-
Larmor Power Limit for Cyclotron Radiation of Relativistic Particles in a Waveguide
Authors:
N. Buzinsky,
R. J. Taylor,
W. Byron,
W. DeGraw,
B. Dodson,
M. Fertl,
A. García,
A. P. Goodson,
B. Graner,
H. Harrington,
L. Hayen,
L. Malavasi,
D. McClain,
D. Melconian,
P. Müller,
E. Novitski,
N. S. Oblath,
R. G. H. Robertson,
G. Rybka,
G. Savard,
E. Smith,
D. D. Stancil,
D. W. Storm,
H. E. Swanson,
J. R. Tedeschi
, et al. (3 additional authors not shown)
Abstract:
Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-dec…
▽ More
Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-decay spectroscopy of ${}^6\textrm{He}$ and ${}^{19}\textrm{Ne}$. Having demonstrated the first observation of individual, high-energy (0.1 -- 2.5 MeV) positrons and electrons via their cyclotron radiation, the experiment provides a novel window into the radiation of relativistic charged particles in a waveguide via the time-derivative (slope) of the cyclotron radiation frequency, $\mathrm{d}f_\textrm{c}/\mathrm{d}t$. We show that analytic predictions for the total cyclotron radiation power emitted by a charged particle in circular and rectangular waveguides are approximately consistent with the Larmor formula, each scaling with the Lorentz factor of the underlying $e^\pm$ as $γ^4$. This hypothesis is corroborated with experimental CRES slope data.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US
Authors:
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
D. H. Beck,
T. Bhattacharya,
M. Blatnik,
T. J. Bowles,
J. D. Bowman,
J. Brewington,
L. J. Broussard,
A. Bryant,
J. F. Burdine,
J. Caylor,
Y. Chen,
J. H. Choi,
L. Christie,
T. E. Chupp,
V. Cianciolo,
V. Cirigliano,
S. M. Clayton,
B. Collett,
C. Crawford,
W. Dekens,
M. Demarteau,
D. DeMille
, et al. (66 additional authors not shown)
Abstract:
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadr…
▽ More
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$τ$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $θ$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Recoil-Order and Radiative Corrections to the aCORN Experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
B. Collett,
M. S. Dewey,
T. R. Gentile,
F. Gluck,
M. T. Hassan,
G. L. Jones,
A. Komives,
J. S. Nico,
E. J. Stephenson
Abstract:
The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is…
▽ More
The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is $\overline{a} = -0.10779 \pm 0.00125\, ({\rm stat}) \pm 0.00133\, ({\rm sys})$, averaged over the full Fermi neutron beta spectrum. The corresponding corrected result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2712 \pm 0.0061$. This improves agreement with previous $a$-coefficient experiments, in particular the 2020 aSPECT result
△ Less
Submitted 1 March, 2024; v1 submitted 26 June, 2023;
originally announced June 2023.
-
Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan
Authors:
B. Acharya,
C. Adams,
A. A. Aleksandrova,
K. Alfonso,
P. An,
S. Baeßler,
A. B. Balantekin,
P. S. Barbeau,
F. Bellini,
V. Bellini,
R. S. Beminiwattha,
J. C. Bernauer,
T. Bhattacharya,
M. Bishof,
A. E. Bolotnikov,
P. A. Breur,
M. Brodeur,
J. P. Brodsky,
L. J. Broussard,
T. Brunner,
D. P. Burdette,
J. Caylor,
M. Chiu,
V. Cirigliano,
J. A. Clark
, et al. (154 additional authors not shown)
Abstract:
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recom…
▽ More
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recommendations and justifies them in detail.
△ Less
Submitted 6 April, 2023;
originally announced April 2023.
