Skip to main content

Showing 1–4 of 4 results for author: Adya, V B

Searching in archive physics. Search in all archives.
.
  1. arXiv:2401.04940  [pdf, other

    quant-ph physics.optics

    Quantum enhanced balanced heterodyne readout for differential interferometry

    Authors: Daniel W. Gould, Vaishali B. Adya, Sheon S. Y. Chua, Jonas Junker, Dennis Wilken, Terry G. McRae, Bram J. J. Slagmolen, Min Jet Yap, Robert L. Ward, Michèle Heurs, David E. McClelland

    Abstract: Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, spectrally entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this paper, we experimentally demonstrate quantum-enhanced heterodyne readout of two spat… ▽ More

    Submitted 6 May, 2024; v1 submitted 10 January, 2024; originally announced January 2024.

    Comments: 7 pages, 3 figures, 2 table

  2. arXiv:1711.05439  [pdf, ps, other

    physics.ins-det physics.geo-ph

    Huddle test measurement of a near Johnson noise limited geophone

    Authors: R. Kirchhoff, C. M. Mow-Lowry, V. B. Adya, G. Bergmann, S. Cooper, M. M. Hanke, P. Koch, S. M. Koehlenbeck, J. Lehmann, P. Oppermann, J. Woehler, D. S. Wu, H. Lueck, K. A. Strain

    Abstract: In this paper the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground sig… ▽ More

    Submitted 15 November, 2017; originally announced November 2017.

    Comments: 7 pages, 2 supplementary materials, 8 figures plus 2 supplementary material figures, accepted for publication in Review of Scientific Instruments

  3. Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system

    Authors: G Bergmann, C M Mow-Lowry, V B Adya, A Bertolini, M M Hanke, R Kirchhoff, S M Köhlenbeck, G Kühn, P Oppermann, A Wanner, T Westphal, J Wöhler, D S Wu, H Lück, K A Strain, K Danzmann

    Abstract: The 10m Prototype facility at the Albert-Einstein-Institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI Seismic-Attenuation-System (AEI-SAS) uses mechanical anti-springs in order to achieve resonance frequencies below 0.5Hz. This system provides passive isolation from ground motion by a factor of about 400 in the horizontal direct… ▽ More

    Submitted 10 July, 2017; originally announced July 2017.

    Journal ref: Classical and Quantum Gravity 34.6 (2017): 065002

  4. arXiv:1602.03845  [pdf, ps, other

    gr-qc astro-ph.IM physics.ins-det

    Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914

    Authors: The LIGO Scientific Collaboration, B. P. Abbott, R. Abbott, T. D. Abbott, M. R. Abernathy, K. Ackley, C. Adams, P. Addesso, R. X. Adhikari, V. B. Adya, C. Affeldt, N. Aggarwal, O. D. Aguiar, A. Ain, P. Ajith, B. Allen, P. A. Altin, D. V. Amariutei, S. B. Anderson, W. G. Anderson, K. Arai, M. C. Araya, C. C. Arceneaux, J. S. Areeda, K. G. Arun , et al. (702 additional authors not shown)

    Abstract: In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec… ▽ More

    Submitted 28 February, 2017; v1 submitted 11 February, 2016; originally announced February 2016.

    Comments: 15 pages, 10 figures

    Journal ref: Phys. Rev. D 95, 062003 (2017)