of the detector response to nuclear and electronic recoils in XENON1T are discussed.
△ Less
Submitted 4 November, 2019; v1 submitted 11 June, 2019;
originally announced June 2019.
-
The XENON1T Data Acquisition System
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (108 additional authors not shown)
Abstract:
The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extrem…
▽ More
The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extremely low signal threshold below a tenth of a photoelectron using a parallelized readout with the global trigger deferred to a later, software stage. The event identification is based on MongoDB database queries and has over 97% efficiency at recognizing interactions at the analysis energy threshold. A readout bandwidth over 300 MB/s is reached in calibration modes and is further expandable via parallelization. This DAQ system was successfully used during three years of operation of XENON1T.
△ Less
Submitted 7 August, 2019; v1 submitted 3 June, 2019;
originally announced June 2019.
-
XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad,
J. P. Cussonneau
, et al. (101 additional authors not shown)
Abstract:
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in…
▽ More
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in the central volume of XENON1T detector is the lowest achieved so far with a liquid xenon-based direct detection experiment. In this work we describe the response model of the detector, the background and signal models, and the statistical inference procedures used in the dark matter searches with a 1 tonne$\times$year exposure of XENON1T data, that leaded to the best limit to date on WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c$^2$.
△ Less
Submitted 28 February, 2019; v1 submitted 28 February, 2019;
originally announced February 2019.
-
The next generation of laser spectroscopy experiments using light muonic atoms
Authors:
S. Schmidt,
M. Willig,
J. Haack,
R. Horn,
A. Adamczak,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
P. Carvalho,
T. -L. Chen,
L. M. P. Fernandes,
T. Graf,
M. Guerra,
T. W. Hänsch,
M. Hildebrandt,
Y. -C. Huang,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu,
J. Machado
, et al. (19 additional authors not shown)
Abstract:
Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent resu…
▽ More
Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($μ$p) and helium ($μ$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (95 additional authors not shown)
Abstract:
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra…
▽ More
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level.
△ Less
Submitted 13 September, 2018; v1 submitted 31 May, 2018;
originally announced May 2018.
-
Gain characteristics of a 100 micrometer thick GEM in Krypton-CO2 mixtures
Authors:
R. C. Roque,
H. Natal da Luz,
L. F. N. D. Carramate,
C. D. R. Azevedo,
J. A. Mir,
F. D. Amaro
Abstract:
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10x10 cm2 for the entire detection system. For each mixture, the effective gain an…
▽ More
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10x10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy resolution of 22% (FWHM) were achieved in pure krypton under stable conditions, showing the potential of the experimental setup for the following imaging studies.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (94 additional authors not shown)
Abstract:
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two l…
▽ More
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence on the drift field and photon detection efficiency are investigated at these low energies. The results provide new measurements in the energy region of interest for dark matter searches using liquid xenon.
△ Less
Submitted 1 February, 2018; v1 submitted 28 September, 2017;
originally announced September 2017.
-
The XENON1T Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
B. Antunes,
F. Arneodo,
M. Balata,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso
, et al. (120 additional authors not shown)
Abstract:
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomu…
▽ More
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
△ Less
Submitted 23 August, 2017;
originally announced August 2017.
-
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (93 additional authors not shown)
Abstract:
In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main t…
▽ More
In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of $\sim$ 4 years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.
△ Less
Submitted 3 March, 2018; v1 submitted 11 August, 2017;
originally announced August 2017.
-
The proton radius puzzle
Authors:
J. J. Krauth,
K. Schuhmann,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
J. M. R. Cardoso,
M. L. Carvalho,
D. S. Covita,
A. Dax,
S. Dhawan,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. Giesen,
A. L. Gouvea,
J. Götzfried,
T. Graf,
M. Guerra,
J. Haack,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien
, et al. (27 additional authors not shown)
Abstract:
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muon…
▽ More
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.
△ Less
Submitted 19 August, 2017; v1 submitted 2 June, 2017;
originally announced June 2017.
-
Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (91 additional authors not shown)
Abstract:
We present the first constraints on the spin-dependent, inelastic scattering cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a dual-phase xenon time projection chamber with 62\,kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuc…
▽ More
We present the first constraints on the spin-dependent, inelastic scattering cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a dual-phase xenon time projection chamber with 62\,kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuclear recoils from WIMP-nucleus interactions. Here we explore inelastic scattering, where a transition to a low-lying excited nuclear state of $^{129}$Xe is induced. The experimental signature is a nuclear recoil observed together with the prompt de-excitation photon. We see no evidence for such inelastic WIMP-$^{129}$Xe interactions. A profile likelihood analysis allows us to set a 90\% C.L. upper limit on the inelastic, spin-dependent WIMP-nucleon cross section of $3.3 \times 10^{-38}$\,cm$^{2}$ at 100\,GeV/c$^2$. This is the most constraining result to date, and sets the pathway for an analysis of this interaction channel in upcoming, larger dual-phase xenon detectors.