-
Comments on Systematic Effects in the NIST Beam Neutron Lifetime Experiment
Authors:
F. E. Wietfeldt,
R. Biswas,
J. Caylor,
B. Crawford,
M. S. Dewey,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
W. M. Snow,
J. Zuchegno
Abstract:
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the is…
▽ More
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the issues raised in Serebrov, et al lead us to alter the value of the neutron lifetime reported previously.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
First observation of cyclotron radiation from MeV-scale ${\rm e}^{pm}$ following nuclear beta decay
Authors:
W. Byron,
H. Harrington,
R. J. Taylor,
W. DeGraw,
N. Buzinsky,
B. Dodson,
M. Fertl,
A. Garcia,
G. Garvey,
B. Graner,
M. Guigue,
L. Hayen,
X. Huyan,
K. S. Khaw,
K. Knutsen,
D. McClain,
D. Melconian,
P. Mueller,
E. Novitski,
N. S. Oblath,
R. G. H. Robertson,
G. Rybka,
G. Savard,
E. Smith,
D. D. Stancil
, et al. (8 additional authors not shown)
Abstract:
We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles in a magnetic field is used to determine the beta energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy…
▽ More
We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles in a magnetic field is used to determine the beta energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of beta^-s from 6He and beta^+s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for beta spectroscopy over the full (MeV) energy range. This work is an important benchmark for the practical application of the CRES technique to a variety of nuclei, in particular, opening its reach to searches for evidence of new physics beyond the TeV scale via precision beta-decay measurements.
△ Less
Submitted 3 July, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment
Authors:
M. T. Hassan,
W. A. Byron,
G. Darius,
C. DeAngelis,
F. E. Wietfeldt,
B. Collett,
G. L. Jones,
A. Komives,
G. Noid,
E. J. Stephenson,
F. Bateman,
M. S. Dewey,
T. R. Gentile,
M. P. Mendenhall,
J. S. Nico
Abstract:
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on t…
▽ More
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Neutron Polarimetry Using a Polarized 3He Cell for the aCORN Experiment
Authors:
B. C. Schafer,
W. A. Byron,
W. C. Chen,
B. Collett,
M. S. Dewey,
T. R. Gentile,
Md. T. Hassan,
G. L. Jones,
A. Komives,
F. E. Wietfeldt
Abstract:
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The depend…
▽ More
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The polarization of the NG-C beamline was found to be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.
△ Less
Submitted 25 September, 2020; v1 submitted 8 September, 2020;
originally announced September 2020.
-
A Comment on "The possible explanation of neutron lifetime beam anomaly" by A. P. Serebrov, et al
Authors:
F. E. Wietfeldt,
R. Biswas,
R. W. Haun,
M. S. Dewey,
J. Caylor,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
B. Crawford,
W. M. Snow
Abstract:
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
A Precision Measurement of the Neutron Scattering Length of He-4 Using Neutron Interferometry
Authors:
R. Haun,
F. E. Wietfeldt,
M. Arif,
M. G. Huber,
T. C. Black,
B. Heacock,
D. A. Pushin,
C. B. Shahi
Abstract:
We report a 0.08 % measurement of the bound neutron scattering length of $^4$He using neutron interferometry. The result is $b = (3.0982 \pm 0.0021 \mbox{ [stat]} \pm 0.0014 \mbox{ [sys]}) \mbox{ fm}$. The corresponding free atomic scattering length is $a = (2.4746 \pm 0.0017 \mbox{ [stat]} \pm 0.0011 \mbox{ [sys]}) \mbox{ fm}$. With this result the world average becomes $b = (3.0993 \pm 0.0025)$…
▽ More
We report a 0.08 % measurement of the bound neutron scattering length of $^4$He using neutron interferometry. The result is $b = (3.0982 \pm 0.0021 \mbox{ [stat]} \pm 0.0014 \mbox{ [sys]}) \mbox{ fm}$. The corresponding free atomic scattering length is $a = (2.4746 \pm 0.0017 \mbox{ [stat]} \pm 0.0011 \mbox{ [sys]}) \mbox{ fm}$. With this result the world average becomes $b = (3.0993 \pm 0.0025)$ fm, a 2 % downward shift and a reduction in uncertainty by more than a factor of six. Our result is in disagreement with a previous neutron interferometric measurement but is in good agreement with earlier measurements using neutron transmission.
△ Less
Submitted 30 October, 2019;
originally announced October 2019.
