-
Electromagnetic calorimeter time measurement applications in the SND physics analysis
Authors:
N. A. Melnikova,
M. N. Achasov,
A. A. Botov,
V. P. Druzhinin,
L. V. Kardapoltsev,
A. A. Korol,
D. P. Kovrizhin,
S. I. Serednyakov,
I. K. Surin
Abstract:
The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a hodoscopic electromagnetic calorimeter (EMC) with three layers of NaI(Tl) counters. The EMC signal sha** and digitizing electronics based on FADC allow to obtain bo…
▽ More
The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a hodoscopic electromagnetic calorimeter (EMC) with three layers of NaI(Tl) counters. The EMC signal sha** and digitizing electronics based on FADC allow to obtain both the signal amplitude and the arrival time. We describe the EMC signal processing and how the EMC measured time is applied in event reconstruction and physics analysis.
△ Less
Submitted 5 May, 2023;
originally announced May 2023.
-
SND electromagnetic calorimeter time measurement and its applications
Authors:
M. N. Achasov,
A. G. Bogdanchikov,
V. P. Druzhinin,
A. A. Korol,
D. P. Kovrizhin,
N. A. Melnikova,
S. I. Serednyakov,
I. K. Surin,
A. I. Tekut'ev,
Yu. V. Usov,
V. V. Zhulanov
Abstract:
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measureme…
▽ More
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measurement in counters was possible. A new EMC signal sha** and digitizing electronics based on FADC allows us to obtain also the event time structure. The new electronics and supporting software, including digital signal processing algorithms, are used for data taking in the ongoing experiment. We discuss the amplitude and time extraction algorithms, the new system performance on experimental events and physical analysis applications.
△ Less
Submitted 2 June, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
Luminosity measurements for the R scan experiment at BESIII
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (405 additional authors not shown)
Abstract:
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Bei**g Spectrometer (BESIII) at the Bei**g Electron-Positron Collider (BEPCII), the integrated luminosities have been measur…
▽ More
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Bei**g Spectrometer (BESIII) at the Bei**g Electron-Positron Collider (BEPCII), the integrated luminosities have been measured at the different c.m. energies, individually. The results are the important inputs for R value and $J/ψ$ resonance parameter measurements.
△ Less
Submitted 11 February, 2017;
originally announced February 2017.
-
Separation of $e^+e^-\to e^+e^-$ and $e^+e^-\toπ^+π^-$ events using SND detector calorimeter
Authors:
M. N. Achasov,
K. I. Beloborodov,
A. S. Kupich
Abstract:
The technique of discrimination of the $e^+e^-\to e^+e^-$ and $e^+e^-\to π^+π^-$ events in energy range $0.5 < \sqrt{s} < 1$ GeV by energy deposition in the calorimeter of SND detector was developed by applying machine learning method. Identification efficiency for $e^+e^-\to e^+e^-$ and $e^+e^-\to π^+π^-$ events in the range from 99.3 to 99.8 % has been achived.
The technique of discrimination of the $e^+e^-\to e^+e^-$ and $e^+e^-\to π^+π^-$ events in energy range $0.5 < \sqrt{s} < 1$ GeV by energy deposition in the calorimeter of SND detector was developed by applying machine learning method. Identification efficiency for $e^+e^-\to e^+e^-$ and $e^+e^-\to π^+π^-$ events in the range from 99.3 to 99.8 % has been achived.
△ Less
Submitted 26 December, 2016; v1 submitted 23 November, 2016;
originally announced November 2016.
-
Upgrade of Beam Energy Measurement System at BEPC-II
Authors:
Jian-Yong Zhang,
Xiao Cai,
Xiao-Hu Mo,
Di-Zhou Guo,
Jian-Li Wang,
Bai-Qi Liu,
M. N. Achasov,
A. A. Krasnov,
N. Yu. Muchnoi,
E. E. Pyata,
E. V. Mamoshkina,
F. A. Harris
Abstract:
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requ…
▽ More
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.
△ Less
Submitted 27 October, 2015;
originally announced October 2015.
-
The system for delivery of IR laser radiaton into high vacuum
Authors:
E. V. Abakumova,
M. N. Achasov,
A. A. Krasnov,
N. Yu. Muchnoi,
E. E. Pyata
Abstract:
The system for insertion of a laser beam into the vacuum chamber of high-energy storage ring is described. The main part of the system is the high-vacuum viewport for the IR radiation, based on ZnSe or GaAs crystals. The design of the viewports is presented.
The system for insertion of a laser beam into the vacuum chamber of high-energy storage ring is described. The main part of the system is the high-vacuum viewport for the IR radiation, based on ZnSe or GaAs crystals. The design of the viewports is presented.
△ Less
Submitted 1 April, 2015;
originally announced April 2015.
-
Beam energy determination in experiments at electron-positron colliders
Authors:
M. N. Achasov,
N. Yu. Muchnoi
Abstract:
The review of using of compton backscattering method for determination of the beam energy in collider experiments is given.
