Temperature Dependence of the Electron-Drift Anisotropy and Implications for the Electron-Drift Model
Authors:
Iris Abt,
Chris Gooch,
Felix Hagemann,
Lukas Hauertmann,
David Hervas Aguilar,
Xiang Liu,
Oliver Schulz,
Martin Schuster,
Anna Julia Zsigmond
Abstract:
The electron drift in germanium detectors is modeled making many assumptions. Confronted with data, these assumptions have to be revisited. The temperature dependence of the drift of electrons was studied in detail for an n-type segmented point-contact germanium detector. The detector was mounted in a temperature controlled, electrically cooled cryostat. Surface events were induced with collimated…
▽ More
The electron drift in germanium detectors is modeled making many assumptions. Confronted with data, these assumptions have to be revisited. The temperature dependence of the drift of electrons was studied in detail for an n-type segmented point-contact germanium detector. The detector was mounted in a temperature controlled, electrically cooled cryostat. Surface events were induced with collimated 81 keV photons from a $^{133}$Ba source. A detailed analysis of the rise time of pulses collected in surface scans, performed at different temperatures, is presented. The longitudinal anisotropy of the electron drift decreases with rising temperature. A new approach, making use of designated rise-time windows determined by simulations using SolidStateDetectors.jl, was used to isolate the longitudinal drift of electrons along different axes to quantify this observation. The measured temperature dependence of the longitudinal drift velocities combined with the standard electron drift model as widely used in relevant simulation packages results in unphysical predictions. A first suggestion to modify the electron-drift model is motivated and described. The results of a first implementation of the modified model in SolidStateDetectors.jl are shown. They describe the data reasonably well. A general review of the model and the standard input values for mobilities is suggested.
△ Less
Submitted 9 October, 2022;
originally announced October 2022.
-
Bayesian inference of high-purity germanium detector impurities based on capacitance measurements and machine-learning accelerated capacitance calculations
Authors:
Iris Abt,
Christopher Gooch,
Felix Hagemann,
Lukas Hauertmann,
Xiang Liu,
Oliver Schulz,
Martin Schuster
Abstract:
The impurity density in high-purity germanium detectors is crucial to understand and simulate such detectors. However, the information about the impurities provided by the manufacturer, based on Hall effect measurements, is typically limited to a few locations and comes with a large uncertainty. As the voltage dependence of the capacitance matrix of a detector strongly depends on the impurity dens…
▽ More
The impurity density in high-purity germanium detectors is crucial to understand and simulate such detectors. However, the information about the impurities provided by the manufacturer, based on Hall effect measurements, is typically limited to a few locations and comes with a large uncertainty. As the voltage dependence of the capacitance matrix of a detector strongly depends on the impurity density distribution, capacitance measurements can provide a path to improve the knowledge on the impurities. The novel method presented here uses a machine-learned surrogate model, trained on precise GPU-accelerated capacitance calculations, to perform full Bayesian inference of impurity distribution parameters from capacitance measurements. All steps use open-source Julia software packages. Capacitances are calculated with SolidStateDetectors.jl, machine learning is done with Flux.jl and Bayesian inference performed using BAT.jl. The capacitance matrix of a detector and its dependence on the impurity density is explained and a capacitance bias-voltage scan of an n-type true-coaxial test detector is presented. The study indicates that the impurity density of the test detector also has a radial dependence.
△ Less
Submitted 25 September, 2022;
originally announced September 2022.