-
Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
G. Darius,
C. R. DeAngelis,
M. T. Hassan,
M. S. Dewey,
M. P. Mendenhall,
J. S. Nico,
B. Collett,
G. L. Jones,
A. Komives,
E. J. Stephenson
Abstract:
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertaint…
▽ More
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
Precision Measurement of the Radiative $\Beta$ Decay of the Free Neutron
Authors:
M. J. Bales,
R. Alarcon,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
M. S. Dewey,
S. Gardner,
T. R. Gentile,
D. He,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was…
▽ More
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
△ Less
Submitted 26 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
The Neutron Lifetime
Authors:
F. E. Wietfeldt
Abstract:
The decay of the free neutron into a proton, electron, and antineutrino is the prototype semileptonic weak decay and the simplest example of nuclear beta decay. The nucleon vector and axial vector weak coupling constants G_V and G_A determine the neutron lifetime as well as the strengths of weak interaction processes involving free neutrons and protons that are important in astrophysics, cosmology…
▽ More
The decay of the free neutron into a proton, electron, and antineutrino is the prototype semileptonic weak decay and the simplest example of nuclear beta decay. The nucleon vector and axial vector weak coupling constants G_V and G_A determine the neutron lifetime as well as the strengths of weak interaction processes involving free neutrons and protons that are important in astrophysics, cosmology, solar physics and neutrino detection. In combination with a neutron decay angular correlation measurement, the neutron lifetime can be used to determine the first element of the CKM matrix Vud. Unfortunately the two main experimental methods for measuring the neutron lifetime currently disagree by almost 4 sigma. I will present a brief review of the status of the neutron lifetime and prospects for the future.
△ Less
Submitted 13 November, 2014;
originally announced November 2014.
-
Determination of the Free Neutron Lifetime
Authors:
J. David Bowman,
L. J. Broussard,
S. M. Clayton,
M. S. Dewey,
N. Fomin,
K. B. Grammer,
G. L. Greene,
P. R. Huffman,
A. T. Holley,
G. L. Jones,
C. -Y. Liu,
M. Makela,
M. P. Mendenhall,
C. L. Morris,
J. Mulholland,
K. M. Nollett,
R. W. Pattie, Jr.,
S. Penttila,
M. Ramsey-Musolf,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
W. M. Snow,
A. Steyerl,
F. E. Wietfeldt
, et al. (2 additional authors not shown)
Abstract:
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve bot…
▽ More
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
Neutron interferometric measurement of the scattering length difference between the triplet and singlet states of n-$^3$He
Authors:
M. G. Huber,
M. Arif,
W. C. Chen,
T. R. Gentile,
D. S. Hussey,
T. C. Black,
D. A. Pushin,
C. B. Shahi,
F. E. Wietfeldt,
L. Yang
Abstract:
We report a determination of the n-$^3$He scattering length difference $Δb^{\prime} = b_{1}^{\prime}-b_{0}^{\prime} = $ ($-5.411$ $\pm$ $0.031$ (statistical) $\pm$ $0.039$ (systematic)) fm between the triplet and singlet states using a neutron interferometer. This revises our previous result $Δb^{\prime} = $ (-5.610 $\pm$ $0.027$ (statistical) $\pm$ $0.032$ (systematic) fm obtained using the same…
▽ More
We report a determination of the n-$^3$He scattering length difference $Δb^{\prime} = b_{1}^{\prime}-b_{0}^{\prime} = $ ($-5.411$ $\pm$ $0.031$ (statistical) $\pm$ $0.039$ (systematic)) fm between the triplet and singlet states using a neutron interferometer. This revises our previous result $Δb^{\prime} = $ (-5.610 $\pm$ $0.027$ (statistical) $\pm$ $0.032$ (systematic) fm obtained using the same technique in 2008. This revision is due to a re-analysis of the 2008 experiment that includes a more robust treatment of the phase shift caused by magnetic field gradients near the $^3$He cell. Furthermore, we more than doubled our original data set from 2008 by acquiring six months of additional data in 2013. Both the new data set and a re-analysis of the older data are in good agreement. Scattering lengths of low Z isotopes are valued for use in few-body nuclear effective field theories, provide important tests of modern nuclear potential models and in the case of $^3$He aid in the interpretation of neutron scattering from quantum liquids. The difference $Δb^{\prime}$ was determined by measuring the relative phase shift between two incident neutron polarizations caused by the spin-dependent interaction with a polarized $^3$He target. The target $^3$He gas was sealed inside a small, flat windowed glass cell that was placed in one beam path of the interferometer. The relaxation of $^3$He polarization was monitored continuously with neutron transmission measurements. The neutron polarization and spin flipper efficiency were determined separately using $^3$He analyzers and two different polarimetry analysis methods. A summary of the measured scattering lengths for n-$^3$He with a comparison to nucleon interaction models is given.
