-
An experimental search for an explanation of the difference between beam and bottle neutron lifetime measurements
Authors:
M. F. Blatnik,
L. S. Blokland,
N. Callahan,
J. H. Choi,
S. Clayton,
C. B Cude-Woods,
B. W. Filippone,
W. R. Fox,
E. Fries,
P. Geltenbort,
F. M. Gonzalez,
L. Hayen,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
A. Komives,
S Lin,
Chen-Yu Liu,
M. F. Makela,
C. L. Morris,
R. Musedinovic,
C. M. O'Shaughnessy,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat
, et al. (10 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently publi…
▽ More
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently published UCN aimed a searching for an explanation of this difference using the model proposed by Koch and Hummel.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment
Authors:
Nathan Callahan,
Chen-Yu Liu,
Francisco Gonzalez,
Evan Adamek,
James David Bowman,
Leah Broussard,
S. M. Clayton,
S. Currie,
C. Cude-Woods,
E. B. Dees,
X. Ding,
E. M. Egnel,
D. Fellers,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
R. W. Pattie Jr,
J. Ramsey
, et al. (15 additional authors not shown)
Abstract:
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neut…
▽ More
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trap** in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
New result for the neutron $β$-asymmetry parameter $A_0$ from UCNA
Authors:
M. A. -P. Brown,
E. B. Dees,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. Liu
, et al. (34 additional authors not shown)
Abstract:
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation…
▽ More
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $λ\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $λ\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.
△ Less
Submitted 14 August, 2018; v1 submitted 3 December, 2017;
originally announced December 2017.
-
Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection
Authors:
R. W. Pattie Jr.,
N. B. Callahan,
C. Cude-Woods,
E. R. Adamek,
L. J. Broussard,
S. M. Clayton,
S. A. Currie,
E. B. Dees,
X. Ding,
E. M. Engel,
D. E. Fellers,
W. Fox,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
C. -Y. Liu,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom
, et al. (13 additional authors not shown)
Abstract:
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay r…
▽ More
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.
△ Less
Submitted 7 February, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
First direct constraints on Fierz interference in free neutron $β$ decay
Authors:
K. P. Hickerson,
X. Sun,
Y. Bagdasarova,
D. Bravo-Berguño,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall,
S. D. Moore
, et al. (18 additional authors not shown)
Abstract:
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding…
▽ More
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.
△ Less
Submitted 8 July, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
A new method for measuring the neutron lifetime using an in situ neutron detector
Authors:
C. L. Morris,
E. R. Adamek,
L. J. Broussard,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
X. Ding,
W. Fox,
K. P. Hickerson,
A. T. Holley,
A. Komives,
C. -Y. Liu,
M. Makela,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
E. I. Sharapov,
S. K. Sjue,
Z. Tang,
J. Vanderwerp,
B. Vogelaar,
P. L. Walstrom
, et al. (6 additional authors not shown)
Abstract:
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron b…
▽ More
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.
△ Less
Submitted 14 October, 2016;
originally announced October 2016.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Determination of the Free Neutron Lifetime
Authors:
J. David Bowman,
L. J. Broussard,
S. M. Clayton,
M. S. Dewey,
N. Fomin,
K. B. Grammer,
G. L. Greene,
P. R. Huffman,
A. T. Holley,
G. L. Jones,
C. -Y. Liu,
M. Makela,
M. P. Mendenhall,
C. L. Morris,
J. Mulholland,
K. M. Nollett,
R. W. Pattie, Jr.,
S. Penttila,
M. Ramsey-Musolf,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
W. M. Snow,
A. Steyerl,
F. E. Wietfeldt
, et al. (2 additional authors not shown)
Abstract:
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve bot…
▽ More
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap
Authors:
D. J. Salvat,
E. R. Adamek,
D. Barlow,
L. J. Broussard,
J. D. Bowman,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
C. -Y. Liu,
M. Makela,
J. Medina,
D. J. Morley,
C. L. Morris,
S. I. Penttila,
J. Ramsey,
A. Saunders,
S. J. Seestrom,
S. K. L. Sjue,
B. A. Slaughter
, et al. (7 additional authors not shown)
Abstract:
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN los…
▽ More
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.
△ Less
Submitted 31 October, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.
-
The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
L. J. Broussard,
C. B. Cude-Woods,
Deion E Fellers,
Peter Geltenbort,
M. Hartl,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
C. M. Lavelle,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (6 additional authors not shown)
Abstract:
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the f…
▽ More
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.
△ Less
Submitted 12 August, 2013;
originally announced August 2013.
-
Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
Yelena Bagdasarova,
L. J. Broussard,
C. B. Cude-Woods,
Deon E Fellers,
Peter Geltenbort,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
D. G. Phillips,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (5 additional authors not shown)
Abstract:
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree bet…
▽ More
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.
-
Precision Measurement of the Neutron Beta-Decay Asymmetry
Authors:
M. P. Mendenhall,
R. W. Pattie Jr,
Y. Bagdasarova,
D. B. Berguno,
L. J. Broussard,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
S. D. Moore,
C. L. Morris
, et al. (16 additional authors not shown)
Abstract:
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, co…
▽ More
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.