-
Identification and simulation of surface alpha events on passivated surfaces of germanium detectors and the influence of metalisation
Authors:
Iris Abt,
Christopher Gooch,
Felix Hagemann,
Lukas Hauertmann,
Xiang Liu,
Oliver Schulz,
Martin Schuster,
Anna Julia Zsigmond
Abstract:
Events from alpha interactions on the surfaces of germanium detectors are a major contribution to the background in germanium-based searches for neutrinoless double-beta decay. Surface events are subject to charge trap**, affecting their pulse shape and reconstructed energy. A study of alpha events on the passivated end-plate of a segmented true-coaxial n-type high-purity germanium detector is p…
▽ More
Events from alpha interactions on the surfaces of germanium detectors are a major contribution to the background in germanium-based searches for neutrinoless double-beta decay. Surface events are subject to charge trap**, affecting their pulse shape and reconstructed energy. A study of alpha events on the passivated end-plate of a segmented true-coaxial n-type high-purity germanium detector is presented. Charge trap** is analysed in detail and an existing pulse-shape analysis technique to identify alpha events is verified with mirror pulses observed in the non-collecting channels of the segmented test detector. The observed radial dependence of charge trap** confirms previous results. A dependence of the probability of charge trap** on the crystal axes is observed for the first time. A first model to describe charge trap** effects within the framework of the simulation software SolidStateDetectors.jl is introduced. The influence of metalisation on events from low-energy gamma interactions close to the passivated surface is also presented.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
A novel wide-angle Compton Scanner setup to study bulk events in germanium detectors
Authors:
I. Abt,
C. Gooch,
F. Hagemann,
L. Hauertmann,
D. Hervas Aguilar,
X. Liu,
O. Schulz,
M. Schuster,
A. J. Zsigmond
Abstract:
A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated setup, the detector under test is irradiated from the top with 661.660 keV gammas, some of which Compton scatter inside the detector. The interaction points in…
▽ More
A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated setup, the detector under test is irradiated from the top with 661.660 keV gammas, some of which Compton scatter inside the detector. The interaction points in the detector can be reconstructed when the scattered gammas are detected with a pixelated camera placed at the side of the detector. The wide range of accepted Compton angles results in shorter measurement times in comparison to similar setups where only perpendicularly scattered gammas are selected by slit collimators. In this paper, the construction of the Compton Scanner, its alignment and the procedure to reconstruct interaction points in the germanium detector are described in detail. The creation of a first pulse shape library for an n-type segmented point-contact germanium detector is described. The spatial reconstruction along the beam axis is validated by a comparison to measured surface pulses. A first comparison of Compton Scanner pulses to simulated pulses is presented to demonstrate the power of the Compton Scanner to test simulation inputs and models.
△ Less
Submitted 7 October, 2022; v1 submitted 7 February, 2022;
originally announced February 2022.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Surface characterization of p-type point contact germanium detectors
Authors:
F. Edzards,
L. Hauertmann,
I. Abt,
C. Gooch,
B. Lehnert,
X. Liu,
S. Mertens,
D. C. Radford,
O. Schulz,
M. Willers
Abstract:
P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0vbb) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors feature an excellent energy resolution, low detection thresholds down to the sub-keV range, and enhanced background rejection capabilities. However, due to thei…
▽ More
P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0vbb) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors feature an excellent energy resolution, low detection thresholds down to the sub-keV range, and enhanced background rejection capabilities. However, due to their large passivated surface, separating the signal readout contact from the bias voltage electrode, PPC detectors are susceptible to surface effects such as charge build-up. A profound understanding of their response to surface events is essential. In this work, the response of a PPC detector to alpha and beta particles hitting the passivated surface was investigated in a multi-purpose scanning test stand. It is shown that the passivated surface can accumulate charges resulting in a radial-dependent degradation of the observed event energy. In addition, it is demonstrated that the pulse shapes of surface alpha events show characteristic features which can be used to discriminate against these events.
△ Less
Submitted 10 September, 2021; v1 submitted 30 May, 2021;
originally announced May 2021.
-
Simulation of semiconductor detectors in 3D with SolidStateDetectors.jl
Authors:
I. Abt,
F. Fischer,
F. Hagemann,
L. Hauertmann,
O. Schulz,
M. Schuster,
A. J. Zsigmond
Abstract:
The open-source software package SolidStateDetectors.jl to calculate the fields and simulate the drifts of charge carriers in solid state detectors, together with the corresponding pulses, is introduced. The package can perform all calculations in full 3D while it can also make use of detector symmetries. The effect of the surroundings of a detector can also be studied. The package is programmed i…
▽ More
The open-source software package SolidStateDetectors.jl to calculate the fields and simulate the drifts of charge carriers in solid state detectors, together with the corresponding pulses, is introduced. The package can perform all calculations in full 3D while it can also make use of detector symmetries. The effect of the surroundings of a detector can also be studied. The package is programmed in the user friendly and performance oriented language Julia, such that 3D field calculations and drift simulations can be executed efficiently and in parallel. While all kinds of semiconductor devices can be simulated, special emphasis is put on germanium detectors. The verification of the package is shown for an n-type segmented point-contact germanium detector. Additional features of SolidStateDetectors.jl planned for the near future are listed.
△ Less
Submitted 25 November, 2021; v1 submitted 31 March, 2021;
originally announced April 2021.
-
Usage of PEN as self-vetoing structural material in low background experiments
Authors:
I. Abt,
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart,
K. Gusev,
B. Hackett,
C. Hayward,
R. Hodak,
P. Krause,
B. Majorovits,
L. Manzanillas,
D. Muenstermann,
R. Pjatkan,
M. Pohl,
R. Rouhana,
D. Radford,
E. Rukhadze,
N. Rumyantseva,
I. Schilling,
S. Schoenert,
O. Schulz,
M. Schwarz,
M. Stommel,
J. Weingarten
Abstract:
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background exper…
▽ More
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background experiments. One possible application are holders for germanium detectors operating in cryogenic liquids (LAr, LN2). Such structures can help to reject surface and external backgrounds, boosting the sensitivity of experiments. In this contribution, the R\&D on PEN is outlined and an evaluation of the first production of PEN structures for the LEGEND-200 experiment is reported.
