Study of dielectric breakdown in liquid xenon with the XeBrA experiment
Authors:
J. Watson,
I. Olcina,
J. Soria,
D. N. McKinsey,
S. Kravitz,
E. E. Deck,
E. P. Bernard,
L. Tvrznikova,
W. L. Waldron,
Q. Riffard,
K. O'Sullivan
Abstract:
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment.…
▽ More
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a five-liter, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both anode current and photon rate was observed in the last 30 seconds leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler-Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.
△ Less
Submitted 31 October, 2022; v1 submitted 15 June, 2022;
originally announced June 2022.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Projected sensitivity of the LUX-ZEPLIN experiment to the $0νββ$ decay of $^{136}$Xe
Authors:
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley
, et al. (167 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 l…
▽ More
The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of $^{136}$Xe is projected to be 1.06$\times$10$^{26}$ years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with $^{136}$Xe at 1.06$\times$10$^{27}$ years.
△ Less
Submitted 24 April, 2020; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Search for neutrinoless double beta decay
Authors:
Igor Ostrovskiy,
Kevin O'Sullivan
Abstract:
We review current experimental efforts to search for neutrinoless double beta decay (0$νββ$). A description of the selected leading experiments is given and the strongest recent results are compared in terms of achieved background indexes and limits on effective Majorana mass. A combined limit is also shown. The second part of the review covers next generation experiments, highlighting the challen…
▽ More
We review current experimental efforts to search for neutrinoless double beta decay (0$νββ$). A description of the selected leading experiments is given and the strongest recent results are compared in terms of achieved background indexes and limits on effective Majorana mass. A combined limit is also shown. The second part of the review covers next generation experiments, highlighting the challenges and new technologies that may be necessary to achieve a justifiable discovery potential. A potential synergy with direct dark matter searches, which could be an especially prudent strategy in case the axial vector coupling constant is quenched in 0$νββ$ decay, is emphasized.
△ Less
Submitted 26 May, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.
-
Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski,
M. Dunford
, et al. (60 additional authors not shown)
Abstract:
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction o…
▽ More
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.
△ Less
Submitted 3 April, 2017; v1 submitted 31 May, 2015;
originally announced June 2015.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
Search for Neutrinoless Double-Beta Decay in $^{136}$Xe with EXO-200
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
C. G. Davis,
S. Delaquis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
A. Dolgolenko,
M. Dunford,
W. Fairbank Jr.,
J. Farine,
W. Feldmeier,
P. Fierlinger,
D. Franco
, et al. (53 additional authors not shown)
Abstract:
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana ma…
▽ More
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.
△ Less
Submitted 20 July, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials
Authors:
T. Brunner,
A. R. Mueller,
K. O'Sullivan,
M. C. Simon,
M. Kossick,
S. Ettenauer,
A. T. Gallant,
E. Mané,
D. Bishop,
M. Good,
G. Gratta,
J. Dilling
Abstract:
Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) poten…
▽ More
Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) potential the gate is open. Whereas former realizations of the device employ actual wires resulting in difficulties with winding, fixing and tensioning them, our approach is to use two grids photo-etched from a metallic foil. This design allows for simplified construction of gates covering large beam sizes up to at least 900\,mm$^2$ with variable wire spacing down to 250\,\textmu m. By changing the grids the wire spacing can be varied easily. A gate of this design was installed and systematically tested at TRIUMF's ion trap facility, TITAN, for use with radioactive beams to separate ions with different mass-to-charge ratios by their time-of-flight.
△ Less
Submitted 14 September, 2011; v1 submitted 20 July, 2011;
originally announced July 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Authors:
EXO Collaboration,
F. LePort,
A. Pocar,
L. Bartoszek,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
M. Green,
T. Koffas,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
S. Waldman,
J. Wodin,
D. Woisard,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove
, et al. (20 additional authors not shown)
Abstract:
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
△ Less
Submitted 19 November, 2006;
originally announced November 2006.
-
Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
Authors:
W. J. Bolte,
J. I. Collar,
M. Crisler,
J. Hall,
D. Holmgren,
D. Nakazawa,
B. Odom,
K. O'Sullivan,
R. Plunkett,
E. Ramberg,
A. Raskin,
A. Sonnenschein,
J. D. Vieira
Abstract:
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected…
▽ More
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected from Weakly Interacting Massive Particles can be obtained in conditions of near total insensitivity to minimum ionizing backgrounds. An understanding of the response of superheated heavy refrigerants to these recoils is demonstrated within the context of existing theoretical models. We comment on the prospects for the detection of supersymmetric dark matter particles with a large $CF_{3}I$ chamber.
△ Less
Submitted 17 March, 2005;
originally announced March 2005.