△ Less
Submitted 13 March, 2023; v1 submitted 30 September, 2014;
originally announced September 2014.
-
Improved Determination of the Neutron Lifetime
Authors:
A. T. Yue,
M. S. Dewey,
D. M. Gilliam,
G. L. Greene,
A. B. Laptev,
J. S. Nico,
W. M. Snow,
F. E. Wietfeldt
Abstract:
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged par…
▽ More
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we have measured the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally-absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but was measured with a precision of 0.057 %, which represents a five-fold improvement in the uncertainty. We have verified the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is $τ_n = (887.7 \pm 1.2 [\textrm{stat}] \pm 1.9 [\textrm{syst}])$ s.
△ Less
Submitted 27 November, 2013; v1 submitted 10 September, 2013;
originally announced September 2013.
-
A gamma- and X-ray detector for cryogenic, high magnetic field applications
Authors:
R. L. Cooper,
R. Alarcon,
M. J. Bales,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
M. S. Dewey,
C. Fu,
T. R. Gentile,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
K. Pulliam,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarg…
▽ More
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.
-
Search for a T-odd, P-even Triple Correlation in Neutron Decay
Authors:
T. E. Chupp,
R. L. Cooper,
K. P. Coulter,
S. J. Freedman,
B. K. Fujikawa,
A. García,
G. L. Jones,
H. P. Mumm,
J. S. Nico,
A. K. Thompson,
C. A. Trull,
F. E. Wietfeldt,
J. F. Wilkerson
Abstract:
Background: Time-reversal-invariance violation, or equivalently CP violation, may explain the observed cosmological baryon asymmetry as well as signal physics beyond the Standard Model. In the decay of polarized neutrons, the triple correlation D<J_{n}>\cdot(p_{e}\timesp_ν) is a parity-even, time-reversal- odd observable that is uniquely sensitive to the relative phase of the axial-vector amplitud…
▽ More
Background: Time-reversal-invariance violation, or equivalently CP violation, may explain the observed cosmological baryon asymmetry as well as signal physics beyond the Standard Model. In the decay of polarized neutrons, the triple correlation D<J_{n}>\cdot(p_{e}\timesp_ν) is a parity-even, time-reversal- odd observable that is uniquely sensitive to the relative phase of the axial-vector amplitude with respect to the vector amplitude. The triple correlation is also sensitive to possible contributions from scalar and tensor amplitudes. Final-state effects also contribute to D at the level of 1e-5 and can be calculated with a precision of 1% or better. Purpose: We have improved the sensitivity to T-odd, P-even interactions in nuclear beta decay. Methods: We measured proton-electron coincidences from decays of longitudinally polarized neutrons with a highly symmetric detector array designed to cancel the time-reversal-even, parity-odd Standard-Model contributions to polarized neutron decay. Over 300 million proton-electron coincidence events were used to extract D and study systematic effects in a blind analysis. Results: We find D = [-0.94\pm1.89(stat)\pm0.97(sys)]e-4. Conclusions: This is the most sensitive measurement of D in nuclear beta decay. Our result can be interpreted as a measurement of the phase of the ratio of the axial-vector and vector coupling constants (CA/CV= |λ|exp(iφ_AV)) with φ_AV = 180.012° \pm0.028° (68% confidence level) or to constrain time-reversal violating scalar and tensor interactions that arise in certain extensions to the Standard Model such as leptoquarks. This paper presents details of the experiment, analysis, and systematic- error corrections.
