Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the additio…
▽ More
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.
△ Less
Submitted 16 October, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Search for MeV Electron Recoils from Dark Matter in EXO-200
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total…
▽ More
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.
△ Less
Submitted 20 February, 2023; v1 submitted 2 July, 2022;
originally announced July 2022.
-
Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (81 additional authors not shown)
Abstract:
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on…
▽ More
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.
△ Less
Submitted 17 November, 2021; v1 submitted 3 September, 2021;
originally announced September 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (83 additional authors not shown)
Abstract:
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source d…
▽ More
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.
△ Less
Submitted 7 May, 2020; v1 submitted 31 January, 2020;
originally announced February 2020.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
Observation of single collisionally cooled trapped ions in a buffer gas
Authors:
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
D. S. Leonard,
A. Piepke,
C. Hargrove,
D. Sinclair,
V. Strickland,
W. Fairbank Jr.,
K. Hall,
B. Mong,
M. Moe,
J. Farine,
D. Hallman,
C. Virtue,
E. Baussan
, et al. (15 additional authors not shown)
Abstract:
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of…
▽ More
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.
△ Less
Submitted 5 July, 2007; v1 submitted 14 February, 2007;
originally announced February 2007.
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Authors:
EXO Collaboration,
F. LePort,
A. Pocar,
L. Bartoszek,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
M. Green,
T. Koffas,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
S. Waldman,
J. Wodin,
D. Woisard,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove
, et al. (20 additional authors not shown)
Abstract:
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
△ Less
Submitted 19 November, 2006;
originally announced November 2006.