The review of using of compton backscattering method for determination of the beam energy in collider experiments is given.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.
-
A system of beam energy measurement based on the Compton backscattered laser photons for the VEPP-2000 electron-positron collider
Authors:
E. V. Abakumova,
M. N. Achasov,
D. E. Berkaev,
V. V. Kaminsky,
I. A. Koop,
A. A. Korol,
S. V. Koshuba,
A. A. Krasnov,
N. Yu. Muchnoi,
E. A. Perevedentsev,
E. E. Pyata,
P. Yu. Shatunov,
Yu. M. Shatunov,
D. B. Shwartz
Abstract:
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6\cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering an…
▽ More
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6\cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering and resonance depolarization methods.
△ Less
Submitted 29 October, 2013;
originally announced October 2013.
-
Measurements of Baryon Pair Decays of $χ_{cJ}$ Mesons
Authors:
M. Ablikim,
M. N. Achasov,
O. Albayrak,
D. J. Ambrose,
F. F. An,
Q. An,
J. Z. Bai,
Y. Ban,
J. Becker,
J. V. Bennett,
M. Bertani,
J. M. Bian,
E. Boger,
O. Bondarenko,
I. Boyko,
R. A. Briere,
V. Bytev,
X. Cai,
O. Cakir,
A. Calcaterra,
G. F. Cao,
S. A. Cetin,
J. F. Chang,
G. Chelkov,
G. Chen
, et al. (326 additional authors not shown)
Abstract:
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$,…
▽ More
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$, $(20.8 \pm 1.6 \pm 2.3)\times 10^{-5}$; $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{0}\barΣ^{0})$ = $(47.8 \pm 3.4 \pm 3.9)\times 10^{-5}$, $(3.8 \pm 1.0 \pm 0.5)\times 10^{-5}$, $(4.0 \pm 1.1 \pm 0.5) \times 10^{-5}$; and $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{+}\barΣ^{-})$ = $(45.4 \pm 4.2 \pm 3.0)\times 10^{-5}$, $(5.4 \pm 1.5 \pm 0.5)\times 10^{-5}$, $(4.9 \pm 1.9 \pm 0.7)\times 10^{-5}$, where the first error is statistical and the second is systematic. Upper limits on the branching fractions for the decays of $χ_{c1,2}\rightarrowΣ^{0}\barΣ^{0}$, $Σ^{+}\barΣ^{-}$, are estimated to be $\cal{B}$$(χ_{c1}\rightarrowΣ^{0}\barΣ^{0}) < 6.2\times 10^{-5}$, $\cal{B}$$(χ_{c2}\rightarrowΣ^{0}\barΣ^{0}) < 6.5\times 10^{-5}$, $\cal{B}$$(χ_{c1}\rightarrowΣ^{+}\barΣ^{-}) < 8.7\times 10^{-5}$ and $\cal{B}$$(χ_{c2}\rightarrowΣ^{+}\barΣ^{-}) < 8.8\times 10^{-5}$ at the 90% confidence level.
△ Less
Submitted 4 March, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.
-
Backscattering of Laser Radiation on Ultra-Relativistic Electrons in Transverse Magnetic Field: Evidence of Photon Interference in a MeV Scale
Authors:
E. V. Abakumova,
M. N. Achasov,
D. E. Berkaev,
V. V. Kaminsky,
N. Yu. Muchnoi,
E. A. Perevedentsev,
E. E. Pyata,
Yu. M. Shatunov
Abstract:
The experiment on laser light backscattering on relativistic electrons was carried out at the VEPP-2000 collider. Laser radiation (λ0 10.6 μm) was scattered head-on the 990 MeV electrons inside the dipole magnet, where an electron orbit radius is about 140 cm. The energies of backscattered photons were measured by the HPGe detector. It was observed experimentally that due to the presence of magnet…
▽ More
The experiment on laser light backscattering on relativistic electrons was carried out at the VEPP-2000 collider. Laser radiation (λ0 10.6 μm) was scattered head-on the 990 MeV electrons inside the dipole magnet, where an electron orbit radius is about 140 cm. The energies of backscattered photons were measured by the HPGe detector. It was observed experimentally that due to the presence of magnetic field, energy spectrum of backscattered photons differs from the Klein-Nishina cross section. The explanation of the effect is proposed in terms of classical electrodynamics. Moreover, it appears that the exact QED predictions for the phenomenon were done more than 40 years ago.
△ Less
Submitted 1 November, 2012;
originally announced November 2012.
-
The beam energy measurement system for the Bei**g electron-positron collider
Authors:
E. V. Abakumova,
M. N. Achasov,
V. E. Blinov,
X. Cai,
H. Y. Dong,
C. D. Fu,
F. A. Harris,
V. V. Kaminsky,
A. A. Krasnov,
Q. Liu,
X. H. Mo,
N. Yu. Muchnoi,
I. B. Nikolaev,
Q. Qin,
H. M. Qu,
S. L. Olsen,
E. E. Pyata,
A. G. Shamov,
C. P. Shen,
K. Yu. Todyshev,
G. S. Varner,
Y. F. Wang,
Q. Xiao,
J. Q. Xu,
J. Y. Zhang
, et al. (3 additional authors not shown)
Abstract:
The beam energy measurement system (BEMS) for the upgraded Bei**g electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 \cdot 10^{-5}. The relative uncertainty of the beam's energy spread is about 6 %.
