High-precision Penning-trap mass measurements of Cd and In isotopes at JYFLTRAP remove the fluctuations in the two-neutron separation energies
Authors:
A. Jaries,
M. Stryjczyk,
A. Kankainen,
L. Al Ayoubi,
O. Beliuskina,
P. Delahaye,
T. Eronen,
M. Flayol,
Z. Ge,
W. Gins,
M. Hukkanen,
D. Kahl,
S. Kujanpää,
D. Kumar,
I. D. Moore,
M. Mougeot,
D. A. Nesterenko,
S. Nikas,
H. Penttilä,
D. Pitman-Weymouth,
I. Pohjalainen,
A. Raggio,
W. Rattanasakuldilok,
A. de Roubin,
J. Ruotsalainen
, et al. (1 additional authors not shown)
Abstract:
We report on the first direct mass measurements of the $^{118,119}$Cd and $^{117-119}$In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The masses of $^{117}$In and $^{118}$Cd isotopes are in agreement with the literature, while $^{118,119}$In and $^{119}$Cd differ from literature by 49, 13 and 85 keV (6.1, 1.9 and 2…
▽ More
We report on the first direct mass measurements of the $^{118,119}$Cd and $^{117-119}$In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The masses of $^{117}$In and $^{118}$Cd isotopes are in agreement with the literature, while $^{118,119}$In and $^{119}$Cd differ from literature by 49, 13 and 85 keV (6.1, 1.9 and 2.1 standard deviations), respectively. The excitation energy of the $^{118}$In first isomeric state, $E_x = 40.3(25)$ keV, was determined for the first time. The updated mass values removed the fluctuations observed in the two-neutron separation energies and lead to a smoother linear decrease of both isotopic chains. The $\log(ft)$ value for the $^{118}$Cd decay is also found to increase from 3.93(6) to 4.089(8). The reported results indicate an absence of significant structural changes around $N=70$.
△ Less
Submitted 27 October, 2023; v1 submitted 29 August, 2023;
originally announced August 2023.
Precision mass measurement of $^{173}$Hf for nuclear structure of $^{173}$Lu and the $γ$ process
Authors:
A. Jaries,
M. Stryjczyk,
A. Kankainen,
T. Eronen,
Z. Ge,
M. Hukkanen,
I. D. Moore,
M. Mougeot,
A. Raggio,
W. Rattanasakuldilok,
J. Ruotsalainen
Abstract:
We report on the precise mass measurement of the $^{173}$Hf isotope performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The new mass-excess value, ${\mathrm{ME} = -55390.8(30)}$ keV, is in agreement with the literature while being nine times more precise. The newly determined $^{173}$Hf electron-capture $Q$ value,…
▽ More
We report on the precise mass measurement of the $^{173}$Hf isotope performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The new mass-excess value, ${\mathrm{ME} = -55390.8(30)}$ keV, is in agreement with the literature while being nine times more precise. The newly determined $^{173}$Hf electron-capture $Q$ value, $Q_{EC} = 1490.2(34)$ keV, allows us to firmly reject the population of an excited state at 1578 keV in $^{173}$Lu and 11 transitions tentatively assigned to the decay of $^{173}$Hf. Our refined mass value of $^{173}$Hf reduces mass-related uncertainties in the reaction rate of $^{174}$Hf$(γ,n)^{173}$Hf. Thus, the rate for the main photodisintegration destruction channel of the $p$ nuclide $^{174}$Hf in the relevant temperature region for the $γ$ process is better constrained.
△ Less
Submitted 24 December, 2023; v1 submitted 16 August, 2023;
originally announced August 2023.