△ Less
Submitted 9 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
Characterization of High-Purity Germanium Detectors with Amorphous Germanium Contacts in Cryogenic Liquids
Authors:
R. Panth,
J. Liu,
I. Abt,
X. Liu,
O. Schulz,
W. -Z. Wei,
H. Mei,
D. -M. Mei,
G. -J. Wang
Abstract:
For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fuer Physics in Munich. The detectors were fabricated at the Lawrence Berkeley National Laboratory and the University of South Dakota, using crystals grown at the University of South Dakota…
▽ More
For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fuer Physics in Munich. The detectors were fabricated at the Lawrence Berkeley National Laboratory and the University of South Dakota, using crystals grown at the University of South Dakota. They survived long-distance transportation and multiple thermal cycles in both cryogenic liquids and showed reasonable leakage currents and spectroscopic performance. Also discussed are the pros and cons of using thin amorphous semiconductor materials as an alternative contact technology in large-scale germanium experiments searching for physics beyond the Standard Model.
△ Less
Submitted 3 August, 2020; v1 submitted 30 March, 2020;
originally announced March 2020.
-
Characterisation of an n-type segmented BEGe detector
Authors:
I. Abt,
A. Caldwell,
B. Donmez,
C. Etrillard,
C. Gooch,
L. Hauertmann,
M. O. Lampert,
H. Liao,
X. Liu,
H. Ma,
B. Majorovits,
O. Schulz,
M. Schuster
Abstract:
A four-fold segmented n-type point-contact "Broad Energy" high-purity germanium detector, SegBEGe, has been characterised at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are described and first measurements concerning the detector properties are presented. The possibility to use mirror pulses to determine source positions is discussed as well as charge los…
▽ More
A four-fold segmented n-type point-contact "Broad Energy" high-purity germanium detector, SegBEGe, has been characterised at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are described and first measurements concerning the detector properties are presented. The possibility to use mirror pulses to determine source positions is discussed as well as charge losses observed close to the core contact.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Direct measurement of neutrons induced in lead by cosmic muons at a shallow underground site
Authors:
Qiang Du,
Iris Abt,
Anton Empl,
Chris Gooch,
Raphael Kneissl,
Shin Ted LIN,
Bela Majorovits,
Matteo Palermo,
Oliver Schulz,
Li Wang,
Qian YUE,
Anna Julia Zsigmond
Abstract:
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutr…
▽ More
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutrons were detected through neutron capture and neutron-induced nuclear recoil signals in the liquid scintillator detector. Results on the rates of observed neutron captures and nuclear recoils are presented and compared to predictions from GEANT4-9.6 and GEANT4-10.3. The predicted rates are significantly too low for both versions of GEANT4. For neutron capture events, the observation exceeds the predictions by factors of $ 1.65\,\pm\,0.02\,\textrm{(stat.)}\,\pm\,0.07\,\textrm{(syst.)} $ and $ 2.58\,\pm\,0.03\,\textrm{(stat.)}\,\pm\,0.11\,\textrm{(syst.)} $ for GEANT4-9.6 and GEANT4-10.3, respectively. For neutron nuclear recoil events, which require neutron energies above approximately 5 MeV, the factors are even larger, $ 2.22\,\pm\,0.05\,\textrm{(stat.)}\,\pm\,0.25\,\textrm{(syst.)} $ and $ 3.76\,\pm\,0.09\,\textrm{(stat.)}\,\pm\,0.41\,\textrm{(syst.)} $, respectively. Also presented is the first statistically significant measurement of the spectrum of neutrons induced by cosmic muons in lead between 5 and 40 MeV. It was obtained by unfolding the nuclear recoil spectrum. The observed neutron spectrum is harder than predicted by GEANT4. An investigation of the distribution of the time difference between muon tags and nuclear recoil signals confirms the validity of the unfolding procedure and shows that GEANT4 cannot properly describe the time distribution of nuclear recoil events. In general, the description of the data is worse for GEANT4-10.3 than for GEANT4-9.6.
△ Less
Submitted 7 May, 2018; v1 submitted 15 January, 2018;
originally announced January 2018.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Alpha-event and surface characterisation in segmented true-coaxial HPGe detectors
Authors:
Iris Abt,
Lucia Garbini,
Chris Gooch,
Sabine Irlbeck,
Xiang Liu,
Matteo Palermo,
Oliver Schulz
Abstract:
A detailed study of alpha interactions on the passivation layer on the end-plate of a true-coaxial high-purity germanium detector is presented. The observation of alpha events on such a surface indicates an unexpectedly thin so-called "dead layer" of less than 20 μm thickness. In addition, the influence of the metalisation close to the end-plate on the time evolution of the output pulses is discus…
▽ More
A detailed study of alpha interactions on the passivation layer on the end-plate of a true-coaxial high-purity germanium detector is presented. The observation of alpha events on such a surface indicates an unexpectedly thin so-called "dead layer" of less than 20 μm thickness. In addition, the influence of the metalisation close to the end-plate on the time evolution of the output pulses is discussed. The results indicate that alpha contamination can result in events which could be mistaken as signals for neutrinoless double beta decay and provide some guidance on how to prevent this.