△ Less
Submitted 31 May, 2012; v1 submitted 30 May, 2012;
originally announced May 2012.
-
A New Limit on Time-Reversal Violation in Beta Decay
Authors:
H. P. Mumm,
T. E. Chupp,
R. L. Cooper,
K. P. Coulter,
S. J. Freedman,
B. K. Fujikawa,
A. Garcia,
G. L. Jones,
J. S. Nico,
A. K. Thompson,
C. A. Trull,
J. F. Wilkerson,
F. E. Wietfeldt
Abstract:
We report the results of an improved determination of the triple correlation $D P \cdot(p_{e}\times p_ν)$ that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the Standard Model. Our result is $D=(-0.96\pm 1.89 (stat)\pm 1.01 (sys))\times 10^{-4}$. The corresponding phase between g_A and g_V is…
▽ More
We report the results of an improved determination of the triple correlation $D P \cdot(p_{e}\times p_ν)$ that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the Standard Model. Our result is $D=(-0.96\pm 1.89 (stat)\pm 1.01 (sys))\times 10^{-4}$. The corresponding phase between g_A and g_V is $φ_{AV} = 180.013^\circ\pm0.028^\circ$ (68 % confidence level). This result represents the most sensitive measurement of D in beta decay.
△ Less
Submitted 26 April, 2011; v1 submitted 14 April, 2011;
originally announced April 2011.
-
Precision Measurement of the n-3He Incoherent Scattering Length Using Neutron Interferometry
Authors:
M. G. Huber,
M. Arif,
T. C. Black,
W. C. Chen,
T. R. Gentile,
D. S. Hussey,
D. Pushin,
F. E. Wietfeldt,
L. Yang
Abstract:
We report the first measurement of the low-energy neutron-$^3$He incoherent scattering length using neutron interferometry: $b_i' = (-2.512\pm 0.012{statistical}\pm0.014{systematic})$ fm. This is in good agreement with a recent calculation using the AV18+3N potential. The neutron-$^3$He scattering lengths are important for testing and develo** nuclear potential models that include three nucleo…
▽ More
We report the first measurement of the low-energy neutron-$^3$He incoherent scattering length using neutron interferometry: $b_i' = (-2.512\pm 0.012{statistical}\pm0.014{systematic})$ fm. This is in good agreement with a recent calculation using the AV18+3N potential. The neutron-$^3$He scattering lengths are important for testing and develo** nuclear potential models that include three nucleon forces, effective field theories for few-body nuclear systems, and neutron scattering measurements of quantum excitations in liquid helium. This work demonstrates the first use of a polarized nuclear target in a neutron interferometer.
△ Less
Submitted 12 May, 2009; v1 submitted 12 September, 2008;
originally announced September 2008.
-
Measuring the Neutron's Mean Square Charge Radius Using Neutron Interferometry
Authors:
F. E. Wietfeldt,
M. Huber,
T. C. Black,
H. Kaiser,
M. Arif,
D. L. Jacobson,
S. A. Werner
Abstract:
The neutron is electrically neutral, but its substructure consists of charged quarks so it may have an internal charge distribution. In fact it is known to have a negative mean square charge radius (MSCR), the second moment of the radial charge density. In other words the neutron has a positive core and negative skin. In the first Born approximation the neutron MSCR can be simply related to the…
▽ More
The neutron is electrically neutral, but its substructure consists of charged quarks so it may have an internal charge distribution. In fact it is known to have a negative mean square charge radius (MSCR), the second moment of the radial charge density. In other words the neutron has a positive core and negative skin. In the first Born approximation the neutron MSCR can be simply related to the neutron-electron scattering length b_ne. In the past this important quantity has been extracted from the energy dependence of the total transmission cross-section of neutrons on high-Z targets, a very difficult and complicated process. A few years ago S.A. Werner proposed a novel approach to measuring b_ne from the neutron's dynamical phase shift in a perfect crystal close to the Bragg condition. We are conducting an experiment based on this method at the NIST neutron interferometer which may lead to a five-fold improvement in precision of b_ne and hence the neutron MSCR.
