-
Two-Photon EXchange -- TPEX
Authors:
R. Alarcon,
R. Beck,
J. C. Bernauer,
M. Broering,
E. Cline,
B. Dongwi,
I. Fernando,
M. Finger,
M. Finger Jr.,
I. Friščić,
T. Gautam,
D. K. Hasell,
O. Hen,
J. Holmes,
T. Horn,
E. Ihloff,
R. Johnston,
J. Kelsey,
M. Kohl,
T. Kutz,
I. Lavrukhin,
S. Lee,
W. Lorenzon,
F. Maas,
H. Merkel
, et al. (12 additional authors not shown)
Abstract:
We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of…
▽ More
We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of $2.12\times10^{35}$~cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\sim200$ times the luminosity achieved by OLYMPUS). A commissioning run at 2 GeV followed by measurements at 3 GeV would provide new data up to $Q^2=4.6$~(GeV/$c$)$^2$ (twice the range of current measurements). Lead tungstate calorimeters would be used to detect the scattered leptons at polar angles of $30^\circ$, $50^\circ$, $70^\circ$, $90^\circ$, and $110^\circ$. The measurements could be scheduled to not interfere with the operation of PETRA. We present rate estimates and simulations for the planned measurements including background considerations. Initial measurements at the DESY test beam facility using prototype lead tungstate calorimeters in 2019, 2021, and 2022 were made to check the Monte Carlo simulations and the performance of the calorimeters. These tests also investigated different readout schemes (triggered and streaming). Various upgrades are possible to shorten the running time and to make higher beam energies and thus greater $Q^2$ ranges accessible.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
CORE -- a COmpact detectoR for the EIC
Authors:
CORE Collaboration,
R. Alarcon,
M. Baker,
V. Baturin,
P. Brindza,
S. Bueltmann,
M. Bukhari,
R. Capobianco,
E. Christy,
S. Diehl,
M. Dugger,
R. Dupré,
R. Dzhygadlo,
K. Flood,
K. Gnanvo,
L. Guo,
T. Hayward,
M. Hattawy,
M. Hoballah,
M. Hohlmann,
C. E. Hyde,
Y. Ilieva,
W. W. Jacobs,
K. Joo,
G. Kalicy
, et al. (34 additional authors not shown)
Abstract:
The COmpact detectoR for the Eic (CORE) Proposal was submitted to the EIC "Call for Collaboration Proposals for Detectors". CORE comprehensively covers the physics scope of the EIC Community White Paper and the National Academies of Science 2018 report. The design exploits advances in detector precision and granularity to minimize size. The central detector includes a 3Tesla, 2.5m solenoid. Tracki…
▽ More
The COmpact detectoR for the Eic (CORE) Proposal was submitted to the EIC "Call for Collaboration Proposals for Detectors". CORE comprehensively covers the physics scope of the EIC Community White Paper and the National Academies of Science 2018 report. The design exploits advances in detector precision and granularity to minimize size. The central detector includes a 3Tesla, 2.5m solenoid. Tracking is primarily silicon. Electromagnetic calorimetry is based on the high performance crystals. Ring-imaging Cherenkov detectors provide hadronic particle identification.
△ Less
Submitted 1 September, 2022;
originally announced September 2022.
-
Searching for New Physics with DarkLight at the ARIEL Electron-Linac
Authors:
The DarkLight Collaboration,
E. Cline,
R. Corliss,
J. C. Bernauer,
R. Alarcon,
R. Baartman,
S. Benson,
J. Bessuille,
D. Ciarniello,
A. Christopher,
A. Colon,
W. Deconinck,
K. Dehmelt,
A. Deshpande,
J. Dilling,
D. H. Dongwi,
P. Fisher,
T. Gautam,
M. Gericke,
D. Hasell,
M. Hasinoff,
E. Ihloff,
R. Johnston,
R. Kanungo,
J. Kelsey
, et al. (21 additional authors not shown)
Abstract:
The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, w…
▽ More
The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.
△ Less
Submitted 14 August, 2022; v1 submitted 8 August, 2022;
originally announced August 2022.