△ Less
Submitted 19 February, 2013; v1 submitted 25 October, 2012;
originally announced October 2012.
-
Measurement of the neutron $β$-asymmetry parameter $A_0$ with ultracold neutrons
Authors:
UCNA Collaboration,
B. Plaster,
R. Rios,
H. O. Back,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
S. Currie,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
G. E. Hogan,
B. Hona,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
J. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall
, et al. (21 additional authors not shown)
Abstract:
We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then trans…
▽ More
We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T $2 \times 2π$ solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}$, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, $λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}$. Complete details of the analysis are presented.
△ Less
Submitted 25 July, 2012;
originally announced July 2012.
-
Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons
Authors:
UCNA Collaboration,
J. Liu,
M. P. Mendenhall,
A. T. Holley,
H. O. Back,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
S. Currie,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
G. E. Hogan,
B. Hona,
T. M. Ito,
C. -Y. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
C. L. Morris,
R. W. Pattie Jr.
, et al. (15 additional authors not shown)
Abstract:
A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of t…
▽ More
A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon $g_A/g_V = -1.27590_{-0.00445}^{+0.00409}$.
△ Less
Submitted 24 September, 2010; v1 submitted 21 July, 2010;
originally announced July 2010.
-
Demonstration of a solid deuterium source of ultra-cold neutrons
Authors:
A. Saunders,
J. M. Anaya,
T. J. Bowles,
B. W. Filippone,
P. Geltenbort,
R. E. Hill,
M. Hino,
S. Hoedl,
G. E. Hogan,
T. M. Ito,
K. W. Jones,
T. Kawai,
K. Kirch,
S. K. Lamoreaux,
C. -Y. Liu,
M. Makela,
L. J. Marek,
J. W. Martin,
C. L. Morris,
R. N. Mortensen,
A. Pichlmaier,
S. J. Seestrom,
A. Serebrov,
D. Smith,
W. Teasdale
, et al. (4 additional authors not shown)
Abstract:
Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined by the Fermi potential in material bottles, are playing an increasing role in measurements of fundamental properties of the neutron. The ability to manipulate UCN with material guides and bottles, magnetic fields, and gravity can lead to experiments with lower systematic errors than have been obtained in experiments with…
▽ More
Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined by the Fermi potential in material bottles, are playing an increasing role in measurements of fundamental properties of the neutron. The ability to manipulate UCN with material guides and bottles, magnetic fields, and gravity can lead to experiments with lower systematic errors than have been obtained in experiments with cold neutron beams. The UCN densities provided by existing reactor sources limit these experiments. The promise of much higher densities from solid deuterium sources has led to proposed facilities coupled to both reactor and spallation neutron sources. In this paper we report on the performance of a prototype spallation neutron-driven solid deuterium source. This source produced bottled UCN densities of 145 +/-7 UCN/cm3, about three times greater than the largest bottled UCN densities previously reported. These results indicate that a production UCN source with substantially higher densities should be possible.
△ Less
Submitted 18 December, 2003;
originally announced December 2003.
-
Measurements of ultracold neutron lifetimes in solid deuterium
Authors:
C. L. Morris,
J. M. Anaya,
T. J. Bowles,
B. W. Filippone,
P. Geltenbort,
R. E. Hill,
M. Hino,
S. Hoedl,
G. E. Hogan,
T. M. Ito,
T. Kawai,
K. Kirch,
S. K. Lamoreaux,
C. -Y. Liu,
M. Makela,
L. J. Marek,
J. W. Martin,
R. N. Mortensen,
A. Pichlmaier,
A. Saunders,
S. J. Seestrom,
D. Smith,
W. Teasdale,
B. Tipton,
M. Utsuro
, et al. (2 additional authors not shown)
Abstract:
We present the first measurements of the survival time of ultracold neutrons (UCNs) in solid deuterium SD2. This critical parameter provides a fundamental limitation to the effectiveness of superthermal UCN sources that utilize solid ortho-deuterium as the source material. Superthermal UCN sources offer orders of magnitude improvement in the available densities of UCNs, and are of great importan…
▽ More
We present the first measurements of the survival time of ultracold neutrons (UCNs) in solid deuterium SD2. This critical parameter provides a fundamental limitation to the effectiveness of superthermal UCN sources that utilize solid ortho-deuterium as the source material. Superthermal UCN sources offer orders of magnitude improvement in the available densities of UCNs, and are of great importance to fundamental particle-physics experiments such as searches for a static electric dipole moment and lifetime measurements of the free neutron. These measurements are performed utilizing a SD2 source coupled to a spallation source of neutrons, providing a demonstration of UCN production in this geometry and permitting systematic studies of the influence of thermal up-scatter and contamination with para-deuterium on the UCN survival time.
△ Less
Submitted 28 September, 2001; v1 submitted 27 September, 2001;
originally announced September 2001.