△ Less
Submitted 14 September, 2005;
originally announced September 2005.
-
Measurement of the Neutron Lifetime by Counting Trapped Protons in a Cold Neutron Beam
Authors:
J. S. Nico,
M. S. Dewey,
D. M. Gilliam,
F. E. Wietfeldt,
X. Fei,
W. M. Snow,
G. L. Greene,
J. Pauwels,
R. Eykens,
A. Lamberty,
J. Van Gestel,
R. D. Scott
Abstract:
A measurement of the neutron lifetime $τ_{n}$ performed by the absolute counting of in-beam neutrons and their decay protons has been completed. Protons confined in a quasi-Penning trap were accelerated onto a silicon detector held at a high potential and counted with nearly unit efficiency. The neutrons were counted by a device with an efficiency inversely proportional to neutron velocity, whic…
▽ More
A measurement of the neutron lifetime $τ_{n}$ performed by the absolute counting of in-beam neutrons and their decay protons has been completed. Protons confined in a quasi-Penning trap were accelerated onto a silicon detector held at a high potential and counted with nearly unit efficiency. The neutrons were counted by a device with an efficiency inversely proportional to neutron velocity, which cancels the dwell time of the neutron beam in the trap. The result is $τ_{n} = (886.6\pm1.2{\rm [stat]}\pm3.2{\rm [sys]})$ s, which is the most precise measurement of the lifetime using an in-beam method. The systematic uncertainty is dominated by neutron counting, in particular the mass of the deposit and the $^{6}$Li({\it{n,t}}) cross section. The measurement technique and apparatus, data analysis, and investigation of systematic uncertainties are discussed in detail.
△ Less
Submitted 19 November, 2004;
originally announced November 2004.
-
emiT: an apparatus to test time reversal invariance in polarized neutron decay
Authors:
H. P. Mumm,
A. Garcia,
L. Grout,
M. Howe,
L. P. Parazzoli,
R. G. H. Robertson,
K. M. Sundqvist,
J. F. Wilkerson,
S. J. Freedman,
B. K. Fujikawa,
L. J. Lising,
M. S. Dewey,
J. S. Nico,
A. K. Thompson,
T. E. Chupp,
R. L. Cooper,
K. P. Coulter,
S. R. Hwang,
R. C. Welsh,
L. J. Broussard,
C. A. Trull,
F. E. Wietfeldt,
G. L. Jones
Abstract:
We describe an apparatus used to measure the triple-correlation term (\D \hatσ_n\cdot p_e\times p_ν) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons pas…
▽ More
We describe an apparatus used to measure the triple-correlation term (\D \hatσ_n\cdot p_e\times p_ν) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons passes through the detector chamber, where a small fraction beta-decay. The final-state protons are accelerated and focused onto arrays of cooled semiconductor diodes, while the coincident electrons are detected using panels of plastic scintillator. Details regarding the design and performance of the proton detectors, beta detectors and the electronics used in the data collection system are presented. The neutron beam characteristics, the spin-transport magnetic fields, and polarization measurements are also described.
△ Less
Submitted 9 February, 2004;
originally announced February 2004.
-
A Backscatter-Suppressed Beta Spectrometer for Neutron Decay Studies
Authors:
F. E. Wietfeldt,
C. Trull,
R. Anderman,
F. B. Bateman,
M. S. Dewey,
A. Komives,
A. K. Thompson,
S. Balashov,
Yu. Mostovoy
Abstract:
We describe a beta electron spectrometer for use in an upcoming experiment that will measure the beta-antineutrino correlation coefficient (a-coefficient) in neutron beta decay. Electron energy is measured by a thick plastic scintillator detector. A conical array of plastic scintillator veto detectors is used to suppress events where the electron backscattered. A Monte Carlo simulation of this d…
▽ More
We describe a beta electron spectrometer for use in an upcoming experiment that will measure the beta-antineutrino correlation coefficient (a-coefficient) in neutron beta decay. Electron energy is measured by a thick plastic scintillator detector. A conical array of plastic scintillator veto detectors is used to suppress events where the electron backscattered. A Monte Carlo simulation of this device in the configuration of the a-coefficient experiment is presented. The design, construction, and testing of a full-scale prototype device is described. We discuss the performance of this spectrometer with respect to its suitability for the experiment.