△ Less
Submitted 1 May, 2017;
originally announced May 2017.
-
Material radioassay and selection for the XENON1T dark matter experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calven,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (96 additional authors not shown)
Abstract:
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T ex…
▽ More
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations.
△ Less
Submitted 4 May, 2017;
originally announced May 2017.
-
Search for magnetic inelastic dark matter with XENON100
Authors:
XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (90 additional authors not shown)
Abstract:
We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results…
▽ More
We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results from other direct detection experiments. No candidate event has been found in the region of interest and upper limits on the WIMP's magnetic dipole moment are derived. The scenarios proposed to explain the DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of WIMPs with masses of 58.0 GeV/c$^2$ and 122.7 GeV/c$^2$ are excluded at 3.3 $σ$ and 9.3 $σ$, respectively.
△ Less
Submitted 31 October, 2017; v1 submitted 19 April, 2017;
originally announced April 2017.
-
Online $^{222}$Rn removal by cryogenic distillation in the XENON100 experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (97 additional authors not shown)
Abstract:
We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant $^{222}$Rn background originating from radon emanation. After inserting an auxiliary $^{222}$Rn emanati…
▽ More
We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant $^{222}$Rn background originating from radon emanation. After inserting an auxiliary $^{222}$Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the $^{222}$Rn activity concentration inside the XENON100 detector.
△ Less
Submitted 2 June, 2017; v1 submitted 22 February, 2017;
originally announced February 2017.
-
Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Butikofer,
J. Calven,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (89 additional authors not shown)
Abstract:
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. Ther…
▽ More
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in the low energy region of $(2.0-5.8)$ keV in the single scatter event sample, with a global significance of $1.9\,σ$, however no other more significant modulation is observed. The expected annual modulation of a dark matter signal is not compatible with this result. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at $5.7\,σ$.
△ Less
Submitted 3 January, 2017;
originally announced January 2017.
-
Removing krypton from xenon by cryogenic distillation to the ppq level
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (97 additional authors not shown)
Abstract:
The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the $β$-emitter $^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentratio…
▽ More
The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the $β$-emitter $^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon $\rm{^{nat}}$Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10$^{-15}$ mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4$\cdot$10$^5$ with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of $\rm{^{nat}}$Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
△ Less
Submitted 8 May, 2017; v1 submitted 13 December, 2016;
originally announced December 2016.
-
Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Butikofer,
J. Calven,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (96 additional authors not shown)
Abstract:
A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below b…
▽ More
A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220/Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.
△ Less
Submitted 25 April, 2017; v1 submitted 10 November, 2016;
originally announced November 2016.
-
XENON100 Dark Matter Results from a Combination of 477 Live Days
Authors:
XENON100 Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (92 additional authors not shown)
Abstract:
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$…
▽ More
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $\times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and 90% confidence level. We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 $\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50 GeV/$c^2$, at 90% confidence level.
△ Less
Submitted 12 January, 2017; v1 submitted 20 September, 2016;
originally announced September 2016.
-
Laser Spectroscopy of Muonic Atoms and Ions
Authors:
Randolf Pohl,
François Nez,
Luis M. P. Fernandes,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Adolf Giesen,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Paul Knowles
, et al. (22 additional authors not shown)
Abstract:
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of…
▽ More
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of the proton and deuteron radii are 10 and 3 times more accurate than the respective CODATA values, but 7 standard deviations smaller. Data on muonic helium-3 and -4 ions is being analyzed and will give new insights. In future, the (magnetic) Zemach radii of the proton and the helium-3 nuclei will be determined from laser spectroscopy of the 1S hyperfine splittings, and the Lamb shifts of muonic Li, Be and B can be used to improve the respective charge radii.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Search for Two-Neutrino Double Electron Capture of $^{124}$Xe with XENON100
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (92 additional authors not shown)
Abstract:
Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of d…
▽ More
Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$ yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of $T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
△ Less
Submitted 16 February, 2017; v1 submitted 12 September, 2016;
originally announced September 2016.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
DARWIN: towards the ultimate dark matter detector
Authors:
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
C. Amsler,
E. Aprile,
L. Arazi,
F. Arneodo,
P. Barrow,
L. Baudis,
M. L. Benabderrahmane,
T. Berger,
B. Beskers,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. Calven,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (94 additional authors not shown)
Abstract:
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible…
▽ More
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
△ Less
Submitted 22 June, 2016;
originally announced June 2016.
-
A low-mass dark matter search using ionization signals in XENON100
Authors:
XENON100 Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown S. Bruenner,
G. Bruno,
R. Budnik,
A. Buss,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (86 additional authors not shown)
Abstract:
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By drop** the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be…
▽ More
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By drop** the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\% confidence level.
