-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
The Muon System of the Run II D0 Detector
Authors:
The D0 Muon Group,
V. M. Abazov
Abstract:
We describe the design, construction and performance of the upgraded DO muon system for Run II of the Fermilab Tevatron collider. Significant improvements have been made to the major subsystems of the DO muon detector: trigger scintillation counters, tracking detectors, and electronics. The Run II central muon detector has a new scintillation counter system inside the iron toroid and an improved…
▽ More
We describe the design, construction and performance of the upgraded DO muon system for Run II of the Fermilab Tevatron collider. Significant improvements have been made to the major subsystems of the DO muon detector: trigger scintillation counters, tracking detectors, and electronics. The Run II central muon detector has a new scintillation counter system inside the iron toroid and an improved scintillation counter system outside the iron toroid. In the forward region, new scintillation counter and tracking systems have been installed. Extensive shielding has been added in the forward region. A large fraction of the muon system electronics is also new.
△ Less
Submitted 17 March, 2005;
originally announced March 2005.