-
Quantum optical coherence microscopy for bioimaging applications
Authors:
Pablo Yepiz-Graciano,
Zeferino Ibarra-Borja,
Roberto Ramírez Alarcón,
Gerardo Gutiérrez-Torres,
Héctor Cruz-Ramírez,
Dorilian Lopez-Mago,
Alfred B. U'Ren
Abstract:
Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of photon pairs, obtained from a spontaneous parametric downconversion (SPDC) source. The promise of QOCT derives from two quantum-conferred advantages when compared to equivalent classical optical coherence tomography (OCT) systems: a factor of 2 axial resolution enhancement, as well as…
▽ More
Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of photon pairs, obtained from a spontaneous parametric downconversion (SPDC) source. The promise of QOCT derives from two quantum-conferred advantages when compared to equivalent classical optical coherence tomography (OCT) systems: a factor of 2 axial resolution enhancement, as well as dispersion cancellation. However, the technique is far from being competitive with current OCT devices due to the long required acquisition times. Here, we on the one hand demonstrate a quantum optical coherence microscopy (QOCM) technique that is designed to overcome some of the limitations of previous QOCT implementations, and on the other hand test it on representative samples, including glass layers with manufactured transverse patterns and metal-coated biological specimens. We use a collinear SPDC source, so that the entire emitted photon pair flux may contribute to the measurements, together with a multi-mode detection design. We employ a Michelson interferometer with the sample placed as end-mirror in one of the interferometer arms, instead of the more typical Hong-Ou-Mandel used in QOCT implementations. In order to probe biological samples we transition from a Michelson to a Linnik interferometer by placing a microscope objective in the sample arm. In our setup, while the idler photon is collected with a multi-mode fiber, the signal photon is detected by an ICCD camera, leading to full-field transverse reconstruction through a single axial acquisition sequence. Interestingly, our setup permits concurrent OCT and QOCT trace acquisition, the former with greater counts and the latter with the benefit of quantum-conferred advantages. We hope that our current results will represent a significant step forward towards the actual applicability of QOCT, e.g. in clinical settings.
△ Less
Submitted 29 August, 2022; v1 submitted 2 May, 2022;
originally announced May 2022.
-
Ince-Gauss Photons in Turbulent Atmosphere: Effect of quantum numbers on beam resilience
Authors:
Emmanuel Narváez Castañeda,
Roberto Ramírez Alarcón,
José César Guerra Vázquez,
Imad Agha,
Qiwen Zhan,
William N. Plick
Abstract:
In this work, we present an extensive analysis on the nature and performance of Ince-Gauss beams, elliptical solutions of the paraxial wave equation that have orbital angular momentum, as information carriers in turbulent atmosphere. We perform numerical simulations of the propagation of these beams, and focus on the effects that the order, degree and ellipticity parameters have on the robustness…
▽ More
In this work, we present an extensive analysis on the nature and performance of Ince-Gauss beams, elliptical solutions of the paraxial wave equation that have orbital angular momentum, as information carriers in turbulent atmosphere. We perform numerical simulations of the propagation of these beams, and focus on the effects that the order, degree and ellipticity parameters have on the robustness of the beams. We find that the choice of basis in which a mode is constructed does not greatly influence the mode performance and it is instead strongly affected by the combination of order and degree values.
△ Less
Submitted 27 August, 2021;
originally announced August 2021.
-
Interference effects in quantum-optical coherence tomography using spectrally engineered photon pairs
Authors:
Pablo Yepiz Graciano,
Ali Michel Angulo Martinez,
Dorilian Lopez-Mago,
Gustavo Castro-Olvera,
Martha Rosete-Aguilar,
Jesus Garduño-Mejia,
Roberto Ramirez Alarcon,
Hector Cruz Ramirez,
Alfred B. U'Ren
Abstract:
Optical-coherence tomography (OCT) is a technique that employs light in order to measure the internal structure of semi-transparent, e.g. biological, samples. It is based on the interference pattern of low-coherence light. Quantum-OCT (QOCT), instead, employs the correlation properties of entangled photon pairs, for example, generated by the process of spontaneous parametric downconversion (SPDC).…
▽ More
Optical-coherence tomography (OCT) is a technique that employs light in order to measure the internal structure of semi-transparent, e.g. biological, samples. It is based on the interference pattern of low-coherence light. Quantum-OCT (QOCT), instead, employs the correlation properties of entangled photon pairs, for example, generated by the process of spontaneous parametric downconversion (SPDC). The usual QOCT scheme uses photon pairs characterised by a joint-spectral amplitude with strict spectral anti-correlations. It has been shown that, in contrast with its classical counterpart, QOCT provides resolution enhancement and dispersion cancellation. In this paper, we revisit the theory of QOCT and extend the theoretical model so as to include photon pairs with arbitrary spectral correlations. We present experimental results that complement the theory and explain the physical underpinnings appearing in the interference pattern. In our experiment, we utilize a pump for the SPDC process ranging from continuous wave to pulsed in the femtosecond regime, and show that cross-correlation interference effects appearing for each pair of layers may be directly suppressed for a sufficiently large pump bandwidth. Our results provide insights and strategies that could guide practical implementations of QOCT.
△ Less
Submitted 20 May, 2020;
originally announced May 2020.