△ Less
Submitted 19 December, 2016; v1 submitted 20 May, 2016;
originally announced May 2016.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, drop** by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
Physics reach of the XENON1T dark matter experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
L. Arazi,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
T. Berger,
P. Breur,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon
, et al. (91 additional authors not shown)
Abstract:
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and (…
▽ More
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_χ$=$50$ GeV/$c^2$.
△ Less
Submitted 15 April, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
First in-beam studies of a Resistive-Plate WELL gaseous multiplier
Authors:
S. Bressler,
L. Moleri,
M. Pitt,
S. Kudella,
D. C. R. Azevedo,
F. D. Amaro,
M. R. Jorge,
J. M. F. dos Santos,
J. F. C. A. Veloso,
H. Natal da Luz,
L. Arazi,
E. Olivieri,
A. Breskin
Abstract:
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar…
▽ More
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
△ Less
Submitted 20 January, 2016; v1 submitted 11 October, 2015;
originally announced October 2015.
-
Experiments towards resolving the proton charge radius puzzle
Authors:
A. Antognini,
K. Schuhmann,
F. D. Amaro,
P. Amaro,
M. Abdou-Ahmed,
F. Biraben,
T. -L. Chen,
D. S. Covita,
A. J. Dax,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. L. Gouvea,
J. Götzfried,
T. Graf,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu
, et al. (12 additional authors not shown)
Abstract:
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
△ Less
Submitted 17 October, 2015; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Improved X-ray detection and particle identification with avalanche photodiodes
Authors:
Marc Diepold,
Luis M. P. Fernandes,
Jorge Machado,
Pedro Amaro,
Marwan Abdou-Ahmed,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu
, et al. (14 additional authors not shown)
Abstract:
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to acco…
▽ More
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Lifetime and population of the 2S state in muonic protium and deuterium
Authors:
Marc Diepold,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Luis M. P. Fernandes,
Adolf Giesen,
Andrea L. Gouvea,
Thomas Graf,
Theodor W. Hänsch,
Paul Indelicato,
Lucile Julien,
Cheng-Yang Kao,
Paul Knowles,
Franz Kottmann,
Eric-Olivier Le Bigot,
Yi-Wei Liu,
José A. M. Lopes,
Livia Ludhova,
Cristina M. B. Monteiro,
Françoise Mulhauser,
Tobias Nebel
, et al. (10 additional authors not shown)
Abstract:
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The sho…
▽ More
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The short-lived 2S component has a population of 1.35 +0.57 -0.33 % and a lifetime of τ_short(μd) = 138 +32 -34 ns. We see evidence for RD of long-lived μd(2S) with a lifetime of τ_long(μd) = 1.15 +0.75 -0.53 μs. This is interpreted as formation and decay of excited muonic molecules.
△ Less
Submitted 10 October, 2013; v1 submitted 25 July, 2013;
originally announced July 2013.
-
Characterization of the Hamamatsu S8664 Avalanche Photodiode for X-Ray and VUV-light detection
Authors:
T. Lux,
E. D. C. Freitas,
F. D. Amaro,
O. Ballester,
G. V. Jover-Manas,
C. Martin,
C. M. B. Monteiro,
F. Sanchez,
J. Rico
Abstract:
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
△ Less
Submitted 5 January, 2012; v1 submitted 25 August, 2011;
originally announced August 2011.
-
The Thick-COBRA: a New Gaseous Electron Multiplier for Radiation Detectors
Authors:
F. D. Amaro,
C. Santos,
J. F. C. A. Veloso,
A. Breskin,
R. Chechik,
J. M. F. dos Santos
Abstract:
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between…
▽ More
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.
△ Less
Submitted 4 August, 2010;
originally announced August 2010.
-
Development of high-gain gaseous photomultipliers for the visible spectral range
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. Dos Santos,
F. D. Amaro,
J. F. C. A. Veloso
Abstract:
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the elec…
▽ More
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photocathodes and report on their stability and QE in gas; K$_2$CsSb photocathodes yielded QE values in Ar/CH$_4$(95/5) above 30% at wavelengths of 360-400 nm. The novel gaseous photomultiplier yielded stable operation at gains of 10$^5$, in continuous operation mode, in 700 Torr of this gas; its sensitivity to single photons was demonstrated. Other properties are described. The successful detection of visible light with this gas-photomultiplier pave ways towards further development of large-area sealed imaging detectors, of flat geometry, insensitive to magnetic fields, which might have significant impact on light detection in numerous fields.
△ Less
Submitted 5 May, 2009; v1 submitted 1 May, 2009;
originally announced May 2009.
-
High-gain DC-mode operated Gaseous Photomultipliers for the visible spectral range
Authors:
A. Lyashenko,
A. Breskin,
R. Chechik,
F. D. Amaro,
J. Veloso,
J. M. F. Dos Santos
Abstract:
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
△ Less
Submitted 12 August, 2008; v1 submitted 11 August, 2008;
originally announced August 2008.