The Straw Tracking Detector for the Fermilab Muon $g-2$ Experiment
Authors:
B. T. King,
T. Albahri,
S. Al-Kilani,
D. Allspach,
D. Beckner,
A. Behnke,
T. J. V. Bowcock,
D. Boyden,
R. M. Carey,
J. Carroll,
B. C. K. Casey,
S. Charity,
R. Chislett,
M. Eads,
A. Epps,
S. B. Foster,
D. Gastler,
S. Grant,
T. Halewood-Leagas,
K. Hardin,
E. Hazen,
G. Hesketh,
D. J. Hollywood,
T. Jones,
C. Kenziora
, et al. (32 additional authors not shown)
Abstract:
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuu…
▽ More
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of $(110 \pm 20) \,μ$m, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.
△ Less
Submitted 24 February, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.