The beam energy measurement system (BEMS) for the upgraded Bei**g electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 \cdot 10^{-5}. The relative uncertainty of the beam's energy spread is about 6 %.
△ Less
Submitted 27 September, 2011;
originally announced September 2011.
-
The beam energy calibration system for the BEPC-II collider
Authors:
M. N. Achasov,
ChengDong Fu,
Xiaohu Mo,
N. Yu. Muchnoi,
Qing Qin,
Huamin Qu,
Yifang Wang,
**qiang Xu
Abstract:
This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Bei**g). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy wit…
▽ More
This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Bei**g). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy with relative accuracy about 3x10^-5.
△ Less
Submitted 1 April, 2008;
originally announced April 2008.
-
Compact vacuum phototriodes for operation in strong magnetic field
Authors:
M. N. Achasov,
B. A. Baryshev,
K. I. Beloborodov,
A. V. Bozhenok,
S. V. Burdin,
V. B. Golubev,
E. E. Pyata,
S. I. Serednyakov,
Z. I. Stepanenko,
Yu. A. Tikhonov,
P. V. Vorobyov
Abstract:
The results of tests of 1'' vacuum phototriodes in a magnetic field up to 4.5 T are presented. It was found that output amplitude decreases by about 6 % per tesla in the magnetic field range from 2.0 to 4.0 T. For devices with an anode mesh pitch of 16$μ$m, the output amplitude at 4.0 T is 30 % lower than that at zero field.
The results of tests of 1'' vacuum phototriodes in a magnetic field up to 4.5 T are presented. It was found that output amplitude decreases by about 6 % per tesla in the magnetic field range from 2.0 to 4.0 T. For devices with an anode mesh pitch of 16$μ$m, the output amplitude at 4.0 T is 30 % lower than that at zero field.
△ Less
Submitted 26 February, 2001;
originally announced February 2001.
-
Spherical Neutral Detector for VEPP-2M collider
Authors:
M. N. Achasov,
V. M. Aulchenko,
S. E. Baru,
K. I. Beloborodov,
A. V. Berdyugin,
A. G. Bogdanchikov,
A. V. Bozhenok,
A. D. Bukin,
D. A. Bukin,
S. V. Burdin,
T. V. Dimova,
S. I. Dolinsky,
A. A. Drozdetsky,
V. P. Druzhinin,
M. S. Dubrovin,
I. A. Gaponenko,
V. B. Golubev,
V. N. Ivanchenko,
A. A. Korol,
S. V. Koshuba,
G. A. Kukartsev,
E. V. Pakhtusova,
V. M. Popov,
A. A. Salnikov,
S. I. Serednyakov
, et al. (7 additional authors not shown)
Abstract:
The Spherical Neutral Detector (SND) operates at VEPP-2M collider in Novosibirsk studying e^+e^- annihilation in the energy range up to 1.4 GeV. Detector consists of a fine granulated spherical scintillation calorimeter with 1632 NaI(Tl) crystals, two cylindrical drift chambers with 10 layers of sense wires, and a muon system made of streamer tubes and plastic scintillation counters. The detecto…
▽ More
The Spherical Neutral Detector (SND) operates at VEPP-2M collider in Novosibirsk studying e^+e^- annihilation in the energy range up to 1.4 GeV. Detector consists of a fine granulated spherical scintillation calorimeter with 1632 NaI(Tl) crystals, two cylindrical drift chambers with 10 layers of sense wires, and a muon system made of streamer tubes and plastic scintillation counters. The detector design, performance, data acquisition and processing are described.
△ Less
Submitted 10 September, 1999;
originally announced September 1999.
-
Energy calibration of the NaI(Tl) calorimeter of the SND detector using $e^+e^- \to e^+e^-$ events
Authors:
M. N. Achasov,
D. A. Bukin,
T. V. Dimova,
V. P. Druzhinin,
V. B. Golubev,
V. N. Ivanchenko,
A. A. Korol
Abstract:
Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.
Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.
△ Less
Submitted 10 June, 1998;
originally announced June 1998.
-
Energy calibration of the NaI(Tl) calorimeter of the SND detector using cosmic muons
Authors:
M. N. Achasov,
A. D. Bukin,
D. A. Bukin,
V. P. Druzhinin,
V. B. Golubev,
V. N. Ivanchenko,
S. V. Koshuba,
S. I. Serednyakov
Abstract:
The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of $5.5 % (σ)$ for 500 MeV photons was achieved.
The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of $5.5 % (σ)$ for 500 MeV photons was achieved.
△ Less
Submitted 25 May, 1998;
originally announced May 1998.