-
Extending vacuum trap** to absorbing objects with hybrid Paul-optical traps
Authors:
Gerard Planes Conangla,
Raúl A. Rica Alarcón,
Romain Quidant
Abstract:
The levitation of condensed matter in vacuum allows the study of its physical properties under extreme isolation from the environment. It also offers a venue to investigate quantum mechanics with large systems, at the transition between the quantum and classical worlds. In this work, we study a novel hybrid levitation platform that combines a Paul trap with a weak but highly focused laser beam, a…
▽ More
The levitation of condensed matter in vacuum allows the study of its physical properties under extreme isolation from the environment. It also offers a venue to investigate quantum mechanics with large systems, at the transition between the quantum and classical worlds. In this work, we study a novel hybrid levitation platform that combines a Paul trap with a weak but highly focused laser beam, a configuration that integrates a deep potential with excellent confinement and motion detection. We combine simulations and experiments to demonstrate the potential of this approach to extend vacuum trap** and interrogation to a broader range of nanomaterials, such as absorbing particles. We study the stability and dynamics of different specimens, like fluorescent dielectric crystals and gold nanorods, and demonstrate stable trap** down to pressures of 1 mbar.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
A novel approach to building micromegas detectors enabled by precision manufacturing
Authors:
J. Holmes,
E. Galyaev,
R. Alarcon,
R. Acuna,
D. Blyth,
B. Fox,
N. Mullins,
K. Scheuer
Abstract:
Micromegas detectors are a relatively modern design concept for micropattern gas detectors, designed to handle high particle flux while providing high gain, high spatial resolution, and fast response times for a variety of radiation detection applications. Due to the advancement of industry, building a micromegas detector without advanced in-house capabilities is now possible. In this work, we pre…
▽ More
Micromegas detectors are a relatively modern design concept for micropattern gas detectors, designed to handle high particle flux while providing high gain, high spatial resolution, and fast response times for a variety of radiation detection applications. Due to the advancement of industry, building a micromegas detector without advanced in-house capabilities is now possible. In this work, we present an innovative method to build micromegas detectors utilizing precision manufacturers to fabricate the core components. Two detectors were built using the newly described method and are experimentally validated.
△ Less
Submitted 5 May, 2020; v1 submitted 19 February, 2020;
originally announced February 2020.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam
Authors:
S. Lee,
R. Corliss,
I. Friščić,
R. Alarcon,
S. Aulenbacher,
J. Balewski,
S. Benson,
J. C. Bernauer,
J. Bessuille,
J. Boyce,
J. Coleman,
D. Douglas,
C. S. Epstein,
P. Fisher,
S. Frierson,
M. Garçon,
J. Grames,
D. Hasell,
C. Hernandez-Garcia,
E. Ihloff,
R. Johnston,
K. Jordan,
R. Kazimi,
J. Kelsey,
M. Kohl
, et al. (15 additional authors not shown)
Abstract:
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamli…
▽ More
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab's Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight's experimental needs is feasible in an ERL environment.
△ Less
Submitted 30 May, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Performance of new silica aerogels in a threshold Cerenkov counter
Authors:
D. Blyth,
R. Alarcon,
R. Begag,
J. Holmes,
J. Stryker
Abstract:
New highly transparent, hydrophobic silica aerogels with refractive indices of 1.01 to 1.07 have been produced by Aspen Aerogels, Inc., and select tiles have been tested using an electron beam at the DESY, Hamburg facility. A diffusively-reflective threshold Cerenkov counter was designed and constructed for the purpose of evaluating the aerogels, and can accommodate aerogel tile areas of up to 20…
▽ More
New highly transparent, hydrophobic silica aerogels with refractive indices of 1.01 to 1.07 have been produced by Aspen Aerogels, Inc., and select tiles have been tested using an electron beam at the DESY, Hamburg facility. A diffusively-reflective threshold Cerenkov counter was designed and constructed for the purpose of evaluating the aerogels, and can accommodate aerogel tile areas of up to 20 cm by 20 cm. Measurements of the performance of the counter using the new aerogels as Cerenkov radiators are given in terms of photoelectron yields and a figure of merit.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
Precision Measurement of the Radiative $\Beta$ Decay of the Free Neutron
Authors:
M. J. Bales,
R. Alarcon,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
M. S. Dewey,
S. Gardner,
T. R. Gentile,
D. He,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was…
▽ More
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
△ Less
Submitted 26 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
The DarkLight Experiment: A Precision Search for New Physics at Low Energies
Authors:
J. Balewski,
J. Bernauer,
J. Bessuille,
R. Corliss,
R. Cowan,
C. Epstein,
P. Fisher,
D. Hasell,
E. Ihloff,
Y. Kahn,
J. Kelsey,
R. Milner,
S. Steadman,
J. Thaler,
C. Tschalaer,
C. Vidal,
S. Benson,
J. Boyce,
D. Douglas,
P. Evtushenko,
C. Hernandez-Garcia,
C. Keith,
C. Tennant,
S. Zhang,
R. Alarcon
, et al. (15 additional authors not shown)
Abstract:
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac inc…
▽ More
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac incident on a windowless gas target of molecular hydrogen. The complete final state including scattered electron, recoil proton, and e+e- pair will be detected. A phase-I experiment has been funded and is expected to take data in the next eighteen months. The complete phase-II experiment is under final design and could run within two years after phase-I is completed. The DarkLight experiment drives development of new technology for beam, target, and detector and provides a new means to carry out electron scattering experiments at low momentum transfers.
