Front-end ASIC for Spectroscopic Readout of Virtual Frisch-Grid CZT Bar Sensors
Authors:
Emerson Vernon,
Gianluigi De Geronimo,
Aleksey Bolotnikov,
Milutin Stanacevic,
Jack Fried,
Luis Ocampo Giraldo,
Kevin Wolniewicz,
Kim Ackley,
Cynthia Salwen,
John Triolo,
Don Pinelli,
Kenny Luong
Abstract:
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at th…
▽ More
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order sha**, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than $\pm$ 1 % with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 x 4 array of 6 mm x 6 mm x 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of $\approx$ 270 rms $e^{-}$ for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8 % FWHM at 238 keV and 0.9 % FWHM at 662 keV.
△ Less
Submitted 2 April, 2019;
originally announced April 2019.
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.