△ Less
Submitted 28 January, 2018; v1 submitted 1 November, 2016;
originally announced November 2016.
-
The Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX
Authors:
I. Abt,
A. Caldwell,
C. Carissimo,
C. Gooch,
R. Kneissl,
J. Langford,
X. Liu,
B. Majorovits,
M. Palermo,
O. Schulz,
L. Vanhoefer
Abstract:
A new experiment to quantitatively measure neutrons induced by cosmic-ray muons in selected high-Z materials is introduced. The design of the Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX, and the results from its first data taking period are presented as well as future plans. Neutron production in high-Z materials is of particular interest as such materials are used for shielding in…
▽ More
A new experiment to quantitatively measure neutrons induced by cosmic-ray muons in selected high-Z materials is introduced. The design of the Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX, and the results from its first data taking period are presented as well as future plans. Neutron production in high-Z materials is of particular interest as such materials are used for shielding in low-background experiments. The design of next-generation large-scale experiments searching for neutrinoless double beta decay or direct interactions of dark matter requires reliable Monte Carlo simulations of background induced by muon interactions. The first five months of operation already provided a valuable data set on neutron production and neutron transport in lead. A first round of comparisons between MINIDEX data and Monte Carlo predictions obtained with two GEANT4- based packages is presented. The rate of muon-induced events is overall a factor three to four higher in data than predicted by the Monte Carlo packages. In addition, the time evolution of the muon-induced signal is not well described by the simulations.
△ Less
Submitted 5 October, 2016;
originally announced October 2016.
-
The GALATEA Test-Facility for High Purity Germanium Detectors
Authors:
I. Abt,
A. Caldwell,
B. Doenmez,
L. Garbini,
S. Irlbeck,
B. Majorovits,
M. Palermo,
O. Schulz,
H. Seitz,
F. Stelzer
Abstract:
GALATEA is a test facility designed to investigate bulk and surface effects in high purity germanium detectors. A vacuum tank houses an infrared screened volume with a cooled detector inside. A system of three stages allows an almost complete scan of the detector. The main feature of GALATEA is that there is no material between source and detector. This allows the usage of alpha and beta sources a…
▽ More
GALATEA is a test facility designed to investigate bulk and surface effects in high purity germanium detectors. A vacuum tank houses an infrared screened volume with a cooled detector inside. A system of three stages allows an almost complete scan of the detector. The main feature of GALATEA is that there is no material between source and detector. This allows the usage of alpha and beta sources as well as of a laser beam to study surface effects. A 19-fold segmented true-coaxial germanium detector was used for commissioning.
△ Less
Submitted 9 February, 2015; v1 submitted 1 September, 2014;
originally announced September 2014.
-
Aluminum as a source of background in low background experiments
Authors:
B. Majorovits,
I. Abt,
M. Laubenstein,
O. Volynets
Abstract:
Neutrinoless double beta decay would be a key to understanding the nature of neutrino masses. The next generation of High Purity Germanium experiments will have to be operated with a background rate of better than 10^-5 counts/(kg y keV) in the region of interest around the Q value of the decay. Therefore, so far irrelevant sources of background have to be considered. The metalization of the surfa…
▽ More
Neutrinoless double beta decay would be a key to understanding the nature of neutrino masses. The next generation of High Purity Germanium experiments will have to be operated with a background rate of better than 10^-5 counts/(kg y keV) in the region of interest around the Q value of the decay. Therefore, so far irrelevant sources of background have to be considered. The metalization of the surface of germanium detectors is in general done with aluminum. The background from the decays of 22Na, 26Al, 226Ra and 228Th introduced by this metalization is discussed. It is shown that only a special selection of aluminum can keep these background contributions acceptable.
△ Less
Submitted 18 May, 2011;
originally announced May 2011.
-
Pulse shape simulation for segmented true-coaxial HPGe detectors
Authors:
I. Abt,
A. Caldwell,
D. Lenz,
J. Liu,
X. Liu,
B. Majorovits
Abstract:
A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pul…
▽ More
A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pulses, obtained from an 18-fold segmented detector operated inside a cryogenic test facility, are presented.
△ Less
Submitted 6 April, 2010;
originally announced April 2010.