△ Less
Submitted 15 December, 2014;
originally announced December 2014.
-
New measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission
Authors:
K. B. Grammer,
R. Alarcon,
L. Barrón-Palos,
D. Blyth,
J. D. Bowman,
J. Calarco,
C. Crawford,
K. Craycraft,
D. Evans,
N. Fomin,
J. Fry,
M. Gericke,
R. C. Gillis,
G. L. Greene,
J. Hamblen,
C. Hayes,
S. Kucuker,
R. Mahurin,
M. Maldonado-Velázquez,
E. Martin,
M. McCrea,
P. E. Mueller,
M. Musgrave,
H. Nann,
S. I. Penttilä
, et al. (3 additional authors not shown)
Abstract:
Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function $g(r)$ inferred from neutron scattering measurements of the differential cross section $dσ\over dΩ$ from different measu…
▽ More
Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function $g(r)$ inferred from neutron scattering measurements of the differential cross section $dσ\over dΩ$ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43~meV and 16.1~meV on liquid hydrogen at 15.6~K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1~meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra non-equilibrium component of orthohydrogen. Liquid parahydrogen is also a widely-used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. We describe our measurements and compare them with previous work.
△ Less
Submitted 24 April, 2015; v1 submitted 8 October, 2014;
originally announced October 2014.
-
The OLYMPUS Experiment
Authors:
R. Milner,
D. K. Hasell,
M. Kohl,
U. Schneekloth,
N. Akopov,
R. Alarcon,
V. A. Andreev,
O. Ates,
A. Avetisyan,
D. Bayadilov,
R. Beck,
S. Belostotski,
J. C. Bernauer,
J. Bessuille,
F. Brinker,
B. Buck,
J. R. Calarco,
V. Carassiti,
E. Cisbani,
G. Ciullo,
M. Contalbrigo,
N. D'Ascenzo,
R. De Leo,
J. Diefenbach,
T. W. Donnelly
, et al. (48 additional authors not shown)
Abstract:
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and…
▽ More
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.
△ Less
Submitted 5 December, 2013;
originally announced December 2013.
-
DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility
Authors:
J. Balewski,
J. Bernauer,
W. Bertozzi,
J. Bessuille,
B. Buck,
R. Cowan,
K. Dow,
C. Epstein,
P. Fisher,
S. Gilad,
E. Ihloff,
Y. Kahn,
A. Kelleher,
J. Kelsey,
R. Milner,
C. Moran,
L. Ou,
R. Russell,
B. Schmookler,
J. Thaler,
C. Tschalär,
C. Vidal,
A. Winnebeck,
S. Benson,
C. Gould
, et al. (42 additional authors not shown)
Abstract:
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
△ Less
Submitted 19 July, 2013; v1 submitted 16 July, 2013;
originally announced July 2013.
-
Transmission of High-Power Electron Beams Through Small Apertures
Authors:
C. Tschalaer,
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
G. P. Williams,
S. Zhang,
.
Abstract:
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
△ Less
Submitted 31 May, 2013;
originally announced May 2013.
-
Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
W. J. Kossler,
R. Legg,
E. Long,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery…
▽ More
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.
△ Less
Submitted 30 May, 2013;
originally announced May 2013.
-
Transmission of Megawatt Relativistic Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performe…
▽ More
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performed using the 100 MeV, 430 kWatt CW electron beam from the energy recovery linac at the Jefferson Laboratory's Free Electron Laser facility as it traversed a set of small apertures in a 127 mm long aluminum block. Thermal measurements of the block together with neutron measurements near the beam-target interaction point yielded a consistent understanding of the beam losses. These were determined to be 3 ppm through a 2 mm diameter aperture and were maintained during a 7 hour continuous run.
△ Less
Submitted 1 May, 2013;
originally announced May 2013.
-
A gamma- and X-ray detector for cryogenic, high magnetic field applications
Authors:
R. L. Cooper,
R. Alarcon,
M. J. Bales,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
M. S. Dewey,
C. Fu,
T. R. Gentile,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
K. Pulliam,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarg…
▽ More
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.