△ Less
Submitted 21 January, 2004;
originally announced January 2004.
-
Measurement of the Neutron Lifetime Using a Proton Trap
Authors:
M. S. Dewey,
D. M. Gilliam,
J. S. Nico,
F. E. Wietfeldt,
X. Fei,
W. M. Snow,
G. L. Greene,
J. Pauwels,
R. Eykens,
A. Lamberty,
J. Van Gestel
Abstract:
We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime…
▽ More
We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime: tau_n = 886.8 +/- 1.2[stat] +/- 3.2[sys] seconds. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.
△ Less
Submitted 4 November, 2003;
originally announced November 2003.
-
Magnetic trap** of ultracold neutrons
Authors:
C. R. Brome,
J. S. Butterworth,
S. N. Dzhosyuk,
C. E. H. Mattoni,
D. N. McKinsey,
J. M. Doyle,
P. R. Huffman,
M. S. Dewey,
F. E. Wietfeldt,
R. Golub,
K. Habicht,
G. L. Greene,
S. K. Lamoreaux,
K. J. Coakley
Abstract:
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the l…
▽ More
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the liquid helium bath that results in a pulse of extreme ultraviolet light. This light is frequency downconverted to the visible and detected. Results are presented in which 500 +/- 155 neutrons are magnetically trapped in each loading cycle, consistent with theoretical predictions. The lifetime of the observed signal, 660 s +290/-170 s, is consistent with the neutron beta-decay lifetime.
△ Less
Submitted 13 March, 2001;
originally announced March 2001.
-
New Limit on the D Coefficient in Polarized Neutron Decay
Authors:
L. J. Lising,
S. R. Hwang,
J. M. Adams,
T. J. Bowles,
M. C. Browne,
T. E. Chupp,
K. P. Coulter,
M. S. Dewey,
S. J. Freedman,
B. K. Fujikawa,
A. Garcia,
G. L. Greene,
G. L. Jones,
H. P. Mumm,
J. S. Nico,
J. M. Richardson,
R. G. H. Robertson,
T. D. Steiger,
W. A. Teasdale,
A. K. Thompson,
E. G. Wasserman,
F. E. Wietfeldt,
R. C. Welsh,
J. F. Wilkerson
Abstract:
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contrib…
▽ More
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contributions to T violation due to leptoquarks. This paper presents details of the experiment, data analysis, and the investigation of systematic effects.
△ Less
Submitted 19 July, 2000; v1 submitted 1 June, 2000;
originally announced June 2000.
-
Magnetic Trap** of Neutrons
Authors:
P. R. Huffman,
C. R. Brome,
J. S. Butterworth,
K. J. Coakley,
M. S. Dewey,
S. N. Dzhosyuk,
R. Golub,
G. L. Greene,
K. Habicht,
S. K. Lamoreaux,
C. E. H. Mattoni,
D. N. McKinsey,
F. E. Wietfeldt,
J. M. Doyle
Abstract:
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap…
▽ More
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap. Neutral and charged particle traps are widely used tool for studying both composite and elementary particles, because they allow long interaction times and isolation from perturbing environments. Here we report the magnetic trap** of neutrons. The trap** region is filled with superfluid 4-He, which is used to load neutrons into the trap and as a scintillator to detect their decay. Neutrons have a lifetime in the trap of 750 +330/-200 seconds, mainly limited by their beta decay rather than trap losses. Our experiment verifies theoretical predictions regarding the loading process and magnetic trap** of neutrons. Further refinement of this method should lead to improved precision in the neutron lifetime measurement.
△ Less
Submitted 7 January, 2000;